UL SUBJECT 2367-2004 OUTLINE OF INVESTIGATION FOR SOLID STATE OVERCURRENT PROTECTORS (Issue 1)《固态过流保护器调查大纲 发布编号 1》.pdf
《UL SUBJECT 2367-2004 OUTLINE OF INVESTIGATION FOR SOLID STATE OVERCURRENT PROTECTORS (Issue 1)《固态过流保护器调查大纲 发布编号 1》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 2367-2004 OUTLINE OF INVESTIGATION FOR SOLID STATE OVERCURRENT PROTECTORS (Issue 1)《固态过流保护器调查大纲 发布编号 1》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、May 13, 20041SUBJECT 2367OUTLINE OF INVESTIGATIONFORSOLID STATE OVERCURRENT PROTECTORSIssue Number 1May 13, 2004Summary of TopicsThis is the First Issue of the Outline of Investigation for Solid StateOvercurrent Protectors, Subject 2367.The UL Foreword is no longer located within the UL Standard. Fo
2、r informationconcerning the use and application of the requirements contained in thisStandard, the current version of the UL Foreword is located onULStandardsInfoNet at: http:/ 2004 UNDERWRITERS LABORATORIES INC.MAY 13, 2004SUBJECT 23672No Text on This PageCONTENTSINTRODUCTION1 Scope .42 Components
3、53 Units of Measurement .54 Undated References 55 Glossary .5CONSTRUCTION6 General 67 Insulating Materials 68 Live Parts 69 Corrosion Protection .6PERFORMANCE10 Calibration Tests .611 Temperature Test 812 Overload Operation Test 913 Short Circuit Test 914 Shipping and Storage Test 915 Thermal Cyclin
4、g Test 1016 Endurance Test 1017 Abnormal Test 1118 Long Term Abnormal Test .11MANUFACTURING AND PRODUCTION TESTS19 Production Line Test 11RATING20 General 11MARKING21 General 12MAY 13, 2004 SUBJECT 2367 3INTRODUCTION1 Scope1.1 This Outline of Investigation covers solid-state overcurrent protectors.
5、These devices are solid-stateswitches that limit the output current to a safe level when the output load exceeds the current-limitthreshold or when a load-side short-circuit is present. Solid-state overcurrent protectors are intended tobe used on the load-side of an isolating transformer, power supp
6、ly or battery to provide a means ofsupplementary protection. See Table 1.1 for maximum current and power levels.Table 1.1Maximum current and power levelsOutput voltage (Voc) Output current (Isc)VacVdcA(VA) 20 20 1000 / Voc 25020 Voc 30 20 Voc 30 1000 / Voc 25030oc 60 1000 / Voc 2501.2 The devices co
7、vered by these requirements are integrated circuits, and electrical spacings within thedevices are not specified.1.3 The devices covered by these requirements are entirely electronic in nature and have no means formanual operation or reset.1.4 The terminals of the devices covered by these requiremen
8、ts are for factory wiring only (intended tobe mounted on a printed wiring board).1.5 The devices covered by these requirements shall only be used on supply circuits originating from anisolating transformer, a power supply or a battery with limited maximum current and power levels as notedin Table 1.
9、1. Use on supply circuits with a higher power capability requires additional evaluation forreliability, such as those requirements contained in the Standard for Safety-Related Controls EmployingSolid-State Controls, UL 991.1.6 The devices covered by these requirements limit output currents to values
10、 less than the overcurrentprotection rating of 5 amperes.1.7 The devices covered by these requirements have only been evaluated for supplementary overcurrentprotection of secondary circuits supplied by the load side of a transformer, power supply or battery andhave not been evaluated for branch-circ
11、uit protection.1.8 This Outline of Investigation may cover devices intended for use in telecommunications applications.However, devices intended for connection to telecommunications networks with outside plant connectionsshould be evaluated in the end-use in accordance with the requirements of the S
12、tandard for TelephoneEquipment, UL 1459, the Standard for Secondary Protectors for Communication Circuits, UL 497A, or theStandard for Information Technology Equipment, UL 60950 as appropriate.MAY 13, 2004SUBJECT 236742 Components2.1 The devices covered by this outline are components. They are incom
13、plete in certain constructionalfeatures or restricted in performance capabilities and are intended for use as components of completeequipment rather than for separate installation in the field.2.2 A component shall be used in accordance with its rating established for the intended conditions ofuse.2
14、.3 Components that are intended for use only under limited conditions, such as certain temperatures notexceeding specified limits shall be used only under those specific conditions.3 Units of Measurement3.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory
15、orapproximate information.4 Undated References4.1 Any undated reference to a code or standard appearing in the requirements of this Outline ofInvestigation shall be interpreted as referring to the latest edition of that code or standard.5 Glossary5.1 For the purpose of this outline, the following de
16、finitions apply:5.2 EXPOSED PLANT (OUTSIDE PLANT) Any portion of the telecommunications network subject toaccidental contact with or induction from power conductors at a voltage exceeding 300V to ground. Thisincludes circuitry that is intended to be connected to the Public Switched Telephone Network
17、 (PST-N),Off-Premises Extension (OPE) lines, and the like.5.3 MAXIMUM CONTINUOUS CURRENT (CONT. CURRENT) This designation is the ampere ratingfor which a protector or family of protectors has been tested for continuous current operation.5.4 PROTECTIVE CURRENT (PROT. CURRENT) This designation is the
18、ampere rating for which aprotector or family of protectors has been tested for providing overcurrent protection.5.5 TELECOMMUNICATION (TELEPHONE) NETWORK CIRCUIT An electrical circuit conductivelyconnected to the telephone company communications facilities.5.6 TELECOMMUNICATION NETWORK CONNECTIONS (
19、TNC) Identified as follows:a) Not intended for use on telecommunication network with outside plant connections.b) Intended for use on telecommunication network with outside plant connections.5.7 VOLTAGE RANGE (VOLTS) This designation is the voltage range for which a protector or family ofprotectors
20、has been tested. Unless specified otherwise, all voltages are direct current (DC).MAY 13, 2004 SUBJECT 2367 5CONSTRUCTION6 General6.1 A solid-state overcurrent protector shall be constructed in compliance with Sections79.7 Insulating Materials7.1 Uninsulated live parts involving risk of fire, electr
21、ic shock or electrical-energy/high-current levels shallbe mounted on porcelain, phenolic-composition or other material that is intended for the application.7.2 Thermoplastic materials used for the direct or indirect support of uninsulated live parts involving a riskof fire, electric shock, or electr
22、ical-energy/high-current shall comply with the requirements in the Standardfor Polymeric Materials Use in Electrical Equipment Evaluations, UL 746C.7.3 Molded parts shall have the mechanical strength and rigidity to withstand the stresses of actualservice.8 Live Parts8.1 Metal employed for current-c
23、arrying parts shall be of stainless steel, silver, gold, copper, nickel,aluminum, an alloy of the same, or an equivalent material.9 Corrosion Protection9.1 Iron and steel parts shall be protected against corrosion by enameling, galvanizing, plating, or otherequivalent means.Exception: Encapsulated p
24、arts and stainless steel parts need not be provided with plating.PERFORMANCE10 Calibration Tests10.1 A Solid State Overcurrent Protector shall operate in accordance with the parameters shown inTables 10.1 and 10.2. There shall be no emission of flame or molten metal from the device during testingor
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT23672004OUTLINEOFINVESTIGATIONFORSOLIDSTATEOVERCURRENTPROTECTORSISSUE1 固态 保护 调查 大纲 发布 编号 PDF

链接地址:http://www.mydoc123.com/p-1069273.html