1、Designation: E2461 12 (Reapproved 2017)Standard Practice forDetermining the Thickness of Glass in Airport TrafficControl Tower Cabs1This standard is issued under the fixed designation E2461; the number immediately following the designation indicates the year oforiginal adoption or, in the case of re
2、vision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the determination of the thicknessof glass installed in airport traffic contr
3、ol towers (ATCT) toresist a specified design loading with a selected probability ofbreakage less than or equal to either 1 lite per 1000 or 4 litesper 1000 at the first occurrence of the design wind loading.1.2 The procedures apply to common outward sloping cabglass designs for which the specified l
4、oads do not exceed 10kPa (210 psf).1.3 The procedures assume control tower cab glass has anaspect ratio no greater than 2.1.4 The procedures assume control tower cab glass has anarea no less than 1.86 square metres (20 square feet).1.5 The procedures apply only to annealed monolithic,annealed lamina
5、ted, or annealed insulating glass having arectangular or trapezoidal shape.1.6 The use of the procedures assumes the following:1.6.1 Annealed monolithic and annealed laminated glassinstalled in ATCTs shall have continuous lateral support alongtwo parallel edges, along any three edges, or along all f
6、ouredges;1.6.2 Insulating glass shall have continuous lateral supportalong all four edges; and1.6.3 Supported glass edges are simply supported and freeto slip in plane.1.7 The procedures do not apply to any form of wired,patterned, etched, sandblasted, or glass types with surfacetreatments that redu
7、ce the glass strength.1.8 The procedures do not apply to any form of heat treatedglass, chemically strengthened glass, or any type of glass withsurface treatments intended to increase the glass strength.1.9 The procedures address the determination of thicknessand construction type to resist a specif
8、ied design wind load ata selected probability of breakage. The final glass thicknessand construction determined also depends upon a variety ofother factors (see 5.3).1.10 These procedures do not address blast loading on glass.1.11 The values stated in SI units are to be regarded asstandard. The valu
9、es given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.12 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this stand
10、ard to establish appro-priate safety and health practices and to determine theapplicability of regulatory limitations prior to use.1.13 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles fo
11、r theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C162 Terminology of Glass and Glass ProductsC1036 Specification for Flat GlassE631 Terminology of Buil
12、ding ConstructionsE1300 Practice for Determining Load Resistance of Glass inBuildings2.2 American Society of Civil Engineers Standard:3ASCE 7 Minimum Design Loads for Buildings and OtherStructures3. Terminology3.1 Definitions:3.1.1 For definitions of general terms related to buildingconstruction use
13、d in this practice refer to Terminology E631,1This practice is under the jurisdiction of ASTM Committee E06 on Perfor-mance of Buildings and is the direct responsibility of Subcommittee E06.52 onGlass Use in Buildings.Current edition approved April 1, 2017. Published April 2017. Originallyapproved i
14、n 2005. Last previous edition in 2012 as E2461-12. DOI: 10.1520/E2461-12R17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onth
15、e ASTM website.3Available from American Society of Civil Engineers (ASCE), 1801 AlexanderBell Dr., Reston, VA 20191, http:/www.asce.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accord
16、ance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1and for general terms related to
17、glass and glass products, referto Terminology C162.3.2 Definitions of Terms Specific to This Standard:3.2.1 annealed (AN) glass, na flat, monolithic, glass lite ofuniform thickness; it is formed by a process whereby themagnitudes of the residual stresses are nearly zero.3.2.2 aspect ratio (AR), nthe
18、 ratio of the long dimensionto the short dimension for rectangular glass or the ratio of thelong dimension to the short dimension of the rectangle thatcompletely encloses trapezoidal glass. In these procedures, ARis always equal to or greater than 1.0.NOTE 1The rectangle that completely encloses the
19、 trapezoid has twosides parallel to the horizontal edges of the trapezoid and the other twosides perpendicular to the horizontal edges of the trapezoid. All dimen-sions shall be measured from edge to edge of glass.3.2.3 equivalent rectangular area (ERA), nthe product ofthe longest horizontal glass d
20、imension and the length of theedge perpendicular to the horizontal dimension in the plane ofthe glass. All dimensions shall be measured from edge to edgeof glass.3.2.4 designated thickness for laminated glass (LG), nthedesignated thickness for LG as Table 1 specifies.3.2.5 designated thickness for m
21、onolithic glass, nthe des-ignated or nominal thickness commonly used in specifying aparticular glass product, based on the minimum thicknessespresented in Table 2 and Specification C1036.3.2.6 glass breakage, nthe fracture of any lite or ply inmonolithic, laminated, or insulating glass resulting fro
22、m stressthat an applied uniform lateral load induces.3.2.7 insulating glass (IG) unit, nconsists of any combi-nation of two glass lites, as defined herein, that enclose a sealedspace filled with air or other gas.3.2.8 laminated glass (LG), na flat-lite of uniform thick-ness that is fabricated by bon
23、ding two or more monolithic glasslites or plies of equal thickness, as defined herein, together withpolyvinyl butyral (PVB) interlayer(s).3.2.9 lateral, adjperpendicular to the glass surface.3.2.10 load, na uniformly distributed lateral pressure.3.2.10.1 design load, nthe magnitude of the 3-seconddu
24、ration load used to design glass for ATCT cabs. Equationsused herein for computing magnitudes for design loads adjustglass self weight to a magnitude consistent with a 3-secondduration.3.2.10.2 specified design load, nthe magnitude in kPa(psf), type (for example, wind or self-weight) and duration of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM E2461 12 2017 Standard Practice for Determining the Thickness of Glass in Airport Traffic Control Tower Cabs

链接地址:http://www.mydoc123.com/p-291246.html