ASTM D5424-2018 Standard Test Method for Smoke Obscuration of Insulating Materials Contained in Electrical or Optical Fiber Cables When Burning in a Vertical Ca.pdf
《ASTM D5424-2018 Standard Test Method for Smoke Obscuration of Insulating Materials Contained in Electrical or Optical Fiber Cables When Burning in a Vertical Ca.pdf》由会员分享,可在线阅读,更多相关《ASTM D5424-2018 Standard Test Method for Smoke Obscuration of Insulating Materials Contained in Electrical or Optical Fiber Cables When Burning in a Vertical Ca.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5424 18Standard Test Method forSmoke Obscuration of Insulating Materials Contained inElectrical or Optical Fiber Cables When Burning in a VerticalCable Tray Configuration1This standard is issued under the fixed designation D5424; the number immediately following the designation indicat
2、es the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This is a fire-test-response standard.1.2 Th
3、is test method provides a means to measure thesmoke obscuration resulting from burning electrical insulatingmaterials contained in electrical or optical fiber cables whenthe cable specimens, excluding accessories, are subjected to aspecified flaming ignition source and burn freely under wellventilat
4、ed conditions.1.3 This test method provides two different protocols forexposing the materials, when made into cable specimens, to anignition source (approximately 20 kW), for a 20 min testduration. Use it to determine the flame propagation and smokerelease characteristics of the materials contained
5、in single andmulticonductor electrical or optical fiber cables designed foruse in cable trays.1.4 This test method does not provide information on thefire performance of electrical or optical fiber cables in fireconditions other than the ones specifically used in this testmethod, nor does it measure
6、 the contribution of the cables to adeveloping fire condition.1.5 Data describing the burning behavior from ignition tothe end of the test are obtained.1.6 The production of light obscuring smoke is measured.1.7 The burning behavior is documented visually, by pho-tographic or video recordings, or bo
7、th.1.8 The test equipment is suitable for making other,optional, measurements, including the rate of heat release ofthe burning specimen, by an oxygen consumption techniqueand weight loss.1.9 Another set of optional measurements are the concen-trations of certain toxic gas species in the combustion
8、gases.1.10 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard. (See IEEE/ASTM SI 10.)1.11 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of
9、this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.12 Fire testing is inherently hazardous. Adequate safe-guards for personnel and property shall be employed inconducting these tests.1.13 This
10、standard is used to measure and describe theresponse of materials, products, or assemblies to heat andflame under controlled conditions, but does not by itselfincorporate all factors required for fire hazard or fire riskassessment of the materials, products, or assemblies underactual fire conditions
11、.1.14 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers
12、to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D1711 Terminology Relating to Electrical InsulationD5537 Test Method for Heat Release, Flame Spread, SmokeObscuration, and Mass Loss Testing of Insulating Mate-rials Contained in Electrical or Optical Fiber Cables WhenBurning in a V
13、ertical Cable Tray ConfigurationE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE176 Terminology of Fire StandardsE800 Guide for Measurement of Gases Present or GeneratedDuring Fires1This test method is under the jurisdiction of ASTM Committee D09 onElectrical and Electronic
14、Insulating Materials and is the direct responsibility ofSubcommittee D09.17 on Fire and Thermal Properties.Current edition approved Nov. 1, 2018. Published December 2018. Originallyapproved in 1993. Last previous edition approved in 2014 as D5424 14. DOI:10.1520/D5424-18.2For referenced ASTM standar
15、ds, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM Internati
16、onal, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guid
17、es and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1E1354 Test Method for Heat and Visible Smoke ReleaseRates for Materials and Products Using an Oxygen Con-sumption CalorimeterIEEE/ASTM SI 10 Standard for Use of the InternationalSystem of Units
18、 (SI): The Modern Metric System2.2 NFPA Standards:3NFPA 70 National Electrical CodeNFPA 289 Standard Method of Fire Test for Individual FuelPackages2.3 Underwriters Laboratories Standards:4UL 1581 Reference Standard for Electrical Wires, Cables,and Flexible CordsUL1685 StandardVerticalTray Fire Prop
19、agation and SmokeRelease Test for Electrical and Optical Fiber Cables2.4 Canadian Standards Association Standards:5CSA Standard FT-4 Vertical Flame Tests: Cables in CableTrays, Section 4.11.4 in C22.2 No. 0.3, Test Methods forElectrical Wires and Cables2.5 IEEE Standards:6IEEE 1202 Standard for Flam
20、e Testing of Cables for Use inCable Tray in Industrial and Commercial Occupancies2.6 Other Standards:CA Technical Bulletin 133 Flammability Test Procedure forSeating Furniture for Use in Public Occupancies, January,19917Nordtest Method NT Fire 032 Upholstered Furniture: Burn-ing BehaviorFull Scale T
21、est8ISO 13943 Fire SafetyVocabulary93. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod and associated with fire issues, refer to TerminologyE176 and ISO 13943. In case of conflict, the definitions givenin Terminology E176 shall prevail. For definitions of termsused in this
22、 test method and associated with electrical insula-tion issues, refer to Terminology D1711.3.2 Definitions of Terms Specific to This Standard:3.2.1 sample, nan amount of the cable type and construc-tion to be tested, which is representative of the product for test.3.2.2 specimen, nthe individual len
23、gth of cable, or cablebundle, to be placed in the cable tray, which is representativeof the product to be tested.4. Summary of Test Method4.1 This fire-test-response standard determines a number offire-test-response characteristics associated with smoke obscu-ration resulting from burning the materi
24、als insulating full-scalespecimens of electrical or optical fiber cables located in avertical cable tray and ignited with a propane gas burner. Thistest method is also suitable for making other, optionalmeasurements, including rates of heat release, total amounts ofheat released, rates and concentra
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD54242018STANDARDTESTMETHODFORSMOKEOBSCURATIONOFINSULATINGMATERIALSCONTAINEDINELECTRICALOROPTICALFIBERCABLESWHENBURNINGINAVERTICALCAPDF

链接地址:http://www.mydoc123.com/p-1243648.html