UL SUBJECT 1488-2015 UL Outline for Investigation Seasonal Use Modular Trees (Issue 2)《季节性使用模块化树的UL调查大纲 (议题2)》.pdf
《UL SUBJECT 1488-2015 UL Outline for Investigation Seasonal Use Modular Trees (Issue 2)《季节性使用模块化树的UL调查大纲 (议题2)》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 1488-2015 UL Outline for Investigation Seasonal Use Modular Trees (Issue 2)《季节性使用模块化树的UL调查大纲 (议题2)》.pdf(46页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULAPRIL 27, 20151UL 1488Outline of Investigation for Seasonal Use Modular TreesIssue Number: 1April 27, 2015Summary of TopicsThis first issue of the Outline of Investigation for Seasonal Use Modula
2、rTrees, UL 1488, covers temporary Indoor Use Seasonal Use Modular trees(“Modular Tree”) and Tree Poles optionally provided with factory-assembled lighting strings or segments (incandescent or LED) and/orother decorative features, with a maximum input voltage rating of 120 V tobe used in accordance w
3、ith the National Electrical Code, ANSI/NFPA 70.Temporary-use is considered to be a period of installation and use notexceeding 90 days.ULs Outlines of Investigation are copyrighted by UL. Neither a printed norelectronic copy of an Outline of Investigation should be altered in any way. All ofULs Outl
4、ines of Investigation and all copyrights, ownerships, and rights regardingthose Outlines of Investigation shall remain the sole and exclusive property of UL.COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION
5、FROM ULAPRIL 27, 2015UL 14882No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .52 Glossary .53 Components 64 Units of Measurement .65 References .6CONSTRUCTION6 General .67 Supply Connections .78
6、Cords 79 Internal Wiring 810 Lighting String Segment 810.1 General .810.2 Lamps .910.3 Lamping 910.4 Polarization .911 Fuseholders and Fused Attachment Plugs 912 Wiring Devices .1112.1 Power inlet box or similar construction .1112.2 Tree pole segment connectors .1313 Terminals and Conductive Parts 1
7、314 Overcurrent Protection 1315 Switches .1416 Class 2 Circuits .1417 Mechanical Assembly .1518 Materials 1619 Enclosures .1619.1 General 1619.2 Metallic enclosures .1719.3 Polymeric enclosures .1720 Accessibility of Live Parts 1721 Spacing .1822 Printed Wiring Boards .1823 Enclosure Opening 1924 Bu
8、shing .1925 Strain Relief 20PERFORMANCE26 Leakage Current 2027 Leakage Current Following Humidity Conditioning 2228 Input Test 2329 Temperature Test .2330 Dielectric Voltage-Withstand Test .2631 Strain Relief Test .2632 Abnormal Operation Test 2733 Downward Burning Rate Test 28APRIL 27, 2015 UL 1488
9、 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL34 Conductivity of Decorative Parts Test .2935 Enclosure Mold Stress Relief Test .2936 Impact Test .3037 Resistance to Crushing Test .3338 Adhesive Test 33PRODUCTS EMPLOYING CORD-CONNECTED WIRI
10、NG DEVICES OR POWER INLETS39 General 3440 Strain Relief Test .3441 Reliability of Conductor Connections Test .3442 Security of Blades Test 3543 Security of Input Contacts Test .3544 Security of Insulation Test .3545 Accessibility Test .3646 Fuseholder Temperature Test 3647 Stability Test 38RATINGS48
11、 Details .38MARKING49 General 3850 Cord Tag Markings .3951 Carton/Stuffer Sheet/Product/Cord Tag Markings 4051.1 General .4051.2 Carton markings .41INSTRUCTION MANUAL52 General 41APPENDIX AStandards for ComponentsA1APRIL 27, 2015UL 14884UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION
12、 ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 This outline covers temporary Indoor Use Seasonal Use Modular trees (“Modular Tree”) and TreePoles optionally provided with factory-assembled lighting strings or segments (incandescent or LED)and/or other decorative features, with a ma
13、ximum input voltage rating of 120 V to be used in accordancewith the National Electrical Code, ANSI/NFPA 70. Temporary-use is considered to be a period ofinstallation and use not exceeding 90 days.1.2 These requirements do not cover decorative lighting strings or other seasonal products that arecove
14、red under the Standard for Seasonal and Holiday Decorative Products, UL 588.1.3 The complete modular tree shall additionally comply with the Outline of Investigation for Fire Tests ofPre-Lit Artificial Seasonal Use Trees and Other Seasonal Decorative Items, UL 2358.2 Glossary2.1 CLASS 2 CIRCUIT A ci
15、rcuit powered from the output of a Class 2 transformer or a Class 2 powerunit. Refer to Section 16 for detailed information.2.2 CONNECTORS, TREE POLE SEGMENT Connecting couplers installed within tree pole providingelectrical and physical connection between tree pole segments.2.3 INTERCONNECTING CORD
16、S Length of cord with a minimum of one nonstandard fitting intendedfor connecting multiple modules.2.4 LIGHTING STRING SEGMENT Lighting strings that are provided with nonstandard fittings orintended for direct wiring to a tree pole or modular tree.2.5 MODULAR TREE A complete artificial pre-lit tree
17、that may or may not be provide with modules.2.6 MODULES Units or sections that can be added or removed. Examples include flasher controllers,music boxes and the like, and means for connection to source of supply.2.7 SHUNT, LAMP A device used in series-connected lamps to provide a current path when t
18、hefilament of a lamp opens so that the remaining lamps in the series-connected string or decorative outfitremain illuminated. A shunt typically consists of several turns of aluminum wire wound around the pair offilament support posts. The aluminum oxide coating on the wire acts as an insulator, allo
19、wing current tonormally flow through the filament. When the filament of the lamp opens, a high voltage (approximately120 V) is present across the support posts causing the oxide coating of the shunt to break down. Theshunt then becomes electrically connected to the support posts and allows current t
20、o continue to flowthrough the shunt despite the open filament.APRIL 27, 2015 UL 1488 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3 Components3.1 Except as indicated in 3.2, a component of a product covered by this outline shall comply wit
21、h therequirements for that component. See Appendix A for a list of standards covering components generallyused in the products covered by this outline.3.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of
22、 the component in theproduct covered by this outline, orb) Is superseded by a requirement in this outline.3.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.3.4 Specific components are incomplete in construction features or restricted in perform
23、ance capabilities.Such components are intended for use only under limited conditions, such as certain temperatures notexceeding specified limits, and shall be used only under those specific conditions.4 Units of Measurement4.1 Values stated without parentheses are the requirement. Values in parenthe
24、ses are explanatory orapproximate information.5 References5.1 Any undated reference to a code or standard appearing in the requirements of this outline shall beinterpreted as referring to the latest edition of that code or standard.CONSTRUCTION6 General6.1 If a product employs a component or another
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT14882015ULOUTLINEFORINVESTIGATIONSEASONALUSEMODULARTREESISSUE2 季节性 使用 模块化 UL 调查 大纲 议题 PDF

链接地址:http://www.mydoc123.com/p-1069176.html