ISO 12980-2000 Carbonaceous materials used in the production of aluminium - Green coke and calcined coke for electrodes - Analysis using an X-ray fluorescence m.pdf
《ISO 12980-2000 Carbonaceous materials used in the production of aluminium - Green coke and calcined coke for electrodes - Analysis using an X-ray fluorescence m.pdf》由会员分享,可在线阅读,更多相关《ISO 12980-2000 Carbonaceous materials used in the production of aluminium - Green coke and calcined coke for electrodes - Analysis using an X-ray fluorescence m.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Reference number ISO 12980:2000(E) ISO 2000 INTERNATIONAL STANDARD ISO 12980 First edition 2000-04-01 Carbonaceous materials used in the production of aluminium Green coke and calcined coke for electrodes Analysis using an X-ray fluorescence method Produits carbons utiliss pour la production de lalu
2、minium Coke calcin et coke cru pour lectrodes Analyse par fluorescence aux rayons XISO 12980:2000(E) PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embe
3、dded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the responsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated.
4、 Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a prob
5、lem relating to it is found, please inform the Central Secretariat at the address given below. ISO 2000 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfi
6、lm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 734 10 79 E-mail copyrightiso.ch Web www.iso.ch Printed in Switzerland ii ISO 2000 All
7、 rights reservedISO 12980:2000(E) ISO 2000 All rights reserved iii Contents Page Foreword.iv Introduction.v 1 Scope 1 2 Normative reference 1 3 Principle1 4 Apparatus and materials.2 5 Sampling and test specimen preparation .2 6 Procedure .3 7 Expression of results 8 8 Precision.8 9 Test report 9ISO
8、 12980:2000(E) iv ISO 2000 All rights reserved Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each me
9、mber body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International E
10、lectrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 3. Draft International Standards adopted by the technical committees are circulated to the member bodies for vot
11、ing. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this International Standard may be the subject of patent rights. ISO shall not be held responsible for identifying
12、any or all such patent rights. International Standard ISO 12980 was prepared by Technical Committee ISO/TC 47, Chemistry, Subcommittee SC 7, Aluminium oxide, cryolite, aluminium fluoride, sodium fluoride, carbonaceous products for the aluminium industry.ISO 12980:2000(E) ISO 2000 All rights reserved
13、 v Introduction The determination of the elemental impurities is important for reasons of metal quality and anode consumption. This International Standard refers only to petroleum coke although the principles described are valid for pitch, anthracite, graphite or electrode materials. As the sample p
14、reparation and/or the mass fraction ranges for these other materials are quite different it is intended that specific standard methods will be published for each material.INTERNATIONAL STANDARD ISO 12980:2000(E) ISO 2000 All rights reserved 1 Carbonaceous materials used in the production of aluminiu
15、m Green coke and calcined coke for electrodes Analysis using an X-ray fluorescence method 1 Scope This International Standard specifies an X-ray fluorescence method for the determination of elemental impurities in green and calcined petroleum cokes used for the manufacture of anodes. These anodes ar
16、e used in the production of aluminium. 2 Normative reference The following normative document contains provisions which, through reference in this text, constitute provisions of this International Standard. For dated references, subsequent amendments to, or revisions of, any of these this publicatio
17、ns do not apply. However, parties to agreements based on this International Standard are encouraged to investigate the possibility of applying the most recent edition of the normative document indicated below. For undated references, the latest edition of the normative document referred to applies.
18、Members of ISO and IEC maintain registers of currently valid International Standards. ISO 6375, Carbonaceous materials for the production of aluminium Coke for electrodes Sampling. 3P r i n c i p l e A pressed tablet of pulverized coke and organic binder is irradiated by X-rays from a target thin wi
19、ndow X-ray tube. The X-ray tubes can be chromium, rhodium or scandium depending on which elements are to be determined. Irradiation of the test specimen causes ejection and rearrangement of orbital electrons resulting in the emission of secondary radiation with a characteristic wavelength for each e
20、lement. This secondary radiation is reflected, onto the detector system, by a crystal, which is set at a specific angle to the secondary radiation. Only specific radiation which obeys Braggs law reaches the detector system. n =2 d sin (1) where n is the order of the diffraction; is the X-ray wavelen
21、gth; d is the interplanar distance in the crystal; sin is the angle setting of the crystal. The intensities of the specific secondary radiation are calculated into mass fractions according to given calibration curves.ISO 12980:2000(E) 2 ISO 2000 All rights reserved 4 Apparatus and materials 4.1 X-ra
22、y fluorescence spectrometer, equipped with the following crystals: LiF 200 (lithium fluoride, reflecting plane 200), PE (pentaerythiol), PX1 (synthetic W-Si), Ge, TIAP (thallium acid phthalate) and LSM (layered synthetic microstructure). For instruments equipped with a side window X-ray tube, a scan
23、dium tube is advantageous for light elements. For instruments equipped with an end window X-ray tube, a rhodium tube offers optimum sensitivity. 4.2 Swinging-disc mill, with tungsten-carbide grinding devices. 4.3 Organic binder, suitable for pressed-tablet preparation. The binder shall not contain a
24、ny of the elements to be analysed. Suitable binders are Hoechst wachs G or stearic acid. 4.4 Tablet press, capable of providing a 20-tonne load. 4.5 Appropriate sample holders, for example aluminium dishes or brass rings with the dimensions as shown in Figure 1. 4.6 Detector gas, consisting of 90 %
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO129802000CARBONACEOUSMATERIALSUSEDINTHEPRODUCTIONOFALUMINIUMGREENCOKEANDCALCINEDCOKEFORELECTRODESANALYSISUSINGANXRAYFLUORESCENCEMPDF

链接地址:http://www.mydoc123.com/p-1250624.html