A comparison of filter pads for the analysis of total suspended .ppt
《A comparison of filter pads for the analysis of total suspended .ppt》由会员分享,可在线阅读,更多相关《A comparison of filter pads for the analysis of total suspended .ppt(14页珍藏版)》请在麦多课文档分享上搜索。
1、A comparison of filter pads for the analysis of total suspended solids,2 June 2009,Analytical Methods and Quality Assurance Workgroup,Bill Romano MD Dept. of Natural ResourcesElgin S. Perry, Ph.D. Statistics consultant,Current procedures,DHMH and DCLS analyze TSS using a pre-rinsed Whatman GF/F 1.5
2、micron pore size filter pad, as outlined in Standard Methods CBL uses an un-rinsed Whatman GF/F 0.7 micron filter pad and reports the mean of two pads ODU also uses a Whatman GF/F 0.7 micron pad, pre-rinses, and has pre-combusted the pads since January 2002,CBL comparison of un-rinsed and rinsed GF/
3、F 0.7 pads,CBL weighed 100 pads straight from the box The pads were then rinsed with three successive 20 ml rinses of deionized water, dried overnight in a 100 degree Centigrade oven, and re-weighed It took over one hour and six liters of high quality deionized water to rinse the pads 150 pads are n
4、eeded for each main Bay cruise,CBL comparison continued,The difference in weights between un-rinsed and rinsed pads was tested using the Wilcoxon signed rank test The p-value of 0.2655 was not significant The arithmetic mean difference between un-rinsed and rinsed pads was -0.000014 grams (rinsed mi
5、nus un-rinsed) The CBL balance can only be accurately read to 0.0001 grams,Statistical mumbo jumbo,The observed instrument precision was compared to the analytical precision by calculating the variance of the differences between the un-rinsed and rinsed pads The calculated variance was divided by tw
6、o because the variance is additive The standard deviation of 0.0002 is very close to the analytical precision of 0.0001 There is no statistical or practical difference between un-rinsed and rinsed pads,Why use a smaller pore size pad,CBL started analyzing main Bay water samples in the mid-1980s The
7、designers of the main Bay monitoring program were primarily interested in the dissolved fraction of nutrients A smaller pore size pad does a better job of separating particulate and dissolved fractions of a water sample,Particulate,Dissolved,The CBL repeated measures study,Carl collected a carboy of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ACOMPARISONOFFILTERPADSFORTHEANALYSISOFTOTALSUSPENDEDPPT

链接地址:http://www.mydoc123.com/p-377813.html