1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMAY 24, 20161UL 1488Outline of Investigation for Seasonal Use Modular TreesIssue Number: 3May 24, 2016Summary of TopicsThis third issue of the Outline of Investigation for Seasonal Use ModularTre
2、es, UL 1488, contains revisions to requirements for supplyconnections, cords, lighting string segment, leakage current andcarton/stuffer sheet/product/cord tag markings.ULs Outlines of Investigation are copyrighted by UL LLC. Neither a printed norelectronic copy of an Outline of Investigation should
3、 be altered in any way. All ofULs Outlines of Investigation and all copyrights, ownerships, and rights regardingthose Outlines of Investigation shall remain the sole and exclusive property of ULLLC.COPYRIGHT 2016 UL LLCUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WI
4、THOUT PERMISSION FROM ULMAY 24, 2016UL 14882No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .52 Glossary .53 Components 64 Units of Measurement .65 References .6CONSTRUCTION6 General .67 Supply C
5、onnections .78 Cords 79 Internal Wiring 810 Lighting String Segment 810.1 General .810.2 Lamps .910.3 Lamping 910.4 Polarization .911 Fuseholders and Fused Attachment Plugs .1012 Wiring Devices .1212.1 Power inlet box or similar construction .1212.2 Tree pole segment connectors .1413 Terminals and C
6、onductive Parts 1414 Overcurrent Protection 1415 Switches .1516 Class 2 Circuits .1517 Mechanical Assembly .1618 Materials 1719 Enclosures .1719.1 General 1719.2 Metallic enclosures .1819.3 Polymeric enclosures .1820 Accessibility of Live Parts 1821 Spacing .1922 Printed Wiring Boards .1923 Enclosur
7、e Opening 2024 Bushing .2025 Strain Relief 21PERFORMANCE26 Leakage Current 2127 Leakage Current Following Humidity Conditioning 2328 Input Test 2429 Temperature Test .2430 Dielectric Voltage-Withstand Test .2731 Strain Relief Test .2732 Abnormal Operation Test 2833 Downward Burning Rate Test 29MAY 2
8、4, 2016 UL 1488 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL34 Conductivity of Decorative Parts Test .3035 Enclosure Mold Stress Relief Test .3036 Impact Test .3137 Resistance to Crushing Test .3438 Adhesive Test 34PRODUCTS EMPLOYING CORD
9、-CONNECTED WIRING DEVICES OR POWER INLETS39 General 3540 Strain Relief Test .3541 Reliability of Conductor Connections Test .3542 Security of Blades Test 3643 Security of Input Contacts Test .3644 Security of Insulation Test .3645 Accessibility Test .3746 Fuseholder Temperature Test 3747 Stability T
10、est 39RATINGS48 Details .39MARKING49 General 3950 Cord Tag Markings .4051 Carton/Stuffer Sheet/Product/Cord Tag Markings 4251.1 General .4251.2 Carton markings .42INSTRUCTION MANUAL52 General 42APPENDIX AStandards for ComponentsA1MAY 24, 2016UL 14884UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER
11、 REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 This outline covers temporary Indoor Use Seasonal Use Modular trees (“Modular Tree”) and TreePoles optionally provided with factory-assembled lighting strings or segments (incandescent or LED)and/or other decorative featur
12、es, with a maximum input voltage rating of 120 V to be used in accordancewith the National Electrical Code, ANSI/NFPA 70. Temporary-use is considered to be a period ofinstallation and use not exceeding 90 days.1.2 These requirements do not cover decorative lighting strings or other seasonal products
13、 that arecovered under the Standard for Seasonal and Holiday Decorative Products, UL 588.1.3 The complete modular tree shall additionally comply with the Outline of Investigation for Fire Tests ofPre-Lit Artificial Seasonal Use Trees and Other Seasonal Decorative Items, UL 2358.2 Glossary2.1 CLASS 2
14、 CIRCUIT A circuit powered from the output of a Class 2 transformer or a Class 2 powerunit. Refer to Section 16 for detailed information.2.2 CONNECTORS, TREE POLE SEGMENT Connecting couplers installed within tree pole providingelectrical and physical connection between tree pole segments.2.3 INTERCO
15、NNECTING CORDS Length of cord with a minimum of one nonstandard fitting intendedfor connecting multiple modules.2.4 LIGHTING STRING SEGMENT Lighting strings that are provided with nonstandard fittings orintended for direct wiring to a tree pole or modular tree.2.5 MODULAR TREE A complete artificial
16、pre-lit tree that may or may not be provided with modules.2.6 MODULES Units or sections that can be added or removed. Examples include flasher controllers,music boxes and the like, and means for connection to source of supply.2.7 SHUNT, LAMP A device used in series-connected lamps to provide a curre
17、nt path when thefilament of a lamp opens so that the remaining lamps in the series-connected string or decorative outfitremain illuminated. A shunt typically consists of several turns of aluminum wire wound around the pair offilament support posts. The aluminum oxide coating on the wire acts as an i
18、nsulator, allowing current tonormally flow through the filament. When the filament of the lamp opens, a high voltage (approximately120 V) is present across the support posts causing the oxide coating of the shunt to break down. Theshunt then becomes electrically connected to the support posts and al
19、lows current to continue to flowthrough the shunt despite the open filament.MAY 24, 2016 UL 1488 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3 Components3.1 Except as indicated in 3.2, a component of a product covered by this outline shal
20、l comply with therequirements for that component. See Appendix A for a list of standards covering components generallyused in the products covered by this outline.3.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the ap
21、plication of the component in theproduct covered by this outline, orb) Is superseded by a requirement in this outline.3.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.3.4 Specific components are incomplete in construction features or restricte
22、d in performance capabilities.Such components are intended for use only under limited conditions, such as certain temperatures notexceeding specified limits, and shall be used only under those specific conditions.4 Units of Measurement4.1 Values stated without parentheses are the requirement. Values
23、 in parentheses are explanatory orapproximate information.5 References5.1 Any undated reference to a code or standard appearing in the requirements of this outline shall beinterpreted as referring to the latest edition of that code or standard.CONSTRUCTION6 General6.1 If a product employs a componen
24、t or another product as part of its construction, each part of theproduct shall comply with its applicable construction requirements. For example, if a modular tree employsa lighting string and controller, then construction requirements for a lighting string and controller shall allbe applicable.MAY
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT14882016OUTLINEOFINVESTIGATIONFORSEASONALUSEMODULARTREESISSUE3PDF

链接地址:http://www.mydoc123.com/p-1069177.html