1、Designation: C1214 13C1214 19Standard Test Method forConcrete Pipe Sewerlines by Negative Air Pressure(Vacuum) Test Method1This standard is issued under the fixed designation C1214; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, t
2、he year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers procedures for testing concrete pipe sewerlines, when using the negative air pressu
3、re (vacuum) testmethod to demonstrate the integrity of the installed material and the construction procedures. This test method covers testing of4 to 36-in. diameter circular concrete pipe sewerlines utilizing gasketed joints.NOTE 1The user of this test method is advised that methods described herei
4、n may also be used as a preliminary test to enable the manufacturer orinstaller to demonstrate the condition of sewer pipe prior to delivery or backfill. Minimum test times presented in Table 1 are for pipelines. Holding timesfor testing an individual pipe may have to be increased to allow for the a
5、ccumulation of leakage when the tested pipe are incorporated into a continuouspipeline.NOTE 2The user of this test method is advised that the negative air pressure (vacuum) test criteria presented in this test method are similar to thosein general use. The test and criteria have been used widely and
6、 successfully in testing smaller diameter pipe. Larger pipe will be accepted moreconveniently by visual inspection and individual joint testing.NOTE 3Test times tabulated and the rate of air loss in this standard are based on successful testing of installed pipelines. However, since air and waterhav
7、e different physical properties, retests of some pipelines not meeting field air tests have been successful when tested with water.1.2 This test method is the inch-pound companion to Test Method C1214M; therefore, no SI equivalents are presented in thetest method.1.3 This standard does not purport t
8、o address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use. See Section 6 for speci
9、fic safety precautions.1.4 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization T
10、echnical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C822 Terminology Relating to Concrete Pipe and Related ProductsC924 Practice for Testing Concrete Pipe Sewer Lines by Low-Pressure Air Test Method (Withdrawn 2013)3C969 Practice for Infiltration and Exfiltration Ac
11、ceptance Testing of Installed Precast Concrete Pipe Sewer Lines3. Terminology3.1 DefinitionsFor definitions of terms relating to concrete pipe, see Terminology C822.4. Summary of Test Method4.1 The sewerline to be tested is plugged. Air is removed from the plugged line by a vacuum pump or vacuum res
12、ervoir. Theamount of vacuum loss is used to determine the acceptability of the sewerline.5. Significance and Use5.1 This is not a routine test. The values recorded are applicable only to the sewer being tested and at the time of testing.1 This test method is under the jurisdiction of ASTM Committee
13、C13 on Concrete Pipe and is the direct responsibility of Subcommittee C13.09 on Methods of Test.Current edition approved July 1, 2013Jan. 1, 2019. Published December 2013January 2019. Originally approved in 1992. Last previous edition approved in 20092013 asC1214 02 (2009).C1214 13. DOI: 10.1520/C12
14、14-13.10.1520/C1214-19.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard
15、and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases onl
16、y the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16. Safety Precautions6.1 WarningThe user of this test method is advised that this test
17、 may be dangerous if a line is not prepared properly andproper procedures are not followed.6.2 Access manholes or structures must be ventilated and air quality continuously monitored.6.3 No one shall be allowed in or near the manholes during testing.7. Preparation of the Sewerline7.1 Where practical
18、, clean the line prior to testing, wet the pipe surface, and eliminate debris.NOTE 4The user of this test method is advised that a wetted exterior pipe surface is desirable and will produce more consistent test results. Air maypass through the walls of dry pipe. This can be overcome by wetting the p
19、ipe. Usually, moisture absorbed from the backfill is sufficient to cope with thissituation. If the problem persists, segmental testing of the line will establish if there is a significant leak.7.2 Plug all pipe outlets including laterals. Review safety precautions in Section 6.8. Procedure8.1 Determ
20、ine the test time for the sewerline to be tested by using Table 1. Table 1 has been established using the criteriaspecified in Table 2 and the formulas contained in the Appendixes. The test time is the time required for the vacuum to drop from7 to 5 in. of mercury. (WarningMercury has been designate
21、d by EPA and many state agencies as a hazardous material that cancause central nervous system, kidney and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive tomaterials. Caution should be taken when handling mercury and mercury containing products. See the applicable produ
22、ct MaterialSafety Data Sheet (MSDS) for details and EPAs websitehttp:/www.epa.gov/mercury/faq.htmfor additional information.Users should be aware that selling mercury and/or mercury containing products into your state may be prohibited by state law.)NOTE 5To provide satisfactory test results, the va
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC12142019STANDARDTESTMETHODFORCONCRETEPIPESEWERLINESBYNEGATIVEAIRPRESSUREVACUUMTESTMETHODPDF

链接地址:http://www.mydoc123.com/p-1243456.html