AASHTO TP 117-2015 Standard Method of Test for Determination of the Voids of Dry Compacted Filler.pdf
《AASHTO TP 117-2015 Standard Method of Test for Determination of the Voids of Dry Compacted Filler.pdf》由会员分享,可在线阅读,更多相关《AASHTO TP 117-2015 Standard Method of Test for Determination of the Voids of Dry Compacted Filler.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Standard Method of Test for Determination of the Voids of Dry Compacted Filler AASHTO Designation: TP 117-151American Association of State Highway and Transportation Officials 444 North Capitol Street N.W., Suite 249 Washington, D.C. 20001 TS-2d TP 117-1 AASHTO Standard Method of Test for Determinat
2、ion of the Voids of Dry Compacted Filler AASHTO Designation: TP 117-1511. SCOPE 1.1. This document specifies the procedure for determining the voids of dry compacted filler by means of a Rigden Apparatus. This test allows for measuring the percent volume of free asphalt that a filler can carry. The
3、test is applicable to natural and manufactured fillers. 1.2. The values stated in SI units are to be regarded as the standard. 1.3. This standard does not purport to address all of the safety concerns associated with its use. It is the responsibility of the user of this standard to establish appropr
4、iate safety and health practices and to determine the applicability of regulatory limitations prior to use. 2. REFERENCED DOCUMENTS 2.1. ASTM Standards: D4753, Standard Guide for Evaluating, Selecting, and Specifying Balances and Standard Masses for Use in Soil, Rock, and Construction Materials Test
5、ing D5550, Standard Test Method for Specific Gravity of Soil Solids by Gas Pycnometer E145, Standard Specification for Gravity-Convection and Forced-Ventilation Ovens 2.2. Other: European Norm (EN) 1097-4: Determination of the voids of dry compacted filler 3. TERMINOLOGY 3.1. Definitions: 3.1.1. air
6、 voidsvolume of space in a filler occupied by air. 3.1.2. filleraggregate passing a 0.075-mm sieve. 4. SUMMARY OF TEST METHOD 4.1. This test allows for measuring the percent volume of free asphalt a filler can carry using the Rigden apparatus. 2015 by the American Association of State Highway and Tr
7、ansportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-2d TP 117-2 AASHTO 5. SIGNIFICANCE AND USE 5.1. This test allows for measuring the percent of voids in compacted filler that can be used in determination of the volume of free asphalt a filler can carry. 6. A
8、PPARATUS 6.1. The assembly of the Rigden apparatus is illustrated in Figure 1. Details of the system components are as follows: Figure 1Rigden Apparatus 6.1.1. Dropping block (1)A block containing a hollow cylinder with a flat, closed bottom: a) Inner diameter = 25.0 1 mm b) Inner height = 65 5 mm c
9、) Mass = 525 5 g 6.1.2. Plunger (2)Cylinder placed on top of filler sample: a) Length = 10 mm b) Mass = 350 1 g c) The plunger shall be provided with a circumferential groove 5 mm from its lower end to accommodate filler that works up the side of the cylinder while in use. This groove shall be 2 to
10、3 mm wide and 1 to 2 mm deep. Note 1The difference in diameter of the plunger and the inner diameter of the dropping block shall be 0.4 0.1 mm. (4) Tare Boring(2) Plunger(5) Pilot Bar(1) Dropping Block(3) Base Plate 2015 by the American Association of State Highway and Transportation Officials.All r
11、ights reserved. Duplication is a violation of applicable law.TS-2d TP 117-3 AASHTO 6.1.3. Base plate (3)Can be rectangular or circular: a) Minimum thickness = 20 mm b) Rectangular: Minimum length = 150 mm Minimum width = 100 mm c) Circular: Minimum diameter = 140 mm 6.1.4. Tare boring (4)Bore hole a
12、long the longitudinal axis of the plunger: a) Diameter = 1.6 0.1 mm b) Length = 10 mm 6.1.5. Pilot Bars (5): a) Must be exactly parallel preferably by the use of spacer(s). It may be necessary to use an additional bar in combination with a spacer mechanism to ensure that pilot bars are held exactly
13、parallel. b) The dropping height is indicated by a stop on the pilot bars. The maximum dropping height = 102 1 mm 6.1.6. Filter paper20 5 g/m2, 25 1 mm diameter. 6.1.7. Depth Caliper or Dial GaugeUsed to measure compacted filler height. Minimum resolution of 0.01 mm. 6.1.8. BalanceRequired to have a
14、 minimum capacity of 100 g with minimum accuracy of 0.2 g and Type I Readability of 0.01 g. A balance classified as GP2 in ASTM D4753 meets these requirements. 6.1.9. Forced-Draft OvenCapable of maintaining temperatures of at least 110 3C. Ovens designated as Type IIA or Type IIB in ASTM E145 meet t
15、his requirement. 7. SAMPLE PREPARATION 7.1. The test requires use of dry mineral filler. To ensure that there is no remaining moisture in the filler, spread at least 50 grams of filler in an appropriate-sized vessel and dry in a forced-draft oven at a temperature of 110 5C. Monitor sample mass at re
16、gular intervals and continue drying until a constant mass has been achieved, as indicated by no change in mass after consecutive readings taken at an interval of at least one hour. 7.2. After constant mass is achieved, remove the filler from the oven and allow it to cool to room temperature prior to
17、 testing. It is estimated that it is necessary to wait at least 90 minutes to allow filler to cool prior to testing. 8. PROCEDURE 8.1. Determine filler density according to ASTM D5550. 8.2. Cut filter paper to a diameter of 25 mm and insert it into the empty dropping block cylinder. This step is dep
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOTP1172015STANDARDMETHODOFTESTFORDETERMINATIONOFTHEVOIDSOFDRYCOMPACTEDFILLERPDF

链接地址:http://www.mydoc123.com/p-418394.html