1、Section 4 ANALYSIS REQUIREMENTS 4.1 GENERAL The requirements of this section shall control the se- lection and method of seismic analysis of bridges. Four analysis procedures are presented. Procedure 1. Uniform Load Method Procedure 2. Single-Mode Spectral Method Procedure 3. Multimode Spectral Meth
2、od Procedure 4. Time History Method In each method, ali fixed column, pier, or abutment supports are assumed to have the same ground motion at the same instant in time. At movable supports, displace- ments determined from the analysis prescribed in this chapter, which exceed the minimum seat width r
3、equire- ments as specified in Article 6.3 or 7.3, shall be used in design without reduction by the Response Modification Factor (Article 3.7). 4.2 SELECTION OF ANALYSIS METHOD Minimum requirements for the selection of an analysis method for a particular bridge type are given in Table 4.2A. Applicabi
4、lity is determined by the “regularity” of a bridge which is a function of the number of spans and the distribution of weight and stiffness. Regular bridges have less than seven spans, no abrupt or unusual changes in weight, stiffness, or geometry and no large changes in these parameters from span-to
5、-span or support-to-support (abutments excluded). They are defined in Table 4.2B. Any bridge not satisfying the requirements of Table 4.2B TABLE 4.2A Minimum Analysis Requirements Seismic Regular Bridges Not Regular Performance with Bridges with Category 2 Through 6 Spans 2 or More Spans A Not requi
6、red Not required B, C, D Use Procedure Use Procedure 1 or 2 3 is considered to be “not regular.” A more rigorous, gener- ally accepted analysis procedure may be used in lieu of the recommended minimum such as the Time History Method (Procedure 4). Curved bridges comprised of multiple simple spans sh
7、all be considered to be “not regular” bridges if the sub- tended angle in plan is greater than 20”; such bridges shall be analyzed by either Procedure 3 or 4. 4.2.1 Special Requirements for Single-Span Bridges and Bridges in SPC A Notwithstanding the above requirements, detailed seis- mic analysis i
8、s not required for a single-span bridge or for bridges classified as SPC A. 4.2.2 Special Requirements for Curved Bridges A curved continuous-girder bridge may be analyzed as if it were straight provided all of the following require- ments are satisfied: (a) the bridge is regular as defined in Table
9、 4.2B ex- cept that for a two-span bridge the maximum span length ratio from span-to-span must not exceed 2; (b) the subtended angle in plan is not greater than 30”; and TABLE 4.2B Regular Bridge Requirements Parameter Value Number of Spans 23456 Maximum subtended 90” 90” 90” 90” 90” Maximumspanleng
10、th 3 2 2 1.5 1.5 angle (curved bridge) ratio from span-to-span stiffness ratio from span-to-span (excluding abutments) Maximum bentlpier - 4432 Note: All ratios expressed in terms of the smaller value. 453 454 HIGHWAY BRIDGES 4.2.2 (c) the span lengths of the equivalent straight bridge are equal to
11、the arc lengths of the curved bridge. If these requirements are not satisfied, then curved con- tinuous-girder bridges must be analyzed using the actual curved geometry. 4.2.3 Special Requirements for Critical Bridges More rigorous methods of analysis are required for cer- tain classes of important
12、bridges which are considered to be critical structures (e.g., those that are major structures in size and cost or perform a criticai function), andor for those that are geometrically complex and close to active earthquake faults. Time history methods of analysis are recommended for this purpose, pro
13、vided care is taken with both the modeling of the structure and the selection of the input time histories of ground acceleration. Time history methods of analysis are described in Article 4.6. 4.3 UNIFORM LOAD METHOD- PROCEDURE 1 The uniform load method, described in the following steps, may be used
14、 for both transverse and longitudinal earthquake motions. It is essentially an equivalent static method of analysis which uses a uniform lateral load to approximate the effect of seismic loads. The method is suitable for regular bridges that respond principally in their fundamental mode of vibration
15、. Whereas ail dis- placements and most member forces are calculated with good accuracy, the method is known to overestimate the transverse shears at the abutments by up to 100%. If such conservatism is undesirable then the single mode spectral analysis method (Procedure 2) is recommended. Step 1. Ca
16、lculate the static displacements v,(x) due to an assumed uniform load po as shown in Figure 4.4A and Figure 4.4B. The uniform loading po is applied over the length of the bridge; it has units of forcelunit length and may be arbitrarily set equal to 1.0. The static displacement v,(x) has units of len
17、gth. Step 2. Calculate the bridge lateral stiffness, K, and total weight, W, from the following expressions: (4 - 1) (4 - 2) K=- POL VS,MAX W = I w(x)dx where L = total length of the bridge vs, MAX = maximum value of v,(x) and w(x) = weight per unit length of the dead load of the bridge superstructu
18、re and tributary substructure The weight should take into account structural ele- ments and other relevant loads including, but not limited to, pier caps, abutments, columns and footings. Other loads such as live loads may be included. (Generally, the inertia effects of live loads are not included i
19、n the analy- sis; however, the probability of a large live load being on the bridge during an earthquake should be considered when designing bridges with high live-to-dead load ratios which are located in metropolitan areas where traffic con- gestion is likely to occur.) Step 3. Calculate the period
20、 of the bridge, T, using the expression: T=2z - (4 - 3) where g = acceleration of gravity (length/time2) Step 4. Calculate the equivalent static earthquake loading pe from the expression: (4 - 4) where C, = the dimensionless elastic seismic response coefficient given by Equation (3-1) pe = equivalen
21、t uniform static seismic loading per unit length of bridge applied to repre- sent the primary mode of vibration. Step 5. Calculate the displacements and member forces for use in design either by applying pe to the struc- ture and performing a second static analysis or by scaling the results of Step
22、1 by the ratio pJpo. 4.4 SINGLE MODE SPECTRAL ANALYSIS METHOD-PROCEDURE 2 The single mode spectral analysis method described in the following steps may be used for both transverse and longitudinal earthquake motions. Examples illustrating its application are given in the Commentary. Step 1. Calculat
23、e the static displacements v,(x) due to an assumed uniform loading p, as shown in Figure 4.4A. 4.2.2 DIVISION IA-SEISMIC DESIGN 455 FIGURE 4.4A Bridge Deck Subjected to Assumed Transverse and Longitudinal Loading The uniform loading po is applied over the length of the bridge; it has units of forceh
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AASHTOHB17DIVISIONIASEC42002DIVISIONIASEISMICDESIGNANALYSISREQUIREMENTS 设计 分析 要求 PDF

链接地址:http://www.mydoc123.com/p-417570.html