AHRI 1330-2014 Performance Rating for Radiant Output of Gas Fired Infrared Heaters.pdf
《AHRI 1330-2014 Performance Rating for Radiant Output of Gas Fired Infrared Heaters.pdf》由会员分享,可在线阅读,更多相关《AHRI 1330-2014 Performance Rating for Radiant Output of Gas Fired Infrared Heaters.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、 2014 Standard for Performance Rating for Radiant Output of Gas Fired Infrared Heaters AHRI Standard 1330 Price $10.00 (M) $20.00 (NM) Copyright 2014, by Air-Conditioning, Heating, and Refrigeration Institute Printed in U.S.A. Registered United States Patent and Trademark Office IMPORTANT SAFETY DIS
2、CLAIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, assembled, inst
3、alled and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. AHRI does not certify
4、 or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. Note: This is a new standard. TABLE OF CONTENTS SECTION PAGE Section 1. Purpose 1 Section 2. Scope . 1 Section 3. Definitions . 1 Section 4. Test Requirements . 3 Section 5. Rating Requirem
5、ents 3 Section 6. Nomenclature . 4 Section 7. Minimum Data Requirements for Published Ratings 5 Section 8. Marking and Nameplate Data 5 Section 9. Conformance Conditions . 5 TABLES Table 1. Rating Requirements 4 Table 2. Nomenclature . 4 FIGURES Figure 1. Measuring Grid . 2 Figure 2. Radiation Refer
6、ence Plane 3 APPENDICES Appendix A. References Normative . 6 Appendix B. References Informative . 6 Appendix C. Method of Testing for Rating Infrared Heaters Normative . 7 Appendix D. Radiometer Source Normative 14 Appendix E. Radiometer Design Features Informative . 15 Appendix F. Radiant Heat Outp
7、ut Data - Informative 18 TABLES Table C1. Equipment Precision and Accuracy Requirements . 9 Table C2. Fuel Values. . 10 Table E1. Example of Measured Output During Calibration 17 FIGURES Figure C1. Radiation Reference Plane and Measuring Plane of a Horizontally Mounted High Intensity Infrared Heater
8、 . 8 Figure C2. Radiation Reference Plane and Measuring Plane of an Angle Mounted High Intensity Infrared Heater. 8 Figure C3. Measuring Plane of a Horizontally Mounted Low Intensity Infrared Heater 8 Figure C4. Measuring Plane of an Angle Mounted Low Intensity Infrared Heater . 8 Figure E1. Radiome
9、ter Design 15 Figure E2. Determination of the Calibration Factor 17 _AHRI STANDARD 1330-2014 1 PERFORMANCE RATING STANDARD FOR RADIANT OUTPUT OF GAS FIRED INFRARED HEATERS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish for infrared heaters: definitions; test requirement
10、s; rating requirements; nomenclature; minimum data requirements for Published Ratings; marking and nameplate data; and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors and users. 1.1.2 Review
11、 and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to Infrared Heaters that are Gas-Fired High-Intensity Infrared Heaters and Gas-Fired Low-Intensity Infrared Heaters with inputs up to and including 117.5 kW per
12、burner intended for installation in and heating of outdoor or indoor spaces. 2.1.1 Exclusions. This standard does not apply to heaters that do not radiate their energy into a single measuring plane. Section 3. Definitions All terms in this document will follow the standard industry definitions in th
13、e ASHRAE Terminology website (https:/www.ashrae.org/resources-publications/free-resources/ashrae-terminology) unless otherwise defined in this section. 3.1 Calibration Factor. The results of the calibration provided by an ISO 17025 accredited testing/calibration laboratory in the form of a calibrati
14、on factor consisting of a constant (a) and offset (b). 3.2 Gross Radiant Coefficient. Heat emitted by the appliance through the radiation reference plane divided by the gross heat input of the test gas. 3.3 Infrared Factor. A performance rating factor based on the gross radiant coefficient. Refer to
15、 Table 1. 3.4 Infrared Heater. A heater which directs a substantial amount of its energy output in the form of infrared energy into the area to be heated. Such heaters may be of either the vented or unvented type. The following are types of infrared heaters. 3.4.1 High-intensity Infrared Heater. An
16、infrared heater which has a radiating surface that typically operates at or above 732.0oC. 3.4.2 Low-intensity Infrared Heater. An infrared heater which has a radiating surface that typically operates at temperature less than 732.0oC. 3.4.2.1 Radiant Tube Infrared Heater. Typically, a low intensity
17、infrared heater in which combustion takes place within a tube or conduit. AHRI STANDARD 1330-2014_ 2 3.5 Measuring Cell. A measuring cell is defined as the area contained by four (4) adjacent nodal points of a measuring grid. 3.6 Measuring Plane. A plane parallel and below the radiation reference pl
18、ane. 3.7 Measuring Grid. Regular arrangement in the measuring plane of straight lines running parallel and perpendicular to the longitudinal axis of the appliance. Figure 1. Measuring Grid 3.8 Minimum Angle. The minimum installation angle specified by the manufacturer. The minimum angle is measured
19、from the horizontal plane. 3.9 Nodal Point/Node. A nodal point or node is the intersection of the perpendicular and parallel grid lines on the measuring plane, where an individual measurement is recorded. Four (4) adjacent nodal points confine a measuring cell. 3.10 Published Rating. A statement of
20、the assigned values of those performance characteristics, under stated Rating Conditions, by which a unit may be chosen to fit its application. These values apply to the model tested and identical models produced by the same manufacturer under different model numbers. The term Published Rating inclu
21、des the rating of all performance characteristics shown on the unit or published in specifications, advertising or other literature controlled by the manufacturer, at stated Rating Conditions. 3.10.1 Standard Rating. A rating based on tests performed at Standard Rating Conditions. 3.11 Radiation Ref
22、erence Plane. Flat surface bounded by the lower edge of the reflector or, in the case where radiant parts project below this lower edge of the reflector, the flat surface touching the lowest radiant part (refer to Figure 2). 3.12 Rating Conditions. Any set of operating conditions under which a singl
23、e level of performance results. (m,k) _AHRI STANDARD 1330-2014 3 Figure 2. Radiation Reference Plane 3.12.1 Standard Rating Conditions. Rating Conditions used as the basis of comparison for performance characteristics. 3.13 “Shall“ or “Should“. “Shall“ or “should“ shall be interpreted as follows: 3.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI13302014PERFORMANCERATINGFORRADIANTOUTPUTOFGASFIREDINFRAREDHEATERSPDF

链接地址:http://www.mydoc123.com/p-422499.html