1、01-11 08 71 13.11 - 1 SECTION 08 71 13.11 LOW ENERGY POWER ASSIST DOOR OPERATORS SPEC WRITER NOTES: 1. Use this section only for NCA projects 2. Delete between / -/ if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. PART 1
2、 - GENERAL 1.1 DESCRIPTION This section specifies low energy power assisted automatic operation of swing doors. The door operator system shall be complete including operator, controls, door arm and operator enclosure (header and cover). 1.2 RELATED WORK A. Sealants; Section 07 92 00, JOINT SEALANTS.
3、 B. Steel doors; Section 08 11 13, HOLLOW METAL DOORS AND FRAMES. C. Wood doors; Section 08 14 00, INTERIOR WOOD DOORS. D. Aluminum frames entrance work; Section 08 41 13, ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS. E. Door hardware; Section 08 71 00, DOOR HARDWARE. F. Glass and glazing of doors and
4、frames; Section 08 80 00, GLAZING. G. Finish Color, Section 09 06 00, SCHEDULE FOR FINISHES. H. Smoke detectors for control of fire/smoke doors to be wired per Section 28 31 00, FIRE DETECTION AND ALARM. I. Electric general wiring, connections and equipment requirements; Division 26, ELECTRICAL. 1.3
5、 MANUFACTURERS QUALIFICATIONS A. Power assisted door operators, controls and other equipment shall be products of a manufacturer regularly engaged in manufacturing such equipment for a minimum of three years. B. One manufacturer of automatic door equipment shall be used throughout the building / pro
6、ject /. 1.4 WARRANTY Power assisted door operators, controls and other related equipment shall be subject to the terms of the “Warranty of Construction“, FAR clause 52.246-21, except that the warranty period shall be two years in lieu of one year. Provided by IHSNot for ResaleNo reproduction or netw
7、orking permitted without license from IHS-,-,-01-11 08 71 13.11 - 2 1.5 MAINTENANCE MANUALS In accordance with Section 01 00 00, GENERAL REQUIREMENTS Article titled “INSTRUCTIONS,“ furnish / two / three / copies of maintenance manuals and instructions on automatic door operators. 1.6 SUBMITTALS A. S
8、ubmit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Manufacturers literature and data describing operators, power units, controls, door hardware and safety devices. C. Shop Drawings: Showing location of controls and safety devices in relationship to each automatic
9、ally operated door. This includes templates, wiring diagrams, fabrication details, anchorage and other information to providers of related work to coordinate the proper installation of the door operators. 1.7 DESIGN CRITERIA A. Power assisted automatic door equipment shall accommodate normal traffic
10、 as well as the weight of the doors. B. Equipment: UL approved and comply with applicable codes. Motors shall be rated minimum one-quarter horsepower and shall be single phase and 115 volts. C. Electrical Wiring; Provide wiring so that only a single power supply is required. Equipment and wiring sha
11、ll be as specified in Division 26, ELECTRICAL. 1.8 APPLICABLE PUBLICATIONS SPEC WRITER NOTE: Make material and product requirements agree with applicable requirements specified in the referenced Applicable Publications. Update and specify only that which applies to the project. A. The publications l
12、isted below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only. B. American National Standards Institute (ANSI): ICC/ANSI A117.1-03Guideline for Accessible and Usable Buildings and Facilities-Providing Accessibility a
13、nd Usability for Physically Handicapped People Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-01-11 08 71 13.11 - 3 B. Builders Hardware Manufacturers Association, Inc. (BHMA): 156.19-07.Power Assist and Low Energy Power Operated Doors PART 2 - PROD
14、UCTS SPEC WRITERS NOTE: Low energy automatic door operators are not recommended for high traffic doors. Coordinate door locations and operations with NCA staff. Doors shall have hardware for manual operation in event of power failure. Door hardware and door operators shall be by manufacturer of exis
15、ting products where possible. Discuss with the NCA staff for emergency power requirement. 2.1 OPERATORS A. Automatic door operators shall be for commercial doors and shall be electromechanical and surface mounted above the door to the header or transom bar. The opening force shall be generated by a
16、permanent magnet DC motor driving a combination spiral bevel/spur gear reducer and transmitted to the door through an arm linkage. Opening speed shall be adjustable and feature dual backcheck control allowing adjustment of backcheck speed and position. Closing shall be by spring force generated by a
17、 metal compression spring. The spring shall reduce manual opening force to not more than 67 N (15 lbf). The minimum diameter of spring wire shall be .007mm (172 in.). Under the specified design load of the door, the spring shall be capable of performing 2,000,000 cycles before fracture. Adjustable c
18、losing speed and fixed latch speed shall control the door in the closing cycle. The doors shall be operated manually at any time without damage to the operator or components. B. All operators shall have checking mechanism providing cushioning action at last part of door travel, in both opening and c
19、losing cycle. Operators shall recycle doors instantaneously to full open position from any point in closing cycle when control switch is reactivated. C. Operator shall be swinging type enclosed in housing. Operator shall open door by energizing motor and shall stop by electrically reducing voltage a
20、nd stalling motor against mechanical stop. Door shall close by means of spring energy, and close force shall be controlled by gear system and motor being used as dynamic break without power. System shall operate as manual door control in event of power failure. Opening and closing speeds shall be ad
21、justable: Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-01-11 08 71 13.11 - 4 1. Swing Operator Housing: Housing shall be 140 mm (5-1/2 inches) wide by 150 mm (6 inches) high aluminum extrusions with enclosed end caps for application to 100 mm (4 i
22、nch) and larger frame systems. All structural sections shall have a minimum thickness of 3.7 mm (0.146 inch) and be fabricated of 6063-T5 aluminum alloy. 2. Swing Power Operator: Completely assembled and sealed unit which shall include helical gear drive transmission, mechanical spring and bearings,
23、 all located in cast aluminum case and filled with special lubricant for extreme temperature conditions. A “DC“ shunt-wound permanent magnet motor with sealed ball bearings shall be attached to transmission system. Complete unit shall be rubber mounted with provisions for easy maintenance and replac
24、ement, without removing door from pivots or frame. 3. Connecting hardware for swing overhead concealed type power operator shall have drive arm attached to door with a pin linkage rotating in a self-lubricating bearing and adjustable slide block, traveling in an interconnected track and top pivot as
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA087113112011LOWENERGYPOWERASSISTDOOROPERATORSPDF

链接地址:http://www.mydoc123.com/p-1074763.html