ACI 352 1R-2011 Guide for Design of Slab-Column Connections in Monolithic Concrete Structures.pdf
《ACI 352 1R-2011 Guide for Design of Slab-Column Connections in Monolithic Concrete Structures.pdf》由会员分享,可在线阅读,更多相关《ACI 352 1R-2011 Guide for Design of Slab-Column Connections in Monolithic Concrete Structures.pdf(32页珍藏版)》请在麦多课文档分享上搜索。
1、ACI 352.1R-11Guide for Design of Slab-Column Connections in Monolithic Concrete StructuresReported by Joint ACI-ASCE Committee 352First PrintingMarch 2012Guide for Design of Slab-Column Connections in Monolithic Concrete StructuresCopyright by the American Concrete Institute, Farmington Hills, MI. A
2、ll rights reserved. This material may not be reproduced or copied, in whole or part, in any printed, mechanical, electronic, film, or other distribution and storage media, without the written consent of ACI.The technical committees responsible for ACI committee reports and standards strive to avoid
3、ambiguities, omissions, and errors in these documents. In spite of these efforts, the users of ACI documents occasionally find information or requirements that may be subject to more than one interpretation or may be incomplete or incorrect. Users who have suggestions for the improvement of ACI docu
4、ments are requested to contact ACI via the errata website at www.concrete.org/committees/errata.asp. Proper use of this document includes periodically checking for errata for the most up-to-date revisions.ACI committee documents are intended for the use of individuals who are competent to evaluate t
5、he significance and limitations of its content and recommendations and who will accept responsibility for the application of the mate-rial it contains. Individuals who use this publication in any way assume all risk and accept total responsibility for the application and use of this information.All
6、information in this publication is provided “as is” without warranty of any kind, either express or implied, includ-ing but not limited to, the implied warranties of merchantability, fitness for a particular purpose or non-infringement.ACI and its members disclaim liability for damages of any kind,
7、including any special, indirect, incidental, or con-sequential damages, including without limitation, lost revenues or lost profits, which may result from the use of this publication.It is the responsibility of the user of this document to establish health and safety practices appropriate to the spe
8、cific circumstances involved with its use. ACI does not make any representations with regard to health and safety issues and the use of this document. The user must determine the applicability of all regulatory limitations before applying the document and must comply with all applicable laws and reg
9、ulations, including but not limited to, United States Occupational Safety and Health Administration (OSHA) health and safety standards.Participation by governmental representatives in the work of the American Concrete Institute and in the develop-ment of Institute standards does not constitute gover
10、nmental endorsement of ACI or the standards that it develops.Order information: ACI documents are available in print, by download, on CD-ROM, through electronic subscription, or reprint and may be obtained by contacting ACI.Most ACI standards and committee reports are gathered together in the annual
11、ly revised ACI Manual of Concrete Practice (MCP).American Concrete Institute38800 Country Club DriveFarmington Hills, MI 48331U.S.A.Phone: 248-848-3700Fax: 248-848-3701www.concrete.orgISBN 978-0-87031-760-6This guide provides recommendations for determining proportions and details of monolithic rein
12、forced and post-tensioned concrete slab-column connections.Included are recommendations regarding appropriate uses of slab-column connections in structures resisting gravity and lateral forces; procedures for determination of connection load-carrying capacity; and reinforcement details to achieve ad
13、equate strength, ductility, and structural integrity. Recommendations are based on a review of the literature for ultimate and serviceability limit states. A commentary is provided to clarify the recommendations and identify reference material. Design recommendations are set in standard type. Commen
14、tary is set in italics.Keywords: connection; flat plate; flat slab; joint; lateral drift; post-tensioned; punching shear; seismic; shear reinforcement; slab-column.CONTENTSChapter 1Introduction and scope, p. 21.1Introduction1.2ScopeACI 352.1R-11Guide for Design of Slab-Column Connections in Monolith
15、ic Concrete StructuresReported by Joint ACI-ASCE Committee 352Mary Beth D. HuesteChairThomas KangSecretarySergio M. AlcocerJohn F. BonacciJames R. CagleyMarvin E. CriswellJeffrey J. DragovichCatherine E. FrenchLuis E. GarcaRussell GentryTheodor KrauthammerMichael E. KregerJames M. LaFave*Douglas D.
16、LeeDawn E. LehmanRoberto T. LeonCheng-Ming LinDonald F. MeinheitNilanjan MitraJack P. MoehleStavroula J. PantazopoulouGustavo J. Parra-MontesinosIan RobertsonM. Saiid SaiidiJorge I. SeguraBahram M. ShahroozMyoungsu ShinJohn W. WallaceJames K. WightLoring A. Wyllie Jr.Consulting MembersHossam M. Abdo
17、uFariborz BarzegarHugh L. CottonFilip C. FilippouDavid W. MitchellCharles F. ScribnerDavid Z. YankelevskyLiande Zhang*Chair of editorial subcommittee Member of editorial subcommittee1ACI Committee Reports, Guides, and Commentaries are intended for guidance in planning, designing, executing, and insp
18、ecting construction. This document is intended for the use of individuals who are competent to evaluate the significance and limitations of its content and recommendations and who will accept responsibility for the application of the material it contains. The American Concrete Institute disclaims an
19、y and all responsibility for the stated principles. The Institute shall not be liable for any loss or damage arising therefrom.Reference to this document shall not be made in contract documents. If items found in this document are desired by the Architect/Engineer to be a part of the contract docume
20、nts, they shall be restated in mandatory language for incorporation by the Architect/Engineer.ACI 352.1R-11 supersedes ACI 352.1R-89 and was adopted and published March 2012.Copyright 2011, American Concrete Institute.All rights reserved including rights of reproduction and use in any form or by any
21、 means, including the making of copies by any photo process, or by electronic or mechanical device, printed, written, or oral, or recording for sound or visual repro-duction or for use in any knowledge or retrieval system or device, unless permission in writing is obtained from the copyright proprie
22、tors.Chapter 2Notation and definitions, p. 32.1Notation2.2DefinitionsChapter 3Connection classifications, p. 43.1General3.2Connection classificationsChapter 4Design considerations, p. 84.1Connection performance4.2Types of actions on the connection4.3Determination of connection forcesChapter 5Methods
23、 of analysis for determination of connection strength, p. 95.1General principles and recommendations5.2Connections without beams5.3Connections with transverse beams5.4Effect of openings5.5Joint strengthChapter 6Reinforcement, p. 136.1Slab reinforcement for moment transfer6.2Joint recommendations6.3S
24、tructural integrity reinforcement6.4Anchorage of reinforcementChapter 7Lateral drift, p. 207.1General7.2Lateral drift capacityChapter 8Shear reinforcement, including for earthquake-resistant design, p. 228.1General8.2Types of shear reinforcement8.3Shear strength of connections with shear reinforceme
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ACI3521R2011GUIDEFORDESIGNOFSLABCOLUMNCONNECTIONSINMONOLITHICCONCRETESTRUCTURESPDF

链接地址:http://www.mydoc123.com/p-1242817.html