1、10-10 07 60 00 - 1 SECTION 07 60 00 FLASHING AND SHEET METAL SPEC WRITER NOTES: 1. Delete or edit text in if not applicable to project. Also delete any other paragraph not applicable in the section and renumber the paragraphs. 2. This section requires close coordination with roofing and masonry sect
2、ions for flashing installed by other trades and for flashings integral with manufactured metal roofing/wall systems where matching finish is required of the same material. 3. Coordinate with drawing terminology for correct and uniform nomenclature. 4. Follow the recommendations of the National Roofi
3、ng Contractors Association “Roofing and Waterproofing Manual“ for design criteria. 5. Modify this section to address reroofing of existing roofing system. Coordinate with Section 07 01 50.19 PREPARATION FOR REROOFING for reroofing of existing facilities. PART 1 - GENERAL 1.1 DESCRIPTION Formed sheet
4、 metal work for wall and roof flashing, copings, roof edge metal, fasciae, drainage specialties, and formed expansion joint covers are specified in this section. 1.2 RELATED WORK SPEC WRITER NOTE: Edit Related Work to reflect other sections relating directly to this section or referenced in this sec
5、tion. A. Manufactured flashing, copings, roof edge metal, and fasciae: Section 07 71 00 ROOF SPECIALTIES. B. Membrane base flashings and stripping: /Section 07 51 00, BUILT-UP BITUMINOUS ROOFING/ /Section 07 52 16 MODIFIED BITUMINOUS MEMBRANE ROOFING/. C. Flashing components of factory finished roof
6、ing and wall systems: Division 07 roofing and wall system sections. D. Joint Sealants: Section 07 92 00, JOINT SEALANTS. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-10-10 07 60 00 - 2 E. Color of factory coated exterior architectural metal and an
7、odized aluminum items: Section 09 06 00, SCHEDULE FOR FINISHES. F. Integral flashing components of manufactured roof specialties and accessories or equipment: /Section 07 71 00, ROOF SPECIALTIES/ /Section 07 72 00, ROOF ACCESSORIES/, Division 22, PLUMBING sections and Division 23 HVAC sections. G. P
8、aint materials and application: Section 09 91 00, PAINTING. H. Flashing and sheet metal in connection with prefabricated metal buildings: Section 13 34 19, METAL BUILDING SYSTEMS. I. Flashing of Roof Drains: Section 22 14 00, FACILITY STORM DRAINAGE . 1.3 APPLICABLE PUBLICATIONS SPEC WRITER NOTES: 1
9、. Update applicable publications to current issue at time of project specification preparation. 2. Update material requirements to agree with applicable requirements (types, grades, classes,) specified in the referenced Applicable Publications. A. Publications listed below form a part of this specif
10、ication to the extent referenced. Publications are referenced in the text by the basic designation only. Editions of applicable publications current on date of issue of bidding documents apply unless otherwise indicated. B. Aluminum Association (AA): AA-C22A41.Aluminum Chemically etched medium matte
11、, with clear anodic coating, Class I Architectural, 0.7-mil thick AA-C22A42.Chemically etched medium matte, with integrally colored anodic coating, Class I Architectural, 0.7 mils thick AA-C22A44.Chemically etched medium matte with electrolytically deposited metallic compound, integrally colored coa
12、ting Class I Architectural, 0.7-mil thick finish C. American National Standards Institute/Single-Ply Roofing Institute (ANSI/SPRI): ANSI/SPRI ES-1-03.Wind Design Standard for Edge Systems Used with Low Slope Roofing Systems D. American Architectural Manufacturers Association (AAMA): Provided by IHSN
13、ot for ResaleNo reproduction or networking permitted without license from IHS-,-,-10-10 07 60 00 - 3 AAMA 620Voluntary Specification for High Performance Organic Coatings on Coil Coated Architectural Aluminum AAMA 621Voluntary Specification for High Performance Organic Coatings on Coil Coated Archit
14、ectural Hot Dipped Galvanized (HDG) and Zinc-Aluminum Coated Steel Substrates E. ASTM International (ASTM): A167-99(R2009)Stainless and Heat-Resisting Chromium-Nickel Steel Plate, Sheet, and Strip A653/A653M-09.Steel Sheet Zinc-Coated (Galvanized) or Zinc Alloy Coated (Galvanized) by the Hot- Dip Pr
15、ocess B32-08Solder Metal B209-07.Aluminum and Aluminum-Alloy Sheet and Plate B370-09.Copper Sheet and Strip for Building Construction D173-03.Bitumen-Saturated Cotton Fabrics Used in Roofing and Waterproofing D412-06.Vulcanized Rubber and Thermoplastic Elastomers-Tension D1187-97(R2002).Asphalt Base
16、 Emulsions for Use as Protective Coatings for Metal D1784-08Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds D3656-07Insect Screening and Louver Cloth Woven from Vinyl-Coated Glass Yarns D4586-07Asphalt Roof Cement, Asbestos Free F. Sheet Metal and A
17、ir Conditioning Contractors National Association (SMACNA): Architectural Sheet Metal Manual. G. National Association of Architectural Metal Manufacturers (NAAMM): AMP 500-06Metal Finishes Manual H. Federal Specification (Fed. Spec): A-A-1925A.Shield, Expansion; (Nail Anchors) UU-B-790A.Building Pape
18、r, Vegetable Fiber Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-10-10 07 60 00 - 4 I. International Code Commission (ICC): International Building Code, Current Edition 1.4 PERFORMANCE REQUIREMENTS SPEC WRITER NOTE: Select applicable subparagraph b
19、elow based upon FM Approvals 1-28, Table 4. Coordinate with uplift requirements of Division 07 roofing section. A. Wind Uplift Forces: Resist the following forces per FM Approvals 1-49: 1. Wind Zone 1: 0.48 to 0.96 kPa (10 to 20 lbf/sq. ft.): 1.92-kPa (40-lbf/sq. ft.) perimeter uplift force, 2.87-kP
20、a (60-lbf/sq. ft.) corner uplift force, and 0.96-kPa (20-lbf/sq. ft.) outward force. 2. Wind Zone 1: 1.00 to 1.44 kPa (21 to 30 lbf/sq. ft.): 2.87-kPa (60-lbf/sq. ft.) perimeter uplift force, 4.31-kPa (90-lbf/sq. ft.) corner uplift force, and 1.44-kPa (30-lbf/sq. ft.) outward force. 3. Wind Zone 2:
21、1.48 to 2.15 kPa (31 to 45 lbf/sq. ft.): 4.31-kPa (90-lbf/sq. ft.) perimeter uplift force, 5.74-kPa (120-lbf/sq. ft.) corner uplift force, and 2.15-kPa (45-lbf/sq. ft.) outward force. 4. Wind Zone 3: 2.20 to 4.98 kPa (46 to 104 lbf/sq. ft.): 9.96-kPa (208-lbf/sq. ft.) perimeter uplift force, 14.94-k
22、Pa (312-lbf/sq. ft.) corner uplift force, and 4.98-kPa (104-lbf/sq. ft.) outward force. SPEC WRITER NOTE: Standard below applies to shop-fabricated sheet metal copings and roof edge metal items tested under cited standard; it is a requirement of the current International Building Code. NRCA member f
23、irms are able to meet below utilizing NRCA-approved and tested details. B. Wind Design Standard: Fabricate and install /copings/ /roof-edge flashings/ tested per ANSI/SPRI ES-1 to resist design pressure /insert design pressure/ /indicated on Drawings/. 1.5 SUBMITTALS A. Submit in accordance with Sec
24、tion 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. SPEC WRITER NOTE: Add to shop drawing list special items not specified in this section that are added to this section. B. Shop Drawings: For all specified items, including: Provided by IHSNot for ResaleNo reproduction or networking permitted w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA0760002010FLASHINGANDSHEETMETALPDF