ASTM E3091-17 Standard Specification for Systems to Measure Sound Levels.pdf
《ASTM E3091-17 Standard Specification for Systems to Measure Sound Levels.pdf》由会员分享,可在线阅读,更多相关《ASTM E3091-17 Standard Specification for Systems to Measure Sound Levels.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E3091 17Standard Specification forSystems to Measure Sound Levels1This standard is issued under the fixed designation E3091; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parent
2、heses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification is for measurement systems used inmaking sound pressure level measurements in buildings inaccordance with ASTM standards and guides.
3、 Systems formaking sound pressure level measurements in other environ-ments are not addressed in this specification. A future expan-sion of this specification may include these environments. Thesystems addressed include one or more microphones andassociated components to process the output of the mi
4、crophonemeasurement system conforms to a sound level meter specifi-cation it is sufficient to specify the category of precision andaccuracy required by the measurement system and that direc-tion is given in the user manual for proper use. Where thesystem is composed of components, specifications are
5、 givenfor microphone type and orientation, filters and windscreens.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It
6、is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization
7、established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C423 Test Method for SoundAbsorption and SoundAbsorp-tion
8、Coefficients by the Reverberation Room MethodC634 Terminology Relating to Building and EnvironmentalAcousticsE90 Test Method for Laboratory Measurement of AirborneSound Transmission Loss of Building Partitions andElementsE492 Test Method for Laboratory Measurement of ImpactSound Transmission Through
9、 Floor-Ceiling AssembliesUsing the Tapping MachineE1111 Test Method for Measuring the Interzone Attenuationof Open Office ComponentsE1130 Test Method for Objective Measurement of SpeechPrivacy in Open Plan Spaces Using Articulation IndexE2964 Test Method for Measurement of the NormalizedInsertion Lo
10、ss of Doors2.2 Other Standards:3,4ANSI S1.4-2014/Part 1/IEC 61672-1: 2013 Electroacoustics- Sound level meters Part 1: SpecificationsANSI S1.4-2014/Part 3/IEC 61672-3: 2013 Electroacoustics Sound level meters Part 3: Periodic testsIEC 61094-4: 1995 Electroacoustics - Measurement Micro-phones Specifi
11、cations for working standard micro-phonesANSI/ASA S1.11-2014/Part 1/IEC 61260-1: 2014 Electroa-coustics - Octave-band and fractional-octave-band filters Part 1: SpecificationsANSI S1.40-2006 Specifications and Procedures for SoundCalibratorsIEC 60942:2003 Electroacoustics Sound calibratorsANSI S1.17
12、/Part 1-2004 Microphone Windscreens Part 1:Measurements and Specifications of Insertion Loss in StillAir or Slightly Moving AirNOTE 1ANSI S1.4-2014/Part 1 and Part 3 are nationally adoptedstandards mirroring IEC 61672-1: 2013 and IEC 61672-3: 2013. Thereforeonly the IEC 61672 standards will be refer
13、enced in the rest of thisstandard. ANSI/ASA S1.11-2014/Part 1 is a nationally adopted standardmirroring IEC 61260-1:2014. Therefore only the IEC 61260-1 will bereferenced in the rest of this standard.1This specification is under the jurisdiction of ASTM Committee E33 onBuilding and Environmental Aco
14、ustics and is the direct responsibility of Subcom-mittee E33.05 on Research.Current edition approved July 1, 2017. Published July 2017. DOI: 10.1520/E3091-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of A
15、STMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.4Available from International Electrotechnical Commission (IEC), 3, rue deVa
16、remb, 1st Floor, P.O. Box 131, CH-1211, Geneva 20, Switzerland, http:/www.iec.ch.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on stan
17、dardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.13. Terminology3.1 For definitions of terms used in this specification seeTerminology C63
18、4.3.2 Definitions of Terms Specific to This Standard:3.2.1 diffuse field microphone, na microphone which pro-vides its most uniform frequency response for sound equallyincident from all angles, IEC 61094-4 Type D.3.2.2 free-field microphone, na microphone which pro-vides its most uniform frequency r
19、esponse when oriented withthe plane of its diaphragm perpendicular to the direction of thesound, IEC 61094-4 Type F.NOTE 2The complete designation of a working standard microphoneaccording to IEC 61094-4 includes “WS” and a number specifying thediameter for a half inch free-field response microphone
20、 be “WS2F”.3.2.3 frequency response (of microphones), nthe ratio ofthe electrical output of the measurement system to the soundpressure microphone dependent on the angle of incidence.3.2.4 pressure microphone, na microphone which pro-vides its most uniform frequency response when oriented withthe pl
21、ane of its diaphragm parallel to the direction of the sound,IEC 61094-4 Type P.3.2.5 windscreen, na device fitted on to a microphone toreduce the spurious sound pressures generated by turbulent airflowing around the microphone cartridge.4. Significance and Use4.1 Microphones and associated measureme
22、nt systems areused in standard test methods to measure sound pressure levels.4.1.1 Often the measurement system is obtained from themanufacturer as a complete system including subsystemscomprising one or more microphones, signal processingcircuitry, a signal analysis system and display. All of these
23、subsystems are designed to conform to a normative sound levelmeter specification. In such a measurement system:4.1.1.1 The instruction manual shall contain sufficient infor-mation for a user to obtain reproducible sound pressure levelmeasurements in various sound fields and,4.1.1.2 The performance o
24、f the system or sub systems isstraight forward to test.4.1.2 There are other measurement systems that use sophis-ticated multi-channel analyzers, filters and display systems;however these may not be supplied with a specific microphoneso they cannot conform to a normative sound level meterspecificati
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM E3091-17 Standard Specification for Systems to Measure Sound Levels E3091 17

链接地址:http://www.mydoc123.com/p-349534.html