1、06-01-12 08 71 13 - 1 SECTION 08 71 13 AUTOMATIC DOOR OPERATORS MODIFICATION 06-01-12 UPDATE OF STANDARDS Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-06-01-12 08 71 13 - 2 SECTION 08 71 13 AUTOMATIC DOOR OPERATORS SPEC WRITER NOTE: Delete between
2、 /-/ if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies equipment, controls and accessories for automatic operation of swing and sliding doors. 1.2 RELATED WORK A.
3、 Aluminum frames entrance work; Section 08 41 13, ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS. B. Door hardware; Section 08 71 00, DOOR HARDWARE. C. Section 28 13 00, ACCESS CONTROL. D. Glass and glazing of doors and frames; Section 08 80 00, GLAZING. E. Electric general wiring, connections and equipm
4、ent requirements; Division 26, ELECTRICAL. F. Section 28 31 00, FIRE DETECTION AND ALARM. 1.3 QUALITY ASSURANCE A. Automatic door operators, controls and other equipment shall be products of a manufacturer regularly engaged in manufacturing such equipment for a minimum of three years. B. One type of
5、 automatic door equipment shall be used throughout the building. C. Equipment installer shall have specialized experience and shall be approved by the manufacturer. 1.4 WARRANTY A. Automatic door operators shall be subject to the terms of the “Warranty of Construction“, FAR clause 52.246-21, except
6、that the Warranty period shall be two years in lieu of one year. 1.5 MAINTENANCE MANUALS A. In accordance with Section 01 00 00, GENERAL REQUIREMENTS Article titled “INSTRUCTIONS“, furnish maintenance manuals and instructions on automatic door operators. 1.6 SUBMITTALS A. Submit in accordance with S
7、ection 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-06-01-12 08 71 13 - 3 B. Manufacturers literature and data describing operators, power units, controls, door hardware and safety devices. C. Sh
8、op Drawings: 1. Showing location of controls and safety devices in relationship to each automatically operated door. 2. Showing layout, profiles, product components, including anchorage, accessories, as applicable. 3. Submit templates, wiring diagrams, fabrication details and other information to co
9、ordinate the proper installation of the automatic door operators. D. Submit in writing to Resident Engineer that items listed in Article 1.3 are in compliance. SPEC WRITER NOTE: Automatic door equipment shall be designed to accommodate the volume of traffic. Verify traffic loads with VA personnel. 1
10、.7 DESIGN CRITERIA A. As a minimum automatic door equipment shall comply with the requirements of BHMA 156.10. Except as otherwise noted on drawings, provide operators which will move the doors from the fully closed to fully opened position in / three / five / seven / seconds maximum time interval,
11、when speed adjustment is at maximum setting. B. Equipment: Conforming to UL 325. Provide key operated power disconnect wall switch for each door installation. SPEC WRITER NOTE: Ensure a dedicated circuit is provided for power supply. C. Electrical Wiring, Connections and Equipment: Provide all motor
12、, starter, controls, associated devices, and interconnecting wiring required for the installation. Equipment and wiring shall be as specified in Division 26, ELECTRICAL. 1.8 APPLICABLE PUBLICATIONS SPEC WRITER NOTE: Make material and product requirements agree with applicable requirements specified
13、in the referenced Applicable Publications. Update and specify the Publications that apply to the project. A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only. Provided by IHSNot for Res
14、aleNo reproduction or networking permitted without license from IHS-,-,-06-01-12 08 71 13 - 4 B. Builders Hardware Manufacturers Association, Inc. (BHMA): A156.10-05 . Power Operated Pedestrian Doors (BHMA 1601) C. National Fire Protection Association (NFPA): 101-09 . Life Safety Code D. Underwriter
15、s Laboratory (UL): 325-10 . Door, Drapery, Gate, Louver, and Window Operators and Systems 1.9 DELIVERY AND STORAGE A. Delivery shall be in factorys original, unopened, undamaged container with identification labels attached. SPEC WRITER NOTE: For existing buildings or additions to existing buildings
16、, door operators are to be by manufacturer of existing equipment, if possible. Coordinate with VA personnel. PART 2 - PRODUCTS 2.1 SWING DOOR OPERATORS A. General: Swing door operators shall be of institutional type, door panel size 600 mm to 1250 mm (2-0“ to 5-0“) width, weight not to exceed 300 kg
17、 (600 pounds), electric operated for overhead mounting within the header or transom. Furnish metal mounting supports, brackets and other accessories necessary for the installation of operators at the head of the door frames. The motor on automatic door operator shall be provided with an interlock so
18、 that the motor will not operate when doors are electrically locked from opening. B. Operators shall have checking mechanism providing cushioning action at last part of door travel, in both opening and closing cycle. Operators shall be capable of recycling doors instantaneously to full open position
19、 from any point in the closing cycle when control switch is activated. Operators shall, when automatic power is interrupted or shut-off, permit doors to easily open manually without damage to automatic operator system. C. Operator, enclosed in housing, shall open door by energizing motor and shall s
20、top by electrically reducing voltage and stalling motor against mechanical stop. Door shall close by means of spring energy, and close force shall be controlled by gear system and motor being used as dynamic break without power, or controlled by hydraulic closer in electro-hydraulic operators. Syste
21、m shall operate as manual door Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-06-01-12 08 71 13 - 5 control in event of power failure. Opening and closing speeds shall be adjustable: 1. Operator Housing: Housing shall be a minimum of 112 mm (4-1/2 i
22、nches) wide by 140 mm (5.5 inches) high aluminum extrusions with enclosed end caps for application to 100 mm (4 inches) and larger frame systems. All structural sections shall have a minimum thickness of 3.2 mm (0.125 inch) and be fabricated of a minimum of 6063-T5 aluminum alloy. 2. Power Operator:
23、 Completely assembled and sealed unit which shall include gear drive transmission, mechanical spring and bearings, all located in aluminum case and filled with special lubricant for extreme temperature conditions. Complete unit shall be rubber mounted with provisions for easy maintenance and replace
24、ment, without removing door from pivots or frame. 3. Connecting hardware shall have drive arm attached to door with a pin linkage rotating in a self-lubricating bearing. Door shall not pivot on shaft of operator. 4. Electrical Control: Operator shall have a self contained electrical control unit, in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA0871132012AUTOMATICDOOROPERATORSPDF