ISO 4150-2011 Green coffee or raw coffee - Size analysis - Manual and machine sieving《生咖啡或咖啡原料粒度分析 人工和机器筛选》.pdf
《ISO 4150-2011 Green coffee or raw coffee - Size analysis - Manual and machine sieving《生咖啡或咖啡原料粒度分析 人工和机器筛选》.pdf》由会员分享,可在线阅读,更多相关《ISO 4150-2011 Green coffee or raw coffee - Size analysis - Manual and machine sieving《生咖啡或咖啡原料粒度分析 人工和机器筛选》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、Green coffee or raw coffee Size analysis Manual and machine sieving Caf vert Analyse granulomtrique Tamisage manuel et la machine ISO 2011 Reference number ISO 4150:2011(E) Third edition 2011-11-15 ISO 4150 INTERNATIONAL STANDARDISO 4150:2011(E)COPYRIGHT PROTECTED DOCUMENT ISO 2011 All rights reserv
2、ed. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requeste
3、r. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2011 All rights reservedISO 4150:2011(E) ISO 2011 All rights reserved iii Contents Page Foreword iv 1 Scope 1 2 Normative ref
4、erences . 1 3 Terms and definitions . 1 4 Principle . 1 5 Apparatus 1 6 Sampling . 2 7 Procedure 3 7.1 Test portion . 3 7.2 Selection of sieves 3 7.3 Sieving and weighing . 3 7.4 Additional observations 3 8 Statement of results . 4 9 Precision 4 9.1 General . 4 9.2 Repeatability . 4 9.3 Reproducibil
5、ity . 4 10 Test report . 4 Annex A (normative) Characteristics of perforated metal plate test sieves with round holes 6 Annex B (normative) Characteristics of perforated metal plate test sieves with slotted apertures 8 Annex C (informative) Interlaboratory . 9 Annex D (informative) Verification of m
6、echanical equipment of sieving machines .10 Bibliography .12Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical commit
7、tees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the In
8、ternational Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International
9、 Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the
10、subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 4150 was prepared by Technical Committee ISO/TC 34, Food products, Subcommittee SC 15, Coffee. This third edition cancels and replaces the second edition (ISO 4150:1991), which has been tec
11、hnically revised. ISO 4150:2011(E)iv ISO 2011 All rights reservedINTERNATIONAL STANDARD ISO 4150:2011(E)Green coffee or raw coffee Size analysis Manual and machine sieving 1 Scope This International Standard specifies a routine method for carrying out size analysis of green coffee by manual and mach
12、ine sieving using laboratory test sieves. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amend
13、ments) applies. ISO 3, Preferred numbers Series of preferred numbers ISO 2395, Test sieves and test sieving Vocabulary ISO 2591-1, Test sieving Part 1: Methods using test sieves of woven wire cloth and perforated metal plate ISO 3310-2, Test sieves Technical requirements and testing Part 2: Test sie
14、ves of perforated metal plate ISO 3509, Coffee and coffee products Vocabulary ISO 4072, Green coffee in bags Sampling 3 Terms and definitions For the purposes of this document, the terms and definitions given in ISO 2395 (for test sieves) and ISO 3509 (for coffee) apply. 4 Principle A laboratory sam
15、ple is separated into fractions according to size by manual (or machine) sieving, and the results are expressed as percentage mass fractions. 5 Apparatus 5.1 Balance, capable of weighing to the nearest 0,1 g. 5.2 Nest of test sieves. For the dimensions and sieving medium, the test sieves shall have
16、a sieve surface area of between 550 cm 2and 1 000 cm 2 . Suitable test sieves are, for example, square sieves of size 300 mm, complying with the requirements of ISO 2591-1, except that the approximate depth of the sieve may be reduced to 25 mm. The perforated metal plate used as the sieving medium s
17、hall be made of metal of suitable strength, such as stainless steel, ordinary steel or zinc, 0,8 mm to 1 mm thick. Each plate shall be perforated in accordance with the requirements given in Annex A or Annex B. The test sieves shall be marked by means of a label attached to the sieve giving the foll
18、owing details: a) traditional numbering (see Annex A); ISO 2011 All rights reserved 1NOTE The traditional numbering is given for information purposes. It corresponds to the nominal aperture size of round apertures or to the width of slotted apertures, expressed in 64ths of an inch, closest to the me
19、tric dimension adopted. b) nominal aperture size or the dimensions of slotted apertures (see Annex B); c) in the case of round holes, the diameter of the sieve current is determined in the verification (see Annex A); d) reference to the International Standard(s) with which the sieve complies; e) mat
20、erial of the sieving medium and that of the frame; f) name of the firm (manufacturer or vendor) taking responsibility for the sieve; g) identification number. In terms of construction, the test sieve frames shall nest snugly with each other and with the lid and receiver. The frame shall be smooth an
21、d the seal of the sieve so constructed as to prevent lodging of the coffee beans being sieved. For verification, new test sieves shall be tested (for example using the methods described in ISO 3310-2) and a certificate shall be available to this effect. Periodic checking should also be performed, si
22、nce some changes in the dimensions of the apertures can occur after a period of use. 5.3 Test sieves. 5.3.1 Test sieves with round holes, 11 sieves (see Annex A). 5.3.2 Test sieves with slotted holes, 7 sieves (see Annex B). 5.4 Lid. The lid shall comply with the requirements of ISO 2591-1. 5.5 Rece
23、iver. The receiver shall comply with the requirements of ISO 2591-1. 5.6 Machine for sieving, having the following features. a) The results obtained over each sieve shall be equal to using the manual method. In Annex D, a guide is presented to carry out this verification. b) The machine shall contai
24、n a tray to allow for the assembly of a set with any number of sieves in order to carry out a complete analysis. c) It shall consist of sieves which are easy to fix. d) It shall have an adjustable timer in the 0 min to 3 min range. 6 Sampling Take a laboratory sample of 300 g, prepared in accordance
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO41502011GREENCOFFEEORRAWCOFFEESIZEANALYSISMANUALANDMACHINESIEVING 咖啡 原料 粒度 分析 人工 机器 筛选 PDF

链接地址:http://www.mydoc123.com/p-1253756.html