BIODOSIMETRY AVAILABLE METHODS AND ROLE IN .ppt
《BIODOSIMETRY AVAILABLE METHODS AND ROLE IN .ppt》由会员分享,可在线阅读,更多相关《BIODOSIMETRY AVAILABLE METHODS AND ROLE IN .ppt(42页珍藏版)》请在麦多课文档分享上搜索。
1、BIODOSIMETRY AVAILABLE METHODS AND ROLE IN DOSE ASSESMENT AND PROGNOSIS,Module X,Module Medical X.,- 2,Accidental dosimetry,PHYSICAL DOSIMETRY,BIOLOGICAL DOSIMETRY,CLINICAL DOSIMETRY,DOSE RECONSTRUCTION, Personal Dosimeters,CYTOGENETIC DOSIMETRY Dicentrics, FISH, PCC, MNA,NAUSEA, VOMITING, BLOOD CEL
2、LS COUNTS, SKIN REACTIONS.,OTHER BIOINDICATORS,Module Medical X.,- 3,Physical dosimetry,Module Medical X.,- 4,Clinical dosimetry,Crude estimate of absorbed dose obtainable from clinical presentation,VomitingOnset: 2 h after exposure or later Onset: 1-2 h after exposure or later Onset: earlier than 1
3、 h after exposure Onset: Earlier than 30 min after exposure,MILD ARS (1-2 Gy),MODERATE ARS(2-4 Gy),SEVERE ARS (4-6 Gy),VERY SEVERE ARS (6-8 Gy),Module Medical X.,- 5,Clinical dosimetry using early changes in lymphocyte counts,Module Medical X.,- 6,Clinical dosimetry using granulocyte counts,Module M
4、edical X.,- 7,Cytogenetic dosimetry,Analysis of chromosomal aberrations in peripheral blood lymphocytes - widely used biological dosimetry method for assessing radiation dose, especially useful in persons not wearing dosimeters while exposed to radiationin cases of claims for compensation for radiat
5、ion injuries not supported by unequivocal dosimetric evidencefor validation of occupational radioprotection cases involving suspected low-dose exposures,Module Medical X.,- 8,Biophysical background to chromosome damage,*,High LET,* * * * * * * * *,Low LET,Module Medical X.,- 9,DNA damage,Module Medi
6、cal X.,- 10,Chromosomal structure,Module Medical X.,- 11,Human lymphocytes,LYMPHOCYTES,Dose assessment predominantly based on data obtained from lymphocytesEasily obtained in large quantities from peripheral bloodVast majority of peripheral lymphocytes reside in Go phase of e cell cyclePhytohaemaggl
7、utinin (PHA) converts resting lymphocytes into dividing cells allowing visualization of possible DNA lesions in methaphase chromosomes,Module Medical X.,- 12,Human karyotype,Module Medical X.,- 13,Classification of chromosomal aberrations,Inversion,Symmetrical (STABLE),Breaks,Intrachange,Asymmetrica
8、l (UNSTABLE),Centric Ring,Interchange,Translocation,Dicentric,Module Medical X.,- 14,Biological dose assessment using standard dicentric analysis,Introduced by M. Bender in 1964Isolated lymphocytes stimulated by phytohaemagglutin (PHA) into mitosisArrest of metaphase using colchicineScoring of dicen
9、tric chromosome aberrations in metaphase spreads,Module Medical X.,- 15,Dicentric chromosome aberrations in metaphase spreads,dic,dic,f,f,f,f,Module Medical X.,- 16,Dose response curves,Y = A+aD + bD2,Module Medical X.,- 17,Relationship between RBE and LET,LET (keV/m),RBE,Module Medical X.,- 18,Cali
10、bration curves,Module Medical X.,- 19,Gamma rays, X-rays acute exposure (Low LET),Gamma rays X-rays chronic exposure (Low LET), particles Fast neutrons (High LET),Dose,Dicentric yield,Y = c + aD + bD2,Y = c + aD,Y = c + aD,Dose estimation of acute vs chronic exposure,Effect,Module Medical X.,- 20,Me
11、thods for estimating radiation doses in partial body exposure: Sasaki-method,Module Medical X.,- 21,Dicentric assay,Most accurate method for dose estimation with sensitivity threshold of about 0.1 Gy for whole body low LET radiationEspecially usefulin cases where dosimeter not used, e.g. radiation a
12、ccidentto support physical dosimetry results in radiation protection and safety practiceto determine partial body exposure not detected by locally placed dosimeter,Module Medical X.,- 22,Limitations of dicentric analysis for dose estimation,Dicentrics are unstable and lymphocytes carrying aberration
13、 elimininated with time (average lifetime 150-220 days, depending on dose), hence can underestimate magnitude of doseMethod useful only within few months of irradiation,Module Medical X.,- 23,Translocation assay,In retrospective dosimetry and chronic exposure reciprocal translocations used for dose
14、assessment Translocations considered stable in cell division so yield should not fall with time Typically detected using specific whole chromosome DNA hybridization probes and FISH methodology,Module Medical X.,- 24,Stable chromosome aberration analysis with G-banding,A normal G banded male karyotyp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BIODOSIMETRYAVAILABLEMETHODSANDROLEINPPT