AASHTO HB-17 DIVISION II SEC 10-2002 Division II Construction - Prestressing (Errata 01 2003)《预应力》.pdf
《AASHTO HB-17 DIVISION II SEC 10-2002 Division II Construction - Prestressing (Errata 01 2003)《预应力》.pdf》由会员分享,可在线阅读,更多相关《AASHTO HB-17 DIVISION II SEC 10-2002 Division II Construction - Prestressing (Errata 01 2003)《预应力》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Section 10 PRESTRESSING 10.1 GENERAL 10.1.1 Description This work shall consist of prestressing precast or cast- in-place concrete by furnishing, placing, and tensioning of prestressing steel in accordance with details shown on the plans, and as specified in these specifications and the spe- cial pr
2、ovisions. It includes prestressing by either the pre- tensioning or post-tensioning methods or by a combina- tion of these methods. This work shall include the furnishing and installation of any appurtenant items necessary for the particular pre- stressing system to be used, including but not limite
3、d to ducts, anchorage assemblies and grout used for pressure grouting ducts. For cast-in-place prestressed concrete, the term “mem- ber” as used in this section shall be considered to mean the concrete which is to be prestressed. When members are to be constructed with part of the reinforcement pret
4、ensioned and part post-tensioned, the applicable requirement of this Specification shall apply to each method. 10.1.2 Details of Design When the design for the prestressing work is not fully detailed on the plans, the Contractor shall determine the details or type of prestressing system for use and
5、select materials and details conforming to these Specifications as needed to satisfy the prestressing requirements speci- fied. The system selected shall provide the magnitude and distribution of prestressing force and ultimate strength re- quired by the plans without exceeding allowable tempo- rary
6、 stresses. Unless otherwise shown on the plans, all de- sign procedures, coefficients and allowable stresses, friction and prestress losses as well as tendon spacing and clearances shall be in accordance with the Division I, De- sign, of the AASHTO Standard Specifications for High- way Bridges. The
7、prestressing may be performed by either preten- sioning or post-tensioning methods unless the plans show only pretensioning details. If the plans show only preten- sioning details, the use of a post-tensioning system will be allowed only if complete details of any necessary modifi- cations are appro
8、ved by the Engineer. When the effective or working force or stress is shown on the plans, it shall be considered to be the force or stress remaining in the prestressing steel after all losses, including creep and shrinkage of concrete, elastic short- ening of concrete, relaxation of steel, friction
9、and take up or seating of anchorages, and all other losses peculiar to the method or system of prestressing have taken place or have been provided for. When the jacking force is shown on the plans, it shall be considered to be the force applied to the tendon prior to anchorage and the occurrence of
10、any losses, including the anchor set loss. 10.2 SUPPLEMENTARY DRAWINGS 10.2.1 Working Drawings Whenever the plans do not include complete details for a prestressing system and its method of installation, or when complete details are provided in the plans and the Contractor wishes to propose any chan
11、ge, the Contractor shall prepare and submit to the Engineer working draw- ings of the prestressing system proposed for use. Fabrica- tion or installation of prestressing material shall not begin until the Engineer has approved the drawings. The working drawings of the prestressing system shall show
12、complete details and substantiating calculations of the method, materials and equipment the Contractor pro- poses to use in the prestressing operations, including any additions or rearrangement of reinforcing steel and any re- vision in concrete dimensions from that shown on the plans. Such details
13、shall outline the method and sequence of stressing and shall include complete specifications and details of the prestressing steel and anchoring devices, working stresses, anchoring stresses, tendon elongations, type of ducts, and all other data pertaining to the pre- stressing operation, including
14、the proposed arrangement of the prestressing steel in the members. Working drawings shall be submitted sufficiently in advance of the start of the affected work to allow time for 553 554 HIGHWAY BRIDGES 10.2.1 review by the Engineer and correction by the Contractor of the drawings without delaying t
15、he work. 10.2.2 Composite Placing Drawings When required by the special provisions, in addition to all required working drawings, the Contractor shall prepare composite placing drawings to scale and in suf- ficient detail to show the relative positions of all items that are to be embeddedin the conc
16、rete, and their em- bedment depth, for the portions of the structure that are to be prestressed. Such embedded items include the pre- stressing ducts, vents, anchorage reinforcement and hard- ware, reinforcing steel, anchor bolts, earthquake restrain- ers, deck joint seal assemblies, drainage system
17、s, utility conduits and other such items. Such drawings shall be ad- equate to ensure that there will be no conflict between the planned positions of any embedded items and that con- crete cover will be adequate. If during the preparation of such drawings conflicts are discovered, the Contractor sha
18、ll revise his or her working drawing for one or more of the embedded items or propose changes in the dimen- sions of the work as necessary to eliminate the conflicts or provide proper cover. Any such revisions shall be ap- proved by the Engineer before work on any affected item is started. All costs
19、 involved with the preparation of such drawings and with making the necessary modifications to the work resulting therefrom shall be borne by the Contractor. 10.3 MATERIALS 10.3.1 Prestressing Steel and Anchorages Prestressing reinforcement shall be high-strength seven-wire strand, high-strength ste
20、el wire, or high- strength alloy bars of the grade and type called for on the plans or in the special provisions and shall conform to the requirements of the following specifications. 10.3.1.1 Strand Uncoated seven-wire strand shall conform to the requirements of AASHTO M 203 (ASTM A 416). Supplemen
21、t S 1 (Low-Relaxation) shall apply when specified. 10.3.1.2 Wire Uncoated stress-relieved steel wire shall conform to the requirements of AASHTO M 204 (ASTM A 421). 10.3.1.3 Bars Uncoated high-strength bars shall conform to the re- quirements of AASHTO M 275 (ASTM A 722). Bars with greater minimum u
22、ltimate strength, but otherwise pro- duced and tested in accordance with AASHTO M 275 (ASTM A 722), may be used provided they have no prop- erties that make them less satisfactory than the specified material. 10.3.2 Post-Tensioning Anchorages and Couplers All anchorages and couplers shall develop at
23、 least 95% of the actual ultimate strength of the prestressing steel, when tested in an unbonded state, without exceeding an- ticipated set. The coupling of tendons shall not reduce the elongation at rupture below the requirements of the ten- don itself. Couplers and/or coupler components shall be e
24、nclosed in housings long enough to permit the necessary movements. Couplers for tendons shall be used only at lo- cations specifically indicated and/or approved by the En- gineer. Couplers shall not be used at points of sharp ten- don curvature. 10.3.2.1 Bonded Systems Bond transfer lengths between
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOHB17DIVISIONIISEC102002DIVISIONIICONSTRUCTIONPRESTRESSINGERRATA012003 预应力 PDF

链接地址:http://www.mydoc123.com/p-417576.html