API MPMS 6.1-1991 Manual of Petroleum Measurement Standards Chapter 6 - Metering Assemblies Section 1 - Lease Automatic Custody Transfer (LACT) Systems (Second Edition)《石油计量标准手册.第6.pdf
《API MPMS 6.1-1991 Manual of Petroleum Measurement Standards Chapter 6 - Metering Assemblies Section 1 - Lease Automatic Custody Transfer (LACT) Systems (Second Edition)《石油计量标准手册.第6.pdf》由会员分享,可在线阅读,更多相关《API MPMS 6.1-1991 Manual of Petroleum Measurement Standards Chapter 6 - Metering Assemblies Section 1 - Lease Automatic Custody Transfer (LACT) Systems (Second Edition)《石油计量标准手册.第6.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Manual of PetroleumMeasurement StandardsChapter 6Metering AssembliesSection 1Lease Automatic Custody Transfer (LACT) SystemsSECOND EDITION, MAY 1991REAFFIRMED, MAY 2012Manual of PetroleumMeasurement StandardsChapter 6Metering AssembliesSection 1Lease Automatic Custody Transfer(LACT) SystemsMeasureme
2、nt CoordinationSECOND EDITION, MAY 1991REAFFIRMED, MAY 2012SPECIAL NOTES1. API PUBLICATIONS NECESSARILY ADDRESS PROBLEMS OF A GENERALNATURE. WITH RESPECT TO PARTICULAR CIRCUMSTANCES, LOCAL, STATE,AND FEDERAL LAWS AND REGULATIONS SHOULD BE REVIEWED.2. API IS NOT UNDERTAKING TO MEET THE DUTIES OF EMPL
3、OYERS,MANUFACTURERS, OR SUPPLIERS TO WARN AND PROPERLY TRAIN ANDEQUIP THEIR EMPLOYEES, AND OTHERS EXPOSED, CONCERNING HEALTHAND SAFETY RISKS AND PRECAUTIONS NOR UNDERTAKING THEIR OBLIGA TIONS UNDER LOCAL, STATE, OR FEDERAL LAWS.3. INFORMATION CONCERNING SAFETY AND HEALTH RISKS AND PROPERPRECAUTIONS
4、WITH RESPECT TO PARTICULAR MATERIALS AND CONDI TIONS SHOULD BE OBTAINED FROM THE EMPLOYER, THE MANUFACTUREROR SUPPLIER OF THAT MATERIAL, OR THE MATERIAL SAFETY DATA SHEET.4. NOTHING CONTAINED IN ANY API PUBLICATION IS TO BE CONSTRUED ASGRANTING ANY RIGHT, BY IMPLICATION OR OTHERWISE, FOR THEMANUFACT
5、URE, SALE, OR USE OF ANY METHOD, APPARATUS, OR PRODUCTCOVERED BY LETTERS PATENT. NEITHER SHOULD ANYTHING CONTAINEDIN THE PUBLICATION BE CONSTRUED AS INSURING ANYONE AGAINSTLIABILITY FOR INFRINGEMENT OF LETTERS PATENT.5. GENERALLY, API STANDARDS ARE REVIEWED AND REVISED, REAF FIRMED, OR WITHDRAWN AT
6、LEAST EVERY FIVE. YEARS. SOMETIMES AONE-TIME EXTENSION OF UP TO TWO YEARS WILL BE ADDED TO THISREVIEW CYCLE. THIS PUBLICATION WILL NO LONGER BE IN EFFECT AS ANOPERATIVE API STANDARD FIVE YEARS AFTER ITS PUBLICATION DATE OR,WHERE AN EXTENSION HAS BEEN GRANTED, UPON REPUBLICATION. THESTATUS OF THE PUB
7、LICATION CAN BE ASCERTAINED FROM THE APIAUTHORING DEPARTMENT (TELEPHONE 202 682-8000). A CATALOG OF APIPUBLICATIONS AND MATERIALS IS PUBLISHED ANNUALLY AND UPDATEDQUARTERLY BY API, 1220 L STREET, N.W., WASHINGTON, D.C. 20005.Copyright 1991 American Petroleum InstituteFOREWORDThis publication covers
8、the design, installation,calibrationand operation of leaseautomatic custody transfer (LACT) systems.API publications may be used by anyone desiring to do so. Every effort has been madeby the Institute to assure the accuracy and reliability ofthe data contained in them; however,the Institute makes no
9、 representation, warranty, or guarantee in connection with thispublication and hereby expressly disclaims any liability or responsibility for loss or damageresulting from its use or for the violation ofany federal, state, or municipal regulation withwhich this publication may conflict.Suggested revi
10、sions are invited and should be submitted to the director ofthe Measure ment Coordination Department, American Petroleum Institute, 1220 L Street, N.W.,Washington, D.C. 20005.iii11111111111111111111111111111111111CONTENTSPageSECTION I-LEASE AUTOMATIC CUSTODY TRANSFER(LACT) SYSTEMS6.1.1 Introduction
11、16.1.1.1 Compliance 16.1.1.2 Future Developments , 16.1.2 Scope_“ 16.1.3 Field of Application “ , 16.1.4 Referenced Publications 16.1.5 Requirements for All LACT Systems 16.1.5.1 Sampling _ : : 26.1.5.2 Maintaining Allowables 26.1.5.3 Monitoring Quality 36.1.6 Displacement and Turbine Meter LACT Sys
12、tems .36.1.6.1 Installation .36.1.6.2 Specific Requirements .36.1.6.3 Facilities and Procedures for Proving Displacementand Turbine Meters .36.1.6.4 Displacement and Turbine Meter System Operation 56.1.6.5 Nonmerchantable Oil Interruption 5FigureI-Typical Displacement or Turbine MeterLACT Unit Schem
13、atic Diagram .4vChapter 6-Metering AssembliesSECTION 1-LEASE AUTOMATIC CUSTODY TRANSFER (LACT) SYSTEMS6.1.1 IntroductionThis publication has been prepared as a guide for thedesign, installation, calibration, and operation ofa lease auto matic custody transfer (LACT) system.A LACT system is an arrang
14、ement ofequipment designedfor the unattended custody transfer of liquid hydrocarbonsfrom producing leases to the transporting carrier. The systemmust determine net volume and quality, provide for fail-safeand tamperproof operation, and meet requirements of ac curacy and dependability as agreed to by
15、 mutually concernedparties, such as the producer, the transporter, the royaltyowner, and federal, state, and municipal regulatorybodies.6.1.1.1 COMPLIANCECompliance with the provisions ofthis standard may resultin an approach to accuracy or may establish safeguards thatare not necessary under all co
16、nditions. When not required,those portions ofthis standard not considered applicable maybe disregarded with the mutual agreement ofall parties con cerned. The compulsory verb form shall,“ while not neces sarily binding for all conditions, has been used when adeviation from the standard is likely to
17、adversely affect thesatisfactory operation of a system that is designed for op timum operation under typical producing conditions.6.1.1.2 FUTURE DEVELOPMENTSAlthough this standard presents the concurrence of theindustry on system requirements for lease automatic custodytransfer, it is not intended i
18、n any way to restrict futuredevelopments. Equipment now exists in the design or field proving stages that may further improve the art of leaseautomatic custody transfer. The industry encourages suchdevelopments, and when concerned parties mutually agreeto use such systems or components, every effort
19、 should bemade to expedite their use and standardization.6.1.2 ScopeThis publication describes the metering function of aLACT unit and is intended to complement API SpecificationII N,Specificationfor Lease Automatic Custody Transfer(LACT) Equipment. LACT equipment includes a meter(either displacemen
20、t or turbine), a proving system (eitherfixed or portable), devices for determining temperatureand pressure and for sampling the liquid, and a meansofdetermining nonmerchantable oil. Many ofthe aspectsof the metering function of a LACT unit are considered atlength in other parts of this manual and ar
21、e referencedin 6.1.4.6.1.3 Field of ApplicationThe field of application of this publication is the unat tended and automatic measurement by meter ofhydrocarbonliquids produced in the field and transferred to a pipeline ineither a scheduled or a nonscheduled operation.Note: The information contained
22、in Chapter 6.7 should also be con sidered when measuring viscous fluids by meter.6.1.4 Referenced PublicationsMany ofthe aspects ofthe metering function are discussedat length in other parts of this manual. Please refer to thefollowing chapters for more information.APIManual ofPetroleum Measurement
23、StandardsChapter 4-“Proving Systems“Chapter 5.1, “General Considerations forMeasurement by Meters“Chapter 5.2, “Measurement of LiquidHydrocarbons by Displacement Meters“Chapter 5.3, “Measurement of LiquidHydrocarbons by Turbine Meters“Chapter 6.7, “Metering Viscous Hydrocar bons“Chapter 7-“Temperatu
24、re Determination“Chapter 8-“Sampling“Chapter 8.2, “Automatic Sampling ofPetroleum and Petroleum Products“Chapter 9-“Density Determination“Chapter 1O-“Sediment and Water“Chapter 12.2, “Calculation of LiquidPetroleum Quantities Measured by Turbineor Displacement Meters“Spec lIN Specification for Lease
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- APIMPMS611991MANUALOFPETROLEUMMEASUREMENTSTANDARDSCHAPTER6METERINGASSEMBLIESSECTION1LEASEAUTOMATICCUSTODYTRANSFERLACTSYSTEMSSECONDEDITION

链接地址:http://www.mydoc123.com/p-399651.html