BS PD CLC TS 50131-12-2016 Alarm systems Intrusion and hold-up systems Methods and requirements for setting and unsetting of Intruder Alarm Systems (IAS)《警报系统 入侵和滞留报警系统 侵入.pdf
《BS PD CLC TS 50131-12-2016 Alarm systems Intrusion and hold-up systems Methods and requirements for setting and unsetting of Intruder Alarm Systems (IAS)《警报系统 入侵和滞留报警系统 侵入.pdf》由会员分享,可在线阅读,更多相关《BS PD CLC TS 50131-12-2016 Alarm systems Intrusion and hold-up systems Methods and requirements for setting and unsetting of Intruder Alarm Systems (IAS)《警报系统 入侵和滞留报警系统 侵入.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、PD CLC/TS 50131-12:2016 Alarm systems Intrusion and hold-up systems Part 12: Methods and requirements for setting and unsetting of Intruder Alarm Systems (IAS) BSI Standards Publication WB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06PD CLC/TS 50131-12:2016 PUBLISHED DOCUMENT National forewo
2、rd This Published Document is the UK implementation of CLC/TS 50131-12:2016. The UK participation in its preparation was entrusted to Technical Committee GW/1/2, Installed Alarm Systems. A list of organizations represented on this committee can be obtained on request to its secretary. This publicati
3、on does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2016. Published by BSI Standards Limited 2016 ISBN 978 0 580 92973 1 ICS 13.320 Compliance with a British Standard cannot confer immunity fr
4、om legal obligations. This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 November 2016. Amendments/corrigenda issued since publication Date Text affectedPD CLC/TS 50131-12:2016TECHNICAL SPECIFICATION SPCIFICATION TECHNIQUE TECHNISCHE SPEZIFIK
5、ATION CLC/TS 50131-12 November 2016 ICS 13.320 English Version Alarm systems - Intrusion and hold-up systems - Part 12: Methods and requirements for setting and unsetting of Intruder Alarm Systems (IAS) To be completed Alarmanlagen - Einbruch- und berfallmeldeanlagen - Teil 12: Methoden und Anforder
6、ungen zur Scharf- und Unscharfschaltung von Einbruchmeldeanlagen (EMA) This Technical Specification was approved by CENELEC on 2016-07-25. CENELEC members are required to announce the existence of this TS in the same way as for an EN and to make the TS available promptly at national level in an appr
7、opriate form. It is permissible to keep conflicting national standards in force. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece,
8、 Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrote
9、chnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. CLC/TS 50131-12:2016 E PD CLC/TS 50131-12:2016 Contents Page
10、 European foreword . 3 Introduction 4 1 Scope . 5 2 Normative references . 5 3 Terms and definitions 5 4 Methods of setting and unsetting . 6 4.1 General . 6 4.2 Methods of setting 6 4.3 Methods of unsetting . 7 5 Documentation 8 Annex A (normative) Equipment specifications 9 Annex B (informative) S
11、chematic example for entry door 10 Annex C (normative) Equipment test procedures . 11 CLC/TS 50131-12:2016PD CLC/TS 50131-12:2016 European foreword This document (CLC/TS 50131-12:2016) has been prepared by CLC/TC 79 “Alarm systems“. Attention is drawn to the possibility that some of the elements of
12、this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. CLC/TS 50131-12:2016PD CLC/TS 50131-12:2016 Introduction Unwanted alarms have been a significant problem for response authorities throughout Europe. A si
13、gnificant proportion of these are attributed to “operator error” during the entry and exit procedures. Recommendations are therefore made for the selection of methods of setting and unsetting an Intrusion Alarm System (IAS) that will minimize such errors. CLC/TS 50131-12:2016PD CLC/TS 50131-12:2016
14、1 Scope This Technical Specification provides recommendations for those methods of setting and unsetting an Intrusion Alarm System (IAS) complying with EN 50131-1 that will reduce unwanted alarms arising from “operator error” in setting and unsetting the IAS and provide confidence that the condition
15、s in which the system is installed are conducive to system reliability during the “set” period. This document details optional methods by which these goals may be achieved, either in isolation, or in conjunction with verification methods. These recommendations should be incorporated into the respect
16、ive standards in the EN 50131 series. This Technical Specification also provides (in Annex A) recommendations for equipment and (in Annex C) associated test requirements, in order to permit the manufacture of standardized equipment to provide the functionality needed by an IAS to meet these recommen
17、dations. NOTE This standard includes requirements that are additional to those in EN 50131-1 which are relevant when the respective method of setting and unsetting is implemented. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are
18、 indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 50131-1:2006, Alarm systems Intrusion and hold-up systems Part 1: System requirements CLC/TS 50131-2-
19、10:2014, Alarm systems Intrusion and hold-up systems Part 2-10: Intrusion detectors Lock state contacts (magnetic) EN 50131-3:2009, Alarm systems Intrusion and hold-up systems Part 3: Control and indicating equipment FprEN 50131-5-3:2016, Alarm systems Intrusion systems Part 5-3: Requirements for in
20、terconnections equipment using radio frequency techniques CLC/TS 50131-9:2014, Alarm systems Intrusion and hold-up systems Part 9: Alarm verification Methods and principles 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 unverified alarm intr
21、uder or hold-up alarm that has not yet been sequentially, visually or audibly verified SOURCE: CLC/TS 50131-9: 2014, 3.1.14 3.2 verified alarm alarm considered genuine as a result of the use of alarm verification SOURCE: CLC/TS 50131-9: 2014, 3.1.16 3.3 lock state monitoring device apparatus which m
22、onitors the bolt position of a locking device, e.g. a bolt contact or a lock state contact as described in CLC/TS 50131-2-10 CLC/TS 50131-12:2016PD CLC/TS 50131-12:2016 3.4 blocking function logical function which prevents entry to the protected premises during the set state of the IAS. Note 1 to en
23、try: This function can be integrated in any device, e.g. lock, CIE (see Annex B). 3.5 blocking element physical device which secures the entry door and is used in conjunction with blocking function Note 1 to entry: See Annex B. 4 Methods of setting and unsetting 4.1 General The methods of setting an
24、d unsetting described may be used as complementary to alarm verification technology (CLC/TS 50131-9) or as stand-alone methods of minimizing unwanted alarms arising from errors during setting and unsetting of an IAS. In general, methods of setting and unsetting may be selected in any combination to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDCLCTS50131122016ALARMSYSTEMSINTRUSIONANDHOLDUPSYSTEMSMETHODSANDREQUIREMENTSFORSETTINGANDUNSETTINGOFINTRUDERALARMSYSTEMSIAS

链接地址:http://www.mydoc123.com/p-397605.html