《UL SUBJECT 6141-2009 OUTLINE OF INVESTIGATION FOR WIND TURBINE CONVERTERS AND INTERCONNECTION SYSTEMS EQUIPMENT (Issue 1)《风力发电机变流器和互连系统设备的调查大纲 (议题1)》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 6141-2009 OUTLINE OF INVESTIGATION FOR WIND TURBINE CONVERTERS AND INTERCONNECTION SYSTEMS EQUIPMENT (Issue 1)《风力发电机变流器和互连系统设备的调查大纲 (议题1)》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMay 1, 20091SUBJECT 6141OUTLINE OF INVESTIGATIONFORWIND TURBINE CONVERTERS AND INTERCONNECTION SYSTEMSEQUIPMENTISSUE No. 1May 1, 2009Summary of TopicsThis is the first issue of the Outline of Inv
2、estigation for Wind TurbineConverters and Interconnection Systems Equipment.The UL Foreword is no longer located within the UL Standard. For informationconcerning the use and application of the requirements contained in thisStandard, the current version of the UL Foreword is located onULStandardsInf
3、oNet at: http:/ 2009 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMAY 1, 2009SUBJECT 61412No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FR
4、OM ULCONTENTSINTRODUCTION1 Scope .42 Components 43 Units of Measurement .54 Undated References 5CONSTRUCTION5 General 56 Liquid Cooling Systems 5PERFORMANCE7 General 58 Stand Alone Operation 69 Utility Grid Interaction 69.1 General .69.2 Utility grid interaction performance 610 Abnormal Conditions .
5、7MARKINGS, RATINGS AND INSTRUCTIONS11 Markings and Ratings 712 Instructions 8APPENDIX AStandards for ComponentsA1MAY 1, 2009 SUBJECT 6141 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover Wind Tur
6、bine Converter (WTC) products and assemblies. Some of thefeatures and functions of these products include but are not limited to, generation of real and reactivepower in parallel with the electric power system, EPS (electric utility grid), supplying power in a standaloneoperational mode, multiple mo
7、de operation, and bidirectional power flow operation with the EPS.1.2 These requirements address WTC products and assemblies intended for installation in accordancewith their ratings, installation instructions, the National Electrical Code, ANSI/NFPA 70, and applicableutility and model building code
8、s.1.3 These requirements also address wind turbine utility interconnection systems equipment (WTUISE)that performs utility interconnection protection functions for paralleling wind turbines with the EPS.2 Components2.1 Except as indicated in 2.2, a component of a product covered by this outline shal
9、l comply with therequirements for that component. See Appendix A for a list of standards covering components generallyused in the products covered by this outline.2.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the ap
10、plication of the component in theproduct covered by this outline, orb) Is superseded by a requirement in this outline.2.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.2.4 Specific components are incomplete in construction features or restricte
11、d in performance capabilities.Such components are intended for use only under limited conditions, such as certain temperatures notexceeding specified limits, and shall be used only under those specific conditions.MAY 1, 2009SUBJECT 61414UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION
12、 ORDISTRIBUTION WITHOUT PERMISSION FROM UL3 Units of Measurement3.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.4 Undated References4.1 Any undated reference to a code or standard appearing in the requirements of this Outline
13、 ofInvestigation shall be interpreted as referring to the latest edition of that code or standard.CONSTRUCTION5 General5.1 The constructions of WTCs and assemblies shall comply with applicable portions of the Standard forInverters, Converters, Controllers and Interconnection System Equipment for Use
14、 With Distributed EnergyResources, UL 1741, or the Standard for Power Conversion Equipment, UL 508C.6 Liquid Cooling Systems6.1 WTCs with liquid cooling systems shall comply with the applicable requirements from the Standardfor Power Conversion Equipment, UL 508C.PERFORMANCE7 General7.1 WTCs and ass
15、emblies shall be evaluated for their rated electrical and environmental operatingconditions.7.2 WTCs and assemblies shall comply with the normal and abnormal testing criteria specified in thestandards referenced in Sections710.7.3 Electronic controls and power electronics circuits shall comply with
16、the Standard for Inverters,Converters, Controllers and Interconnection System Equipment for Use With Distributed EnergyResources, UL 1741.MAY 1, 2009 SUBJECT 6141 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL8 Stand Alone Operation8.1 WTCs
17、 intended for stand-alone operation shall comply with the applicable stand-alone performancerequirements in the Standard for Inverters, Converters, Controllers and Interconnection SystemEquipment for Use With Distributed Energy Resources, UL 1741.9 Utility Grid Interaction9.1 General9.1.1 WTCs rated
18、 for connection and operation with an EPS shall be evaluated for the purpose asspecified by this section.9.2 Utility grid interaction performance9.2.1 For utility interactive WTCs or WTUISE that perform Low Voltage Ride Through (LVRT) electric gridsupport, the WTGS shall be evaluated in accordance w
19、ith Wind turbines Part 21: Measurement andassessment of power quality characteristics of grid connected wind turbines, IEC 61400-21, to confirm themanufacturers declared electrical and power quality ratings.Exception: A WTC need not be evaluated as required in 9.2.1 provided it is marked in accordan
20、ce with11.3 and 12.2.9.2.2 Utility interactive WTCs or WTUISE intended for connection at electric utility distribution levels shallcomply with the applicable requirements of the Standard for Inverters, Converters, Controllers andInterconnection System Equipment for Use With Distributed Energy Resour
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT61412009OUTLINEOFINVESTIGATIONFORWINDTURBINECONVERTERSANDINTERCONNECTIONSYSTEMSEQUIPMENTISSUE1

链接地址:http://www.mydoc123.com/p-1069461.html