1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSeptember 14, 20101SUBJECT 2733OUTLINE OF INVESTIGATIONFORSURFACE VEHICLE ON-BOARD CABLEIssue Number: 2September 14, 2010Summary of TopicsThis second issue of the Outline of Investigation for Sur
2、faceVehicle On-Board Cable includes the following:Required cold rating of 30C (rather than 25C) with the optionof 40C;Change in description of the ethanol blend to align withrequirements for Equipment Compatibility with Fuels and Biofuels;Limitation on materials allowed to have an ethanol exposure r
3、atingbased on requirements for Equipment Compatibility with Fuelsand Biofuels;Clarification of the compliance criteria for the weatherometer test;andCorrection of the compliance criteria in the abrasion test.COPYRIGHT 2010 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURT
4、HER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSEPTEMBER 14, 2010SUBJECT 27332No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Units of Measurement .43 Components 44 Undated Referen
5、ces 5CONSTRUCTION5 Materials and Workmanship 56 General 56.1 Assembly 56.2 Conductors 56.3 Insulation 66.4 Shield .66.5 Jacket .7PERFORMANCE7 General 78 Manufacturing and Production Test 15MARKINGS9 General .1510 Tag, Reel, or Carton Markings .16SEPTEMBER 14, 2010 SUBJECT 2733 3UL COPYRIGHTED MATERI
6、AL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 This outline covers the requirements for single conductor cables for use in on-board surface vehicles.The cable is rated:a) 60, 75, 90, or 105C;b) minus 30C;c) oil resistant;d) water resistant;
7、 ande) either 300 or 600 V, ac or dc.2 Units of Measurement2.1 In addition to being stated in the inch/pound units that are customary in the USA, each of therequirements in this outline is also stated in units that make the requirement conveniently usable incountries employing the metric system (pra
8、ctical SI). Equivalent although not necessarily exactlyidentical results are to be expected from applying a requirement in USA or metric terms. Equipmentcalibrated in metric units is to be used when a requirement is applied in metric terms.3 Components3.1 Except as indicated in 3.2, a component (inc
9、luding gaskets and polymeric materials) of a productcovered by this outline of investigation shall comply with the requirements for that component.3.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the
10、 component in theproduct covered by this outline of investigation, orb) Is superseded by a requirement in this outline of investigation.3.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.3.4 Specific components are incomplete in construction fea
11、tures or restricted in performance capabilities.Such components are intended for use only under limited conditions, such as certain temperatures notexceeding specified limits, and shall be used only under those specific conditions.SEPTEMBER 14, 2010SUBJECT 27334UL COPYRIGHTED MATERIAL NOT AUTHORIZED
12、 FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL4 Undated References4.1 Any undated reference to a code or standard appearing in the requirements of this outline ofinvestigation shall be interpreted as referring to the latest edition of that code or standard.CONSTRUCTION5 Material
13、s and Workmanship5.1 Only materials that are acceptable for the particular use shall be employed in a cable. Cables shallbe made and finished with the degree of uniformity and grade of workmanship that are practicable in awell-equipped factory.5.2 Each material used in a cable shall be compatible wi
14、th all of the other materials used in the cable.6 General6.1 Assembly6.1.1 These cables consist of a single insulated conductor or a single, coaxial cable.6.1.2 Each coaxial cable shall consist of a single central conductor covered in turn with solid or foamedinsulation (with or without a skin) comp
15、lying (including thicknesses) with Insulation, 6.3; a shield complyingwith Shield, 6.4; and a jacket complying with Jacket, 6.5.6.2 Conductors6.2.1 Conductors shall be solid or stranded. Conductors 18 4/0 AWG in size shall comply with the 0.98X Nominal minimum area column as shown in Table 20.1 of t
16、he Reference Standard for Electrical Wires,Cables, and Flexible Cords, UL 1581. Conductors 0.75 95 mm2in size shall comply shall comply withthe requirements in Table 6.1. Conductors shall consist of copper in accordance with the StandardSpecification for Soft or Annealed Copper Wire, ASTM B3, the St
17、andard Specification for Tinned Soft orAnnealed Copper Wire for Electrical Purposes, ASTM B33, the Standard Specification for Silver-CoatedSoft or Annealed Copper Wire, ASTM B298, or the Standard Specification for Nickel-Coated Soft orAnnealed Copper Wire, ASTM B355. The conductor stranding is not d
18、efined, but shall be judged basedon compliance of the cable with the test program in Section 7.SEPTEMBER 14, 2010 SUBJECT 2733 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULTable 6.1Metric conductor sizesSize of conductor, mm2Minimum cross-
19、sectional area, mm20.75 0.7351 0.981.5 1.472 1.962.5 2.454 3.926 5.8810 9.816 15.725 24.535 34.350 49.070 68.695 93.16.3 Insulation6.3.1 The insulation material shall be one described in the Tables in Section 50 of the ReferenceStandard for Electrical Wires, Cables, and Flexible Cords, UL 1581, suit
20、able for the temperature rating ofthe cable. Regardless of what is noted in the Table, the minimum unaged tensile strength value shall be8.27 MPa (1200 psi).6.3.2 The insulation shall be solid in form and shall be extruded directly over the conductor.6.3.3 The insulation used in a coaxial cable may
21、be foamed. Foamed insulation does not need to complywith the minimum tensile strength noted in 6.3.1.6.3.4 The insulation thickness shall not be less than the thicknesses shown in Table 6.2 and shall bejudged based on compliance of the cable with the test program in Section 7.Table 6.2Insulation and
22、 jacket wall thicknessAWG size Metric size, mm2Minimum average wallthickness, milsMinimum wall thickness atany point, mils18 16 0.75 1.0 8 714 12 1.5 2.5 10 9106 410 15 1342 1625 25 233550451/0 2/0 50 70 60 543/0 4/0 95 65 596.4 Shield6.4.1 A shield shall be of metal and shall consist of one or more
23、 of the following, but otherwise is notspecified:SEPTEMBER 14, 2010SUBJECT 27336UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULa) A laminated shield tape of polymeric material and metal(s) with or without a metal coated oruncoated (uncoated n
24、ot acceptable with an aluminum-faced tape) copper or copper alloy drainwire in contact with the metal(s) part of the tape. The tape may be applied with the metal(s)side in or out. The size of a drain wire is not specified. A drain wire may be solid or stranded.b) A serving, wrap, or braid of coated
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT27332010OUTLINEOFINVESTIGATIONFORSURFACEVEHICLEONBOARDCABLEISSUE2SUBJECT2733 水面 航行 车载 电缆 调查

链接地址:http://www.mydoc123.com/p-1069334.html