ASTM D2729-17 Standard Specification for Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings.pdf
《ASTM D2729-17 Standard Specification for Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings.pdf》由会员分享,可在线阅读,更多相关《ASTM D2729-17 Standard Specification for Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2729 17Standard Specification forPoly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings1This standard is issued under the fixed designation D2729; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers requirements and test methodsfor materials, dimensions, workmanship, chemical resistance,and joint tightn
3、ess of poly(vinyl chloride) (PVC) sewer anddrain pipe and fittings. Perforated pipe is also covered; the jointtightness test is not applicable for perforated pipe. A form ofmarking to indicate compliance with this specification is alsoincluded.1.2 The text of this specification references notes, foo
4、tnotes,and appendixes which provide explanatory material. Thesenotes and footnotes (excluding those in tables and figures) shallnot be considered as requirements of the specification.1.3 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are fori
5、nformation only.1.4 The following precautionary caveat pertains only to thetest methods portion, Section 7, of this specification: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish ap
6、propriate safety, health, andenvironmental practices and determine the applicability ofregulatory limitations prior to use.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDeve
7、lopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD1600 Terminology forAbbreviated Terms Relating to Plas-tics
8、D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)Compounds and Chlorinated Poly(Vinyl Chloride)(CPVC) CompoundsD2122 Test Method for Determining Dimensions of Ther-moplastic Pipe and FittingsD2152 Test Method for Adequacy of Fusion of ExtrudedPoly(Vinyl Chloride) (PVC) Pipe and Molded Fitting
9、s byAcetone ImmersionD2321 Practice for Underground Installation of Thermoplas-tic Pipe for Sewers and Other Gravity-Flow ApplicationsD2412 Test Method for Determination of External LoadingCharacteristics of Plastic Pipe by Parallel-Plate LoadingD2444 Test Method for Determination of the Impact Resi
10、s-tance of Thermoplastic Pipe and Fittings by Means of aTup (Falling Weight)D2564 Specification for Solvent Cements for Poly(VinylChloride) (PVC) Plastic Piping SystemsF412 Terminology Relating to Plastic Piping Systems2.2 Federal Standard:Fed. Std. No. 123 Marking for Shipment (Civil Agencies)32.3
11、Military Standard:MIL-STD-129 Marking for Shipment and Storage33. Terminology3.1 DefinitionsDefinitions used are in accordance withTerminology F412, and abbreviations are in accordance withTerminology D1600, unless otherwise specified. The abbrevia-tion for poly(vinyl chloride) is PVC.3.1.1 perforat
12、ed pipepipe having holes cut through thewall along its length.4. Significance and Use4.1 The pipe and fittings in this specification are designedand have the physical, chemical, and other properties for sewerand drainage applications outside the building. The pipe is notintended for use as public or
13、 municipal collector sewers. Thefollowing lists the typical applications for the sewer and drainpipe:4.1.1 Building sewers and underground drainsstandard,4.1.2 Storm drainagestandard and perforated,4.1.3 House connections to septic tanksstandard,1This specification is under the jurisdiction of ASTM
14、Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.Current edition approved Sept. 1, 2017. Published November 2017. Originallyapproved in 1968. Last previous edition approved in 2011 as D2729 11. DOI:10.1520/D2729-11.2For referenced ASTM standards
15、, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from DLA Document Services, Building 4/D, 700 Robbins Ave.,Philadelphia, PA 1911
16、1-5094, http:/quicksearch.dla.mil.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized
17、principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.14.1.4 Leaching system piping for septic tank effluentsstandard and per
18、forated,4.1.5 Footing drains (foundation drains)standard andperforated,4.1.6 Industrial waste disposalstandard and perforated,and4.1.7 Land drainagestandard and perforated.5. Materials5.1 GeneralThe pipe shall be made from virgin PVCcompound with a cell classification of 12164 with a minimumtensile
19、strength of 4000 psi (28 MPa), or 12454 as defined anddescribed in Specification D1784. The fittings shall be madefrom virgin poly(vinyl chloride) compounds of cell classifica-tion PVC 12454, or PVC 13343. PVC compounds that havedifferent cell classification because one or more properties aresuperio
20、r to those of the specified compounds are also accept-able.5.2 Rework MaterialThe manufacturer shall use only hisown clean pipe or fitting rework material; the pipe and fittingsproduced shall meet all the requirements of this specification.6. Requirements6.1 Qualification and Referee Testing:6.1.1 J
21、oint TestingJoints made with pipe and fittings orbelled end pipe shall show no signs of leakage when tested inaccordance with 7.5. This test is not required for perforatedpipe.6.2 Quality Control Testing:6.2.1 WorkmanshipThe pipe and fittings shall be homo-geneous throughout and free from visible cr
22、acks, holes, foreigninclusions, or other injurious defects. The pipe shall be asuniform as commercially practical in color, opacity, density,and other physical properties.6.2.2 FlatteningThere shall be no evidence of splitting,cracking, or breaking when the pipe is tested in accordancewith 7.4.6.2.3
23、 Extrusion QualityThe pipe or fittings shall not flakeor disintegrate when tested in accordance with Test MethodD2152. In the case of fittings, slight flaking in the gate area isacceptable.6.2.4 Impact ResistanceThe impact resistance of pipeshall be determined in accordance with Test Method D2444,us
24、ing a 20-lb (10-kg) TupAand Holder B (flat plate), and shallcomply with the requirements given in Table 1 (Note 1). Forperforated pipe, samples are to be cut and tested at randomwithout regard to hole location, except that the point of impactshall not coincide with a perforation.NOTE 1This test is i
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM D2729 17 Standard Specification for Poly Vinyl Chloride PVC Sewer Pipe and Fittings

链接地址:http://www.mydoc123.com/p-294268.html