AHRI 620 I-P-2014 Performance Rating of Self-contained Humidifiers for Residential Applications.pdf
《AHRI 620 I-P-2014 Performance Rating of Self-contained Humidifiers for Residential Applications.pdf》由会员分享,可在线阅读,更多相关《AHRI 620 I-P-2014 Performance Rating of Self-contained Humidifiers for Residential Applications.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、 AHRI Standard 620 (I-P) 2014 Standard for Performance Rating of Self-contained Humidifiers for Residential Applications Price $10.00 (M) $20.00 (NM) Copyright 2014, by Air-Conditioning, Heating and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office IMPORT
2、ANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, a
3、ssembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. AHRI do
4、es not certify or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. Note: This standard supersedes AHRI Standard 620-2004. For SI ratings, see AHRI Standard 621 (SI)-2014. TABLE OF CONTENTS SECTION PAGE Section 1. Purpose .1 Section 2. Scope 1
5、 Section 3. Definitions1 Section 4. Classifications 2 Section 5. Test Requirements .2 Section 6. Rating Requirements 4 Section 7. Minimum Data Requirements for Published Ratings 4 Section 8. Operating Requirements 5 Section 9. Marking and Nameplate Data 5 Section 10. Conformance Conditions .5 APPEND
6、ICES Appendix A. References Normative .6 Appendix B. References Informative .6 AHRI STANDARD 620 (I-P)-2014 1 PERFORMANCE RATING OF SELF-CONTAINED HUMIDIFIERS FOR RESIDENTIAL APPLICATIONS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish for Self-contained Humidifiers: def
7、initions; classifications; test requirements; rating requirements; minimum data requirements for Published Ratings; operating requirements; marking and nameplate data; and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, engin
8、eers, installers, contractors and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to factory-made Self-contained Humidifiers for Residential Applications, as defined in Section 3. 2.1.1 Ener
9、gy Source. This standard applies to electrically operated Self-contained Humidifiers that are independent of the air stream of a central air system for moisture evaporation and distribution. 2.1.2 Installation. The Self-contained Humidifier is intended for installation through an interior wall. 2.2
10、Exclusions. This standard does not apply to the following: 2.2.1 Central system humidifiers as defined in AHRI Standard 610. 2.2.2 Portable humidifiers as defined in AHAM HU-1. 2.2.3 Humidifiers for commercial and industrial applications as defined in ANSI/AHRI Standard 640. Section 3. Definitions A
11、ll terms in this document will follow the standard industry definitions in the ASHRAE Wikipedia website (http:/wiki.ashrae.org/index.php/ASHRAEwiki) unless otherwise defined in this section. 3.1 Humidification Capacity. The capacity associated with a Humidifiers ability to add moisture to air expres
12、sed in gal/day of continuous operation. 3.2 Humidifier. A device designed to add moisture to air. 3.2.1 Self-contained Humidifiers for Residential Applications (Self-contained Humidifier). A class of Humidifier intended for non-ducted installation, but may be employed in ductwork, that is to be inst
13、alled with a water make-up line and/or drain, electrical service, and that is independent of a central air system. It may or may not be installed within the humidified space. 3.3 Published Rating. A statement of the assigned values of those performance characteristics, under stated Rating Conditions
14、, by which a unit may be chosen to fit its application. These values apply to all units of like nominal size and type (identification) produced by the same manufacturer. The term Published Rating includes the rating of all performance characteristics shown on the unit or published in specifications,
15、 advertising or other literature controlled by the manufacturer, at stated Rating Conditions. AHRI STANDARD 620 (I-P)-2014 2 3.3.1 Application Rating. A rating based on tests performed at application Rating Conditions (other than Standard Rating Conditions). 3.3.2 Standard Rating. A rating based on
16、tests performed at Standard Rating Conditions. 3.4 Rating Conditions. Any set of operating conditions under which a single level of performance results and which causes only that level of performance to occur. 3.4.1 Standard Rating Conditions. Rating Conditions used as the basis of comparison for pe
17、rformance characteristics. 3.5 “Shall“ or “Should“. “Shall“ or “should“ shall be interpreted as follows: 3.5.1 Shall. Where “shall“ or “shall not“ is used for a provision specified, that provision is mandatory if compliance with the standard is claimed. 3.5.2 Should. “Should“ is used to indicate pro
18、visions which are not mandatory but which are desirable as good practice. 3.6 Supplementary Heat. Heat used to enhance evaporation by heating the water and/or air for direct evaporation when the Humidifier is used in a recirculating system. 3.7 Wet-bulb and Dry-bulb Temperatures. Temperatures tt, an
19、d ttare the average of the test temperatures entering the test section immediately before entering the Self-contained Humidifier under test. Temperatures trand trare the rated temperatures at the same point. Section 4. Classifications 4.1 Self-contained Humidifiers within the scope of this standard
20、shall be classified according to the location of the evaporative process and the source of evaporative energy, as follows: 4.1.1 Within the unit without Supplementary Heat 4.1.2 External to unit without Supplementary Heat 4.1.3 Within the unit with Supplementary Heat 4.1.4 External to unit with Supp
21、lementary Heat Section 5. Test Requirements 5.1 Test Requirements. Published Ratings shall be verified by tests conducted in accordance with the test method described in ANSI/ASHRAE 164.2-2012 and at the rating conditions in Section 6, except as listed below: 5.1.1 Humidification Capacity The humidi
22、fication capacity shall be calculated using the following equation (in lieu of ANSI/ASHRAE 164.2 Equation 1): ( )tH-sHF1K=mH1 tt-ttrt-rt=F 2 Where: F = Temperature correction factor Hm= Humidification Capacity, gal/day Hs= Water supply rate, gal/day Ht= Waste water rate, gal/day AHRI STANDARD 620 (I
23、-P)-2014 3 K1= 1.000 tr= Return air Dry-bulb temperature at Rating Conditions, F tr= Return air Wet-bulb temperature at Rating Conditions, F tt= Return air Dry-bulb test temperature, F tt= Return air Wet-bulb test temperature, F 5.1.2 Observations and Conduct of Test. The method of testing shall be
24、in accordance with ANSI/ASHRAE 164.2 Section 7 and with the following test procedure outlined below: 5.1.2.1 Water Supply Source Adjustment. If the water quantity measuring apparatus prescribed in ANSI/ASHRAE 164.2 Section 7 does not permit supply water flow rate determination while the Self-contain
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI620IP2014PERFORMANCERATINGOFSELFCONTAINEDHUMIDIFIERSFORRESIDENTIALAPPLICATIONSPDF

链接地址:http://www.mydoc123.com/p-422558.html