ASTM D8130-17 Standard Test Method for Determination of Metals in Purified Terephthalic Acid (PTA) by Inductively Coupled Plasma Atomic Emission Spectrometric Method.pdf
《ASTM D8130-17 Standard Test Method for Determination of Metals in Purified Terephthalic Acid (PTA) by Inductively Coupled Plasma Atomic Emission Spectrometric Method.pdf》由会员分享,可在线阅读,更多相关《ASTM D8130-17 Standard Test Method for Determination of Metals in Purified Terephthalic Acid (PTA) by Inductively Coupled Plasma Atomic Emission Spectrometric Method.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D8130 17Standard Test Method forDetermination of Metals in Purified Terephthalic Acid (PTA)by Inductively Coupled Plasma Atomic EmissionSpectrometric Method1This standard is issued under the fixed designation D8130; the number immediately following the designation indicates the year ofo
2、riginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of metalelements i
3、n purified terephthalic acid (PTA) by inductivelycoupled plasma atomic emission spectrometry (ICP-AES).Thismethod is applicable to PTA samples containing sodium,chromium, cobalt, aluminum, titanium, potassium,magnesium, manganese, iron, nickel, molybdenum and cal-cium over 0.055 mg/kg, respectively.
4、1.2 In determining the conformance of the test results usingthis method to applicable specification, results shall be roundedoff in accordance with the rounding-off method of PracticeE29.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in th
5、isstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health and environmental practices and deter-mine the applicability of regulatory limitations pr
6、ior to use.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization Technical
7、Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD4790 Terminology of Aromatic Hydrocarbons and RelatedChemicalsD6809 Guide for Quality Control and Quality AssuranceProcedures for Aromatic Hydrocarbons and Related Ma-terialsD7111 Test
8、Method for Determination of Trace Elements inMiddle Distillate Fuels by Inductively Coupled PlasmaAtomic Emission Spectrometry (ICP-AES)E29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE177 Practice for Use of the Terms Precision and Bias inASTM Test
9、MethodsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 ISO Document:3EN ISO 8213 Chemical products for industrial useSampling techniquesSolid chemical products in theform of particles varying from powders to coarse lumps2.3 Other Document:4OSHA Reg
10、ulations, 29 CFR paragraphs 1910.1000 and1910.12003. Summary of Test Method3.1 A PTA sample is dissolved in ammonium hydroxidesolution. Calibration standards are prepared by mixing metallicstandard materials in ammonium hydroxide solution. An inter-nal standard material is added to the calibration s
11、tandards andthe sample solution to compensate for variations of testspecimen introduction efficiency. The calibration standards andthe sample solution are aspirated into the ICP-AES instrument.The concentrations of the elements in the sample solution arecalculated by comparing emission intensity rat
12、ios of the samplesolution and calibration standards to the internal standard.4. Significance and Use4.1 The presence of metals in PTA used for the productionof polyester is undesirable because they may speed up or slowdown the reaction and be impurities in the final product.1This test method is unde
13、r the jurisdiction of ASTM Committee D16 onAromatic, Industrial, Specialty and Related Chemicals and is the direct responsi-bility of Subcommittee D16.02 on Oxygenated Aromatics.Current edition approved Aug. 1, 2017. Published September 2017. DOI:10.1520/D8130-17.2For referenced ASTM standards, visi
14、t the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York,
15、 NY 10036, http:/www.ansi.org.4Available from U.S. Government Printing Office, Superintendent ofDocuments, 732 N. Capitol St., NW, Washington, DC 20401-0001, http:/www.access.gpo.gov.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis
16、 international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TB
17、T) Committee.14.2 Determination of the metals in PTA is often required.This test method is suitable for setting specifications and foruse as an internal quality control where these products areproduced or used.4.3 This test method covers the determination of sodium,chromium, cobalt, aluminum, titani
18、um, potassium,magnesium, manganese, iron, nickel, molybdenum and cal-cium.5. Apparatus5.1 Inductively-Coupled Plasma Atomic EmissionSpectrometerAny commercial sequential or simultaneousICP-AES instrument capable of measuring emission intensitiesof the elements of interest (listed in Table 1).5.2 Ana
19、lytical Balance, readable to 60.0001 g.6. Reagents and Materials6.1 Purity of ReagentsUnless otherwise indicated, it isintended that all reagents shall conform to the reagent gradespecification for analytical reagents of the American ChemicalSociety,5where such specifications are available. Other gr
20、adesmay be used, provided it is first ascertained that the reagent isof sufficiently high purity to permit its use without lesseningthe performance or accuracy of the determination. Reagentchemicals shall be used for all tests.NOTE 1Calibration and detection limits of this test method can bebiased b
21、y the purity of the reagents.6.2 Argon Gas99.99% minimum purity. (WarningArgon is under high pressure.)6.3 Nitrogen Gas99.99% minimum purity. (WarningNitrogen is under high pressure.)6.4 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean Type I reagent watercon
22、forming or exceeding Specification D1193. Freshly drawnwater should be used for preparation of all stock and workingstandards, and sample solutions.6.5 Ammonium Hydroxide25 to 28 %(wt).NOTE 2The metal impurities in ammonia hydroxide should be nomore than 10 g/kg, and the non-metallic impurities shou
23、ld be no morethan 100 mg/kg. The reagent may be purchased.6.6 Ammonium Hydroxide SolutionPipette 13 mL of am-monia hydroxide (6.5) to a 100 mL volumetric flask, fill thevolumetric flask to the mark with water.6.7 Internal Standard Stock Solution1000 mg/L. Thesingle element chosen for the internal st
24、andard should not be acomponent of the sample or calibration standard. Cadmiumand yttrium were found to perform well as an internal standardfor this test method and are recommended. The standard maybe purchased.6.8 Internal Standard Solution100 mg/L. Pipette 10 mLofInternal Standard stock solution (
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM D8130 17 Standard Test Method for Determination of Metals in Purified Terephthalic Acid PTA by Inductively Coupled Plasma Atomic Emission Spectrometric

链接地址:http://www.mydoc123.com/p-287335.html