UL 917 CRD-2012 UL Standard for Safety Clock-Operated Switches - Section Paragraph Reference 41 2 Subject Abnormal Switching Test - Requirements for controls using electronic triggi.pdf
《UL 917 CRD-2012 UL Standard for Safety Clock-Operated Switches - Section Paragraph Reference 41 2 Subject Abnormal Switching Test - Requirements for controls using electronic triggi.pdf》由会员分享,可在线阅读,更多相关《UL 917 CRD-2012 UL Standard for Safety Clock-Operated Switches - Section Paragraph Reference 41 2 Subject Abnormal Switching Test - Requirements for controls using electronic triggi.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): WGZRStandard Number: UL 917Edition Date: November 10, 2006Edition Number: 5Section / Paragraph Reference: 41.2Subject: Abnormal Switching Test - Requirements
3、 for controls using electronictriggering techniques, such as zero-crossing switching, to switch the controlsoutput switching device.DECISION:41 Abnormal Operation Test41.1 Adverse conditions of operation41.1.1 When tested in accordance with 41.1.2, there shall not be ignition of the enclosure materi
4、al,exposure of live parts, emission of flame or molten metal, nor glowing or flaming of the material uponwhich the equipment is mounted. The disturbance shall be confined by the enclosure. The disturbanceshall not result in a risk of fire, electric shock, or injury to persons; in parts to become acc
5、essible; or inreduction of spacings to below the required levels.41.1.2 The equipment is to be operated under the most adverse condition of abnormal operation such asstalled-rotor, blocked-armature of relay, burnout of transformer or operation with current-carrying partsshort-circuited, and the like
6、. During the test, the equipment is to rest on white tissue paper on a softwoodsurface and is to be operated continuously until the ultimate results have been determined. In most cases,continuous operation will be necessary until constant temperatures are reached.41.2 Abnormal Switching Test41.2.1 C
7、ontrols incorporating electronic circuitry to trigger the switching device during a moreadvantageous electrical condition, such as at zero crossing, shall be subjected to this abnormal switchingtest. This test is applicable when:a) Loads and circuits are non-safety.b) Switching components are used b
8、eyond their ratings.41.2.2 Two test samples are prepared and connected as follows:a) The trigger circuit of the switching device is to be removed or modified to allow randomswitching.b) A ground arc indicating fuse is connected to accessible dead metal of the control. Theground arc detection fuse sh
9、all be rated not greater than 3A and not less than the workingvoltage.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULc) The control shall be covered in a single layer of cheesecloth except the mounting surface,and then placed on a softwood su
10、rface that has been covered with white tissue paper. Thecheesecloth shall be, bleached untreated cotton cloth running 14 15 square yards per pound(26 28m2/kg) and for any square inch a count of 32 threads in one direction and 28 in theother direction (for any square centimeter, 13 threads in one dir
11、ection and 11 in the otherdirection).d) The rated supply shall be connected through a Branch Circuit Protection device sizedaccording to installation requirements.e) The control is connected to its rated electrical load.41.2.3 The prepared test samples shall be operated in accordance with the endura
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL917CRD2012ULSTANDARDFORSAFETYCLOCKOPERATEDSWITCHESSECTIONPARAGRAPHREFERENCE412SUBJECTABNORMALSWITCHINGTESTREQUIREMENTSFORCONTROLSUSINGELECTRONICTRIGGIPDF

链接地址:http://www.mydoc123.com/p-1069048.html