1、 Reference number ISO 6944-1:2008(E) ISO 2008INTERNATIONAL STANDARD ISO 6944-1 First edition 2008-04-15 Fire containment Elements of building construction Part 1: Ventilation ducts Endiguement du feu lments de construction Partie 1: Conduits de ventilation ISO 6944-1:2008(E) PDF disclaimer This PDF
2、file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein t
3、he responsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF
4、-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below. COPYRIGHT PROTECTED DOCUMENT I
5、SO 2008 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in th
6、e country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2008 All rights reservedISO 6944-1:2008(E) ISO 2008 All rights reserved iii Contents Page Foreword i
7、v Introduction v 1 Scope 1 2 Normative references 2 3 Terms and definitions .2 4 Apparatus .2 5 Test conditions 10 6 Test specimen10 7 Installation of test specimen 13 8 Conditioning.15 9 Application of instrumentation.16 10 Test procedure.22 11 Performance criteria23 12 Test report 24 13 Field of d
8、irect application of test results 25 Annex A (informative) General guidance28 Bibliography 32 ISO 6944-1:2008(E) iv ISO 2008 All rights reservedForeword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of pr
9、eparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, i
10、n liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main tas
11、k of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attentio
12、n is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 6944-1 was prepared by Technical Committee ISO/TC 92, Fire safety, Subcommittee SC 2, Fire containment. T
13、his first edition of ISO 6944-1, cancels and replaces ISO 6944:1985, which has been technically revised. ISO 6944 consists of the following parts, under the general title Fire containment Elements of building construction: Part 1: Ventilation ducts A Part 2, dealing with kitchen extract ducts, is un
14、der development. ISO 6944-1:2008(E) ISO 2008 All rights reserved v Introduction The purpose of this test is to measure the ability of a representative duct or duct assembly that is part of an air-distribution system to resist the spread of fire from one fire compartment to another, with fire attack
15、from inside or outside the duct. It is applicable to vertical and horizontal ducts, with or without branches, taking into account joints and exhaust openings, as well as suspension devices and penetration points. This part of ISO 6944 is very similar to EN 1366-1, but includes an alternative arrange
16、ment for testing elbows. The test measures the length of time during which ducts of specified dimensions, suspended as they normally are in practice, satisfy defined criteria when exposed to fire from either inside or outside the duct. All ducts inside the furnace are fully restrained in all directi
17、ons. Outside the furnace, ducts exposed to fire from the outside are tested unrestrained, while ducts exposed to fire from the inside (horizontal only) are tested restrained. The test takes into account the effect of fire exposure from the outside, where a 300 Pa underpressure is maintained in the d
18、uct, as well as the effect of fire entering the ducts under conditions where forced air movement might or might not be present, by maintaining an air velocity of 3 m/s. Ducts exposed to fire from the inside are supplied with air in a manner that is representative of the “fan off” and “fan on” situat
19、ions that can arise in practice. INTERNATIONAL STANDARD ISO 6944-1:2008(E) ISO 2008 All rights reserved 1 Fire containment Elements of building construction Part 1: Ventilation ducts CAUTION The attention of all persons concerned with managing and carrying out this fire resistance test is drawn to t
20、he fact that fire testing can be hazardous and that there is the possibility that toxic and/or harmful smoke and gases can be evolved during the test. Mechanical and operational hazards can also arise during the construction of the test elements or structures, their testing and disposal of test resi
21、dues. It is strongly recommended that the duct assembly be allowed to cool completely after the fire test, before dismantling, to minimize the possibility of ignition of combustible residues. An assessment of all potential hazards and risks to health shall be made and safety precautions shall be ide
22、ntified and provided. Written safety instructions shall be issued. Appropriate training shall be given to relevant personnel. Laboratory personnel shall ensure that they follow written safety instructions at all times. 1 Scope This part of ISO 6944 specifies a method for determining the fire resista
23、nce of vertical and horizontal ventilation ducts under standardized fire conditions. The test examines the behaviour of ducts exposed to fire from the outside (duct A) and fire inside the duct (duct B). It is intended that this part of ISO 6944 be used in conjunction with ISO 834-1. This part of ISO
24、 6944 is not applicable to a) ducts whose fire resistance depends on the fire resistance performance of a ceiling, b) ducts containing fire dampers at points where they pass through fire separations, c) doors of inspection openings, unless included in the duct to be tested, d) two- or three-sided du
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO694412008FIRECONTAINMENTELEMENTSOFBUILDINGCONSTRUCTIONPART1VENTILATIONDUCTS 防火 系统 建筑结构 构件 部分 通风管道

链接地址:http://www.mydoc123.com/p-1255053.html