1、Designation: C1741 18Standard Test Method forBleed Stability of Cementitious Post-Tensioning TendonGrout1This standard is issued under the fixed designation C1741; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method is designed to determine the bleedstability of freshly-mixed cementitious grout under staticpressure.1.2 Un
3、itsThe values stated in SI units are to be regardedas standard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro
4、-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. (WarningFreshhydraulic cementitious mixtures are caustic and may causechemical burns to skin and tissue upon prolonged exposure.2)1.4 This international standard was developed in accor-dance
5、with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standa
6、rds:3C125 Terminology Relating to Concrete and Concrete Ag-gregatesC938 Practice for Proportioning Grout Mixtures forPreplaced-Aggregate Concrete3. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod, refer to Terminology C125.3.2 Definitions of Terms Specific to This Standard
7、:3.2.1 bleed stability, nof cementitious grout, resistance tobleeding.3.2.2 bleeding, nof cementitious post-tensioning tendongrout, autogenous flow of mixing water within, or its emer-gence from, newly placed grout; caused by the settlement ofthe solid materials within the grout and the filtering ac
8、tion ofstrands and wires when subjected to static pressure andcapillary action.3.2.3 grout, nmixture of cementitious material and water,with or without aggregate and admixtures, proportioned toproduce a pourable consistency without segregation of theconstituents.3.2.4 post-tensioning, adjreferring t
9、o a method of pre-stressing in which prestressing steel is tensioned after theconcrete has gained sufficient strength.4. Significance and Use4.1 This test method is designed to evaluate the bleedstability of a freshly-mixed grout under static pressure. It canbe used in both the laboratory to qualify
10、 grout materials and inthe field as a quality control test. When used to qualify groutmaterials, replicate tests may be specified. It is intended thatthe test pressure, acceptance criteria, and number of replicatetests be set forth in the contract documents if this test methodis referenced. These va
11、lues will normally vary depending onthe vertical rise of the post-tensioning tendon.NOTE 1Appendix X1 includes a reference for an example of testpressures and bleeding limits.4.2 The procedure for this test was developed by Schokkeret al.4based on previous work by Schupack.55. Apparatus5.1 The appar
12、atus consists of a commercially availablepressure filtration funnel, stand, pressure supply with gauge,1This test method is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregates and is the direct responsibility of SubcommitteeC09.41 on Hydraulic Cement Grouts.Current editio
13、n approved Oct. 1, 2018. Published October 2018. Originallyapproved in 2011. Last previous edition approved in 2012 as C1741 12. DOI:10.1520/C1741-18.2Section on Safety Precautions, Manual of Aggregate and Concrete Testing,Annual Book of ASTM Standards, Vol 04.02.3For referenced ASTM standards, visi
14、t the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Schokker, A. J., Koester, B. D., Breen, J. E., and Kreger, M. E., “Developmentof High Performanc
15、e Grouts for Bonded Post- Tensioned Structures,” ResearchReport 1405-2, Center for Transportation Research, October 1999.5Schupack, M. “Admixture for Controlling Bleed in Cement Grout Used inPost-Tensioning,”Precast/Prestressed Concrete Institute Journal, Nov.Dec. 1974,pp. 110.*A Summary of Changes
16、section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decisio
17、n on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1pressure regulator, valve, drip wick, and bleed water collectioncontainer as shown in Fig. 1 and Fig. 2.5.1.1 Filtration Funne
18、lA 47-mm diameter stainless steelpressure filtration funnel with a nominal capacity of 200 mL asshown in Fig. 2. The filtration funnel shall have removablethreaded caps at both ends with a stem for connection of thegas supply and a 7.0 6 0.5 mm inside diameter stem 90 6 1mm long for escape of water.
19、 The base of the vessel shallcontain a 35 6 1 mm diameter stainless steel 45 m (No. 325)screen that supports a 47 mm diameter Type A/E borosilicateglass filter (1-m pore size) as shown in Fig. 2. The screen shallbe inserted with the woven side against the glass filter, and thefunnel gasket shall be
20、placed above the glass filter as shown inFig. 2. The glass filter shall cover the screen across the insidediameter of the bottom cap and be located under the gasketwhen under pressure. Secure the bottom cap before filling thefiltration funnel with grout. The funnel is placed in the standafter it is
21、filled.5.1.2 StandThe filtration funnel shall be attached to astand capable of holding the funnel in the vertical position withadequate space for the bleed water collection container. Thebottom stem of the filtration funnel shall be inserted into thebleed water collection container.5.1.3 Gas SupplyA
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC17412018STANDARDTESTMETHODFORBLEEDSTABILITYOFCEMENTITIOUSPOSTTENSIONINGTENDONGROUTPDF

链接地址:http://www.mydoc123.com/p-1243492.html