ISO 8421-3-1989 Fire protection vocabulary part 3 fire detection and alarm《消防 词汇 第3部分 火灾的探测和报警 两种语言版》.pdf
《ISO 8421-3-1989 Fire protection vocabulary part 3 fire detection and alarm《消防 词汇 第3部分 火灾的探测和报警 两种语言版》.pdf》由会员分享,可在线阅读,更多相关《ISO 8421-3-1989 Fire protection vocabulary part 3 fire detection and alarm《消防 词汇 第3部分 火灾的探测和报警 两种语言版》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、INTERNATIONAL STANDARD NORME INTERNATIONALE IS0 8421-3 First edition Premiere Edition 1989-I l-01 Fire protection - Vocabulary - Part 3: Fire detection and alarm Protection contre Iincendie - Vocabulaire - Partie 3: Dbtection et alarme incendie Reference number Numho de reference IS0 8421-3 : 1989 (
2、E/F) Copyright International Organization for Standardization Provided by IHS under license with ISONot for ResaleNo reproduction or networking permitted without license from IHS-,-,-IS0 8421-3 : 1989 (E/F) Foreword IS0 (the International Organization for Standardization) is a worldwide federation o
3、f national standards bodies (IS0 member bodies). The work of preparing International Standards is normally carried out through IS0 technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. In
4、ternational organizations, govern- mental and non-governmental, in liaison with ISO, also take part in the work. IS0 collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. Draft International Standards adopted by the technica
5、l committees are circulated to the member bodies for approval before their acceptance as International Standards by the IS0 Council. They are approved in accordance with IS0 procedures requiring at least 75 % approval by the member bodies voting. International Standard IS0 8421-3 was prepared by Tec
6、hnical Committee ISO/TC 21, Equipment for fire protection and fire fighting. IS0 8421 consists of the following parts, under the general title Fire protection - Vocabulary : - Part 1: General terms and phenomena of fire - Part 2: Structural fire protection - Part 3: Fire detection and alarm - Part 4
7、: Fire extinction equipment - Part 5: Smoke control - Part 6: Evacuation and means of escape - Part 7: Explosion detection and suppression means - Part 8: Terms specific to fire-fighting, rescue services and handling hazardous materials 0 IS0 1989 All rights reserved. No part of this publication may
8、 be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher./Droits de reproduction r English and French alphabetical indexes are pro- vided. NOTE - In the numbering system of the terms, the
9、initial figure 3 denotes part 3 of this International Standard. La presente partie de IISO 8421 definit les termes concernant la detection et Ialarme incendie. Les termes generaux avec leurs definitions sont donnes dans IISO 8421-l. Les termes sont donnes dans Iordre alphabetique anglais en 3.1 et e
10、n 3.2, avec des index alphabetiques anglais et francais a la fin. NOTE - Dans le systeme de numerotation des termes, le premier chiffre 3 signifie la par-tie 3 de IISO 8421. Normative reference Rkfhence normative The following standard contains provisions which, through reference in this text, const
11、itute provisions of this part of IS0 8421. At the time of publication, the edition indicated was valid. All standards are subject to revision, and parties to agreements based on this part of IS0 8421 are encouraged to investigate the possibility of applying the most recent edition of the standard in
12、dicated below. Members of IEC and IS0 maintain registers of currently valid International Standards. IS0 8421-1 : 1987, Fire protection - Vocabulary - Part I: General terms and phenomena of fire. La norme suivante contient des dispositions qui, par suite de la reference qui en est faite, constituent
13、 des dispositions valables pour la presente partie de IISO 8421. Au moment de la publica- tion, ledition indiquee alarme feu : Signalisation dincen- die, initiee par une personne ou par un dispositif automatique. 1 Copyright International Organization for Standardization Provided by IHS under licens
14、e with ISONot for ResaleNo reproduction or networking permitted without license from IHS-,-,-IS0 842%3:1989 E/F) 3.1.2 alarm of fire, false: Alarm of fire (3.1.1) that is false because the fire reported does not and did not exist. This false alarm may arise by malicious, mistaken, or accidental inte
15、nt. 3.1.3 automatic fire detection and alarm system: Fire alarm system (3.1.21) comprising components for automatic- ally detecting a fire, initiating an alarm of fire and initiating other action as appropriate. NOTE - The system may also include manual fire alarm call points (3.1.14). 3.1.4 automat
16、ic fire protection equipment: Fire control or firefighting equipment, e.g. control of smoke doors, dampers, fans, or an automatic extinguishing installation. 3.1.5 automatic fire signal : Alarm of fire (3.1 .I) originated by an automatic device, given audibly and/or visibly. 3.1.6 central fire alarm
17、 station: Permanently staffed centre, usually provided by an organization which is external to the protected or monitored premises, and the staff of which, upon receipt of a fire call (3.1.22), notify the fire service. 3.1.7 control centre: Permanently staffed room within or near the premises at ris
18、k for the receipt of emergency calls and equipped with means for indicating the situation in each of the protected premises, and the communications needed for transmission of calls for assistance to emergency services. 3.1.8 control for automatic fire protection equipment: Automatic device used to a
19、ctuate automatic fire protection equipment after receiving a signal from the control and in- dicating equipment. 3.1.9 control room : Permanently staffed and fully equipped room in fire service premises in which emergency calls are received and subsequent action is taken to mobilize men, ap- pliance
20、s and equipment. 3.1.10 fault warning; (trouble signal): Automatic indica- tion giving audible and visible warning that a fault exists in a system. 3.1.11 fault warning receiving station: Room where the fault warnings (3.1.10) are received and from which the necessary corrective measures can be init
21、iated. 3.1.2 alarme injustifiee: Alarme feu (3.1.1) qui est fausse car le feu signal6 nexiste pas et na pas exist tableau de signalisation : Equipe- ment par Iintermediaire duquel le detecteur dincendie (3.2) peut etre aliment6 en Bnergie et qui a) is used to accept a detection signal and actuate a
22、fire alarm signal; a) est utilise pour recevoir le signal de detection et pour delivrer un signal dalarme feu; b) is able to pass on the fire detection signal, through fire alarm routing equipment, to the firefighting organization, or to automatic extinguishers: b) peut transmettre le signal de dete
23、ction incendie par Iintermediaire dun dispositif de transmission de Ialarme feu, par exemple au service de lutte contre Iincendie; c) is used to monitor automatically the correct functioning of the system. c) est utilise pour controler automatiquement que le systeme fonctionne et signale correctemen
24、t. 3.1.16 fire alarm device, manual: Fire alarm device, manually operated, which gives an audible and/or visible alarm of fire. 3.1.16 avertisseur manuel dincendie: Dispositif com- mande manuellement qui donne une signalisation sonore et/au visuelle dincendie. 3.1 .I7 fire alarm receiving station :
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO842131989FIREPROTECTIONVOCABULARYPART3FIREDETECTIONANDALARM 消防 词汇 部分 火灾 探测 报警 语言版 PDF

链接地址:http://www.mydoc123.com/p-1255910.html