1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMay 1, 20091SUBJECT 6140OUTLINE OF INVESTIGATIONFORWIND TURBINE GENERATING SYSTEMSIssue No. 1May 1, 2009Summary of TopicsThis is the first issue of the Subject 6140 Outline of Investigation for W
2、indTurbine Generating Systems.The UL Foreword is no longer located within the UL Standard. For informationconcerning the use and application of the requirements contained in thisStandard, the current version of the UL Foreword is located onULStandardsInfoNet at: http:/ 2009 UNDERWRITERS LABORATORIES
3、 INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMAY 1, 2009SUBJECT 61402No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 General 4
4、2.1 Components .42.2 Units of Measurement .52.3 Undated References 53 Special Components and Subassemblies of WTGS .53.1 Wiring .53.2 Cable drip loop 63.3 Bus bars 63.4 Switchgear 83.5 Transformers .83.6 Hub .93.7 Converter/Inverter 93.8 Lightning protection systems .93.9 Slip rings 93.10 Gearboxes
5、103.11 Hoists and winches .103.12 Fire alarms 113.13 Emergency stop 11CONSTRUCTIONWTGS AND SUBASSEMBLY4 General .125 Disconnection Device 126 Spacings 137 Energy Storage Units .147.1 General .147.2 Battery mounting 148 Working Space 159 Safety Related Controls System (SRCS) 169.1 General 169.2 Prote
6、ction functions 169.3 Abnormal conditions for safety related controls system .17APPENDIX AStandards for ComponentsA1MAY 1, 2009 SUBJECT 6140 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 This Outline of Investigation
7、covers Wind Turbine Generating Systems (WTGS) and electricalsubassemblies. These units are intended for use in stand-alone (not grid-connected) or utility interactiveapplications. Utility-interactive WTGS are operated in parallel with an electric power system (EPS) tosupply power to common loads.1.2
8、 The WTGS power, control and protection systems are evaluated only to the extent that they functionwithin the manufacturers specified limits and response times. These control and protection functions areevaluated with respect to risk of electric shock and fire. It is intended that the electrical sub
9、assemblies thataddress power transfer control and protection functions evaluated per this document are to be coordinatedwith the mechanical and structural evaluation of the WTGS in accordance with the IEC 61400 seriesdocuments or Germanischer Lloyd WindEnergie GMBH: Guideline for the Certification o
10、f Wind Turbinesdocuments.1.3 This Outline of Investigation does not cover:a) WTGS intended for off-shore installation.b) Mechanical or structural integrity of the WTGS or subassemblies.c) Coordination of electrical and mechanical systems to maintain the WTGS within its safemechanical and structural
11、limits.d) Mechanical loading of ladders, scaffolding, personnel tie offs, or other personnel loadbearing functional parts.1.4 The products, systems, and subassemblies covered by these requirements are intended to beinstalled in accordance with the National Electrical Code, ANSI/NFPA 70.2 General2.1
12、Components2.1.1 Except as indicated in 2.1.2, a component of a product covered by this Outline shall comply withthe requirements for that component. See Appendix A for a list of standards covering components usedin the products covered by this Outline. See also Section 3, Special Components and Suba
13、ssemblies ofWTGS.2.1.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this Outline, orb) Is superseded by a requirement in this Outline.MAY 1, 2009SUBJECT 61404UL
14、 COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL2.1.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.2.1.4 Specific components are incomplete in construction features or restricted in perfor
15、mancecapabilities. Such components are intended for use only under limited conditions, such as certaintemperatures not exceeding specified limits, and shall be used only under those specific conditions.2.1.5 Components and subassemblies of the overall WTGS shall be evaluated and found suitable forop
16、eration over the normal range of electrical and environmental conditions as specified by the WTGSmanufacturer.2.2 Units of Measurement2.2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.2.3 Undated References2.3.1 Any undated r
17、eference to a code or standard appearing in the requirements of this Outline ofInvestigation shall be interpreted as referring to the latest edition of that code or standard.3 Special Components and Subassemblies of WTGS3.1 Wiring3.1.1 Internal wiring shall comply with the Standard for Industrial Co
18、ntrol Equipment, UL 508, in additionto the requirements in this section.3.1.2 Wiring that is subject to movement, flexing, or twisting during operation of the wind turbine shall beinvestigated for suitability in the conditions of use and rated life or cycle time.3.1.3 All wiring within a WTGS that i
19、s large enough for service personnel to enter the structure shall berated for tray cable usage. The following meet the intent of the requirement:a) Multiconductor cable complying with the Outline of Investigation for Flexible Motor SupplyCable and Wind Turbine Tray Cable, Subject 2277, and marked fo
20、r Wind Turbine usage.b) Power-limited circuit cabling complying with the Standard for Power-Limited Circuit Cables,UL 13, suitable for Tray Cable usage (Types CMG, CM, CL2, CL3, PLTC, CMR, CL2R, CL3R,CMP, CL2P, CL3P).c) Optical fiber circuits complying with the Standard for Optical Fiber Cable, UL 1
21、651.d) Power cabling complying with the Standard for Thermoplastic-Insulated Wires and Cables,UL 83, or the Standard for Thermoset-Insulated Wires and Cables, UL 44, and additionallymarked for Cable Tray usage (“CT”, “For Cable Tray Use”, “For CT Use”, or “For Use in CableTrays”) or marked FT4.Excep
22、tion: Wiring within a component need only meet the requirements for the component.Note: For Canada, an FT4 rating is required per the Canadian Electrical Code.MAY 1, 2009 SUBJECT 6140 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3.1.4 Wiri
23、ng within a rotating hub shall be additionally protected from mechanical damage. Suchprotection may be provided by enclosures or conduit complying with the Standard for Metallic OutletBoxes, UL 514A, and/or the Standard for Conduit, Tubing, and Cable Fittings, UL 514B, mechanicalshielding, or the eq
24、uivalent.3.1.5 Wiring subjected to exposure to water or oil during normal or abnormal conditions such as a gasketor seal leak shall be suitably rated for the condition.3.1.6 Wiring subjected to UV exposure shall be rated for exposure to sunlight.3.2 Cable drip loop3.2.1 If operation of the wind turb
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT61402009OUTLINEOFINVESTIGATIONFORWINDTURBINEGENERATINGSYSTEMSISSUE1 风力 发电 系统 调查 大纲 议题 PDF

链接地址:http://www.mydoc123.com/p-1069460.html