1、Standard Method of Test for Thin-Walled Tube Sampling of Soils AASHTO Designation: T 207-121ASTM Designation: D1587-08 American Association of State Highway and Transportation Officials 444 North Capitol Street N.W., Suite 249 Washington, D.C. 20001 TS-1b T 207-1 AASHTO Standard Method of Test for T
2、hin-Walled Tube Sampling of Soils AASHTO Designation: T 207-121ASTM Designation: D1587-08 1. SCOPE 1.1. This method covers a procedure for using a thin-walled metal tube to recover relatively undisturbed soil samples suitable for laboratory tests of engineering properties, such as strength, compress
3、ibility, permeability, and density. Thin-walled tubes used in piston-, plug-, or rotary-type samplers, such as the Denison or Pitcher, must comply with the portions of this practice that describe the thin-walled tubes (Section 5.3). Note 1This method does not apply to liners used within the above sa
4、mplers. 1.2. Not all tubes specified in this method may be of sufficient diameter to perform all strength or consolidation testing. Refer to the appropriate test method for the minimum sample size to determine if the tube will be appropriate for that test. 1.3. The values stated in SI units are to b
5、e regarded as the standard. 1.4. This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns associated with its use. It is the responsibility of whoever uses this standard to establish appropriate safety and health p
6、ractices and determine the applicability of regulatory limitations prior to use. 2. REFERENCED DOCUMENTS 2.1. AASHTO Standard: R 13, Conducting Geotechnical Subsurface Investigations 2.2. ASTM Standard: D4220, Standard Practices for Preserving and Transporting Soil Samples 3. SUMMARY OF METHOD 3.1.
7、A relatively undisturbed sample is obtained by pressing a thin-walled metal tube into the in situ soil at the bottom of a boring, removing the soil-filled tube, and sealing the ends to prevent the soil from being disturbed or losing moisture. 4. SIGNIFICANCE AND USE 4.1. This method is used when it
8、is necessary to obtain a relatively undisturbed specimen suitable for laboratory tests of engineering properties or other tests that might be influenced by soil disturbance. 2015 by the American Association of State Highway and Transportation Officials.All rights reserved. Duplication is a violation
9、 of applicable law.TS-1b T 207-2 AASHTO 5. APPARATUS 5.1. Drilling EquipmentAny drilling equipment may be used that provides a reasonably clean hole, that minimizes disturbance of the soil to be sampled, and that does not hinder the penetration of the thin-walled sampler. Open borehole diameter and
10、the inside diameter of driven casing or hollow stem auger shall not exceed 3.5 times the outside diameter of the thin-walled tube. 5.2. Sampler Insertion Equipmentshall be adequate to provide a relatively rapid continuous penetration force. For hard formations it may be necessary, although not recom
11、mended, to drive the thin-walled tube sampler. 5.3. Sampler Headserves to couple the thin-walled tube to the insertion equipment and, together with the thin-walled tube, comprises the thin-walled tube sampler. The sampler head shall contain a suitable check valve and a venting area to the outside eq
12、ual to or greater than the area through the check valve. In some special cases, a check valve may not be required, but venting is required to avoid sample compression. Attachment of the head to the tube shall be concentric and coaxial to assure uniform application of force to the tube by the sampler
13、 insertion equipment. 5.4. Thin-Walled Tubesshould be manufactured as shown in Figure 1. They should have an outside diameter of 50.8 to 127.0 mm (2 to 5 in.) and be made of metal having adequate strength for use in the soil and formation intended. Tubes shall be clean and free of all surface irregu
14、larities including projecting weld seams. Other diameters may be used, but the tube dimensions should be proportional to the tube designs presented here. English Equivalents mm in. 9.52 3/812.7 1/225.4 1 50.8 2 88.9 31/2101.6 4 Figure 1Thin-Walled Tube for Sampling 2015 by the American Association o
15、f State Highway and Transportation Officials.All rights reserved. Duplication is a violation of applicable law.TS-1b T 207-3 AASHTO 5.4.1. Length of TubesSee Table 1 and Section 6.4. 5.4.2. Tolerancesshall be within the limits shown in Table 2. 5.4.3. Inside Clearance Ratioshould not be greater than
16、 1 percent or as specified by the engineer or geologist for the soil and formation to be sampled. Generally, the inside clearance ratio used should increase with the increase in plasticity of the soil being sampled, except for sensitive soils or where local experience indicates otherwise. See Figure
17、 1 for definition of inside clearance ratio. Table 1Suitable Thin-Walled Steel Sample TubesaOutside diameter: mm 50.8 76.2 127.0 in. 2 3 5 Wall thickness: BWG 18 16 11 mm 1.24 1.65 3.05 in. 0.049 0.065 0.120 Tube length: m 0.91 0.91 1.37 in. 36 36 54 Clearance: ratio, percent 1 1 1 aThe three diamet
18、ers recommended in Table 1 are indicated for purposes of standardization and are not intended to indicate that sampling tubes of intermediate or larger diameters are not acceptable. Lengths of tubes shown are illustrative. Proper lengths to be determined as suited to field conditions. Table 2Dimensi
19、onal Tolerances for Thin-Walled Tubes Nominal Tube Diameters from Table 1aTolerances Size Outside Diameter, mm 50.8 76.2 127 in. (2) (3) (5) Outside diameter: mm +0.18 +0.25 +0.38 in. (+0.007) (+0.010) (+0.015) mm 0.00 0.00 0.00 in. (0.000) (0.000) (0.000) Inside diameter: mm +0.00 +0.00 +0.00 in. (
20、+0.000) (+0.000) (+0.000) mm 0.18 0.25 0.38 in. (0.007) (0.010) (0.015) Wall thickness: mm 0.18 0.25 0.38 in. (0.007) (0.010) (0.015) Ovality:bmm 0.38 0.51 0.76 in. (0.015) (0.020) (0.030) Straightness: mm/m 2.5 2.5 2.5 in./ft (0.030) (0.030) (0.030) aIntermediate or larger diameters should be propo
21、rtional. Tolerances shown are essentially standard commercial manufacturing tolerances for seamless steel mechanical tubing. Specify only two of the first three tolerances: that is, OD and ID, or OD and Wall, or ID and Wall. bOvalitythe cross section of the tube that deviates from a perfect circle.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOT2072012STANDARDMETHODOFTESTFORTHINWALLEDTUBESAMPLINGOFSOILSPDF

链接地址:http://www.mydoc123.com/p-418150.html