1、Active Insulin Infusion Control of the Blood Glucose Derivative,J G Chase, Z-H Lam, J-Y Lee and K-S HwangUniversity of Canterbury Dept of Mechanical Engineering Christchurch New ZealandICARCV 2002, Singapore,Silicon + Biology?,Many biological and/or medical processes are effectively feedback control
2、 systems or can have their function replaced by feedback systemsNew technology creating new possibilities: “BioMEMS” such as “wet sensors” and “gene chips”, are opening the path to real time physiological monitoring/sensing and actuation. Wireless technology (LAN and PAN) for communication between a
3、ctive elements and/or monitoring technology (increased information flow). Advanced embedded computers (DSPs) and real time operating systems (RTOSs) can now handle extensive calculations and operations required.Converging technologies enables the ability to monitor, control and/or replace dysfunctio
4、nal physiological behaviour(s).,Can the increased information from real-time sensing coupled with feedback control outperform the foreknowledge and intuition of an experienced diabetic?,3 Elements of Control Systems,Sensing Real-time sensing from GlucoWatch or similar technology at BW = 20 minutes o
5、r greaterComputation Modern embedded DSPs are far more than adequateActuation Insulin pumpAll are existing and near-term technologiesMust account for limitations of existing tech and determine the limits where practicality and feasibility occur together.,Diabetes,Current Treatment = Manual Monitorin
6、g + Injection = Error Prone,Diabetes is reaching epidemic proportions, treatment is dependent on unreliable individuals and has not changed significantly in 30+ years,GOALS: Automate the “5:95” (1 day every 3 weeks is “bad”) Account for variations in patient response, insulin employed, sensor bandwi
7、dth and actuator dynamics/limits.,System Model,System model is constructed in MATLAB/Simulink. Three parts: one part for each equation in model and controller. Controller: input - G and dG/dt (GlucoWatch) and output u(t) (Insulin Pump),Controllers,Relative proportional controller (RPC).,PD controlle
8、r controls slopes of incresing/decreasing blood sugar level rather than actual glucose concentration,Two controllers, one proportional based and the other derivative weighted where Kp Kd create two different approaches to controlShape control or Magnitude control,Why “Heavy Derivative” Control?,Deri
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ACTIVEINSULININFUSIONCONTROLOFTHEBLOODGLUCOSEDERIVATIVEPPT

链接地址:http://www.mydoc123.com/p-378009.html