1、04-10 32 05 23 - 1 SECTION 32 05 23 CEMENT AND CONCRETE FOR EXTERIOR IMPROVEMENTS SPEC WRITER NOTE: Delete or add information between /-/ and any other items applicable to project. Cover any item added to the text under Applicable Publications and Products and renumber the paragraphs. See Technical
2、Notes at end of section. PART 1 - GENERAL 1.1 DESCRIPTION A. This section shall cover site work concrete constructed upon the prepared subgrade and in conformance with the lines, grades, thickness, and cross sections shown. Construction shall include the following: SPEC WRITER NOTE: Delete the items
3、 not required by the project or include any special items. See Technical Notes at end of this section. B. / Curb, / gutter, / and combination curb and gutter / wheel stop /. C. Pedestrian Pavement: / Walks / grade slabs / lawn mower strips / crossings / wheelchair curb ramps / terraces / steps /. D.
4、 Vehicular Pavement: / Service courts / driveways /. E. Equipment Pads: / Oxygen storage / transformers / propane tanks /. SPEC WRITER NOTE: If Section CONCRETE is not a portion of specification, cover items cross referenced thereto within this section, and delete all references to Section 03 30 00,
5、 CAST-IN-PLACE CONCRETE throughout this section. 1.2 RELATED WORK A. Laboratory and Field Testing Requirements: Section 01 45 29, TESTING LABORATORY SERVICES. B. Subgrade Preparation: Section 31 20 00, EARTH MOVING. C. Concrete Materials, Quality, Mixing, Design and Other Requirements: Section 03 30
6、 00, CAST-IN-PLACE-CONCRETE. D. Metal Components of Steps (Nosing and Railing): Section 05 50 00, METAL FABRICATIONS. 1.3 DESIGN REQUIREMENTS Design all elements with the latest published version of applicable codes. 1.4 WEATHER LIMITATIONS Placement of concrete shall be as specified under Article 3
7、.8, COLD WEATHER and Article 3.7, HOT WEATHER of Section 03 30 00, CAST-IN-PLACE CONCRETE. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-04-10 32 05 23 - 2 SPEC WRITER NOTE: If select subbase material is required due to unstable conditions or frost
8、 action, include the following. Also, edit all other applicable portions of this section. Spec Writer Note: if Section 03 30 00, CAST-IN-PLACE CONCRETE is not used, spec writer shall add the requirements for the Hot and Cold Weather. 1.5 SELECT SUBBASE MATERIAL JOB-MIX The Contractor shall retain an
9、d reimburse a testing laboratory to design a select subbase material mixture and submit a job-mix formula to the Resident Engineer, in writing, for approval. The formula shall include the source of materials, gradation, plasticity index, liquid limit, and laboratory compaction curves indicating maxi
10、mum density at optimum moisture. 1.6 SUBMITTALS A. In accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES, furnish the following: B. Manufacturers Certificates and Data certifying that the following materials conform to the requirements specified. 1. Expansion joint filler 2.
11、Hot poured sealing compound 3. Reinforcement 4. Curing materials C. Data and Test Reports: Select subbase material. 1. Job-mix formula. 2. Source, gradation, liquid limit, plasticity index, percentage of wear, and other tests as specified and in referenced publications. SPEC WRITER NOTE: Update appl
12、icable publications to current issue at time of project specification preparation. 1.7 APPLICABLE PUBLICATIONS A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only. Refer to the latest e
13、dition of all referenced Standards and codes. B. American Association of State Highway and Transportation Officials (AASHTO): M031MM031-07-UL Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (ASTM A615/A615M-09) M055MM055-09-UL Steel Welded Wire Reinforcement, Plain, for Concrete (AST
14、M A185) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-04-10 32 05 23 - 3 M147-65-UL . Materials for Aggregate and Soil-Aggregate Subbase, Base and Surface Courses (R 2004) M148-05-UL . Liquid Membrane-Forming Compounds for Curing Concrete (ASTM C30
15、9) M171-05-UL . Sheet Materials for Curing Concrete (ASTM C171) M182-05-UL . Burlap Cloth Made from Jute or Kenaf and Cotton Mats M213-01-UL . Preformed Expansion Joint Fillers for Concrete Paving and Structural Construction (Non-extruding and Resilient Bituminous Type) (ASTM D1751) M233-86-UL . Boi
16、led Linseed Oil Mixer for Treatment of Portland Cement Concrete T099-09-UL . Moisture-Density Relations of Soils Using a 2.5 kg. (5.5 lb) Rammer and a 305 mm (12 in.) Drop T180-09-UL . Moisture-Density Relations of Soils Using a 4.54 kg (10 lb.) Rammer and a 457 mm (18 in.) Drop C. American Society
17、for Testing and Materials (ASTM): C94/C94M-09 Ready-Mixed Concrete C143/C143M-09 Slump of Hydraulic Cement Concrete SPEC WRITER NOTE: Update materials to agree with requirements (type, grades, class, test method, tables, etc.) specified in the referenced APPLICABLE PUBLICATIONS. PART 2 - PRODUCTS 2.
18、1 GENERAL Concrete shall be Type C, air-entrained as specified in Section 03 30 00, CAST-IN-PLACE CONCRETE, with the following exceptions: TYPE MAXIMUM SLUMP* Curb use an inside edger to finish the corner at the bottom of the riser. 3. Give the risers and sidewall a final brush finish. The treads sh
19、all have a final finish with a stiff brush to provide a non-slip surface. 4. The texture of the completed steps shall present a neat and uniform appearance and shall not deviate from a straightedge test more than 5 mm (3/16 inch). 3.12 CONCRETE FINISHING FOR VEHICULAR PAVEMENT A. Accomplish longitud
20、inal floating with a longitudinal float not less than 3000 mm (10 feet) long and 150 mm (6 inches) wide, properly stiffened to prevent flexing and warping. Operate the float from foot bridges in a sawing motion parallel to the direction in which the pavement is being laid from one side of the paveme
21、nt to the other, and advancing not more than half the length of the float. B. After the longitudinal floating is completed, but while the concrete is still plastic, eliminate minor irregularities in the pavement surfaces by means of metal floats, 1500 mm (5 feet) in length, and straightedges, 3000 m
22、m (10 feet) in length. Make the final finish with the straightedges, which shall be used to float the entire pavement surface. C. Test the surface for trueness with a 3000 mm (10 foot) straightedge held in successive positions parallel and at right angles to the direction in which the pavement is be
23、ing laid and the entire area covered as necessary to detect variations. Advance the straightedge along the pavement in successive stages of not more than one half the length of the straightedge. Correct all irregularities and refinish the surface. D. The finished surface of the pavement shall not va
24、ry more than 6 mm (1/4 inch) in both longitudinal and transverse directions when tested with a 3000 mm (10 foot) straightedge. E. The thickness of the pavement shall not vary more than 6 mm (1/4 inch). F. When most of the water glaze or sheen has disappeared and before the concrete becomes nonplasti
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA3205232010CEMENTANDCONCRETEFOREXTERIORIMPROVEMENTSPDF

链接地址:http://www.mydoc123.com/p-1075017.html