《UL 60947-7-2 (ND)-2017 National Differences For Low-Voltage Switchgear and Controlgear C Part 7-2 Ancillary Equipment C Protective Conductor Terminal Blocks for Copper Conductors (.pdf》由会员分享,可在线阅读,更多相关《UL 60947-7-2 (ND)-2017 National Differences For Low-Voltage Switchgear and Controlgear C Part 7-2 Ancillary Equipment C Protective Conductor Terminal Blocks for Copper Conductors (.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForLow-Voltage Switchgear and Controlgear Part 7-2: Ancillary Equipment Protective ConductorTerminal Blocks for Copper ConductorsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FU
2、RTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForLow-Voltage Switchgear and Controlgear Part 7-2: Ancillary Equipment Protective ConductorTerminal Blocks for Copper ConductorsFourth EditionEdition Date: January 27, 2017This revision of ANSI/UL 60947-7-2 is to revis
3、e the National Differences to include Canada. Thisstandard is harmonized for Canada, Mexico and the United States and co-published by all threestandards development organizations (CSA Group, ANCE and UL).This document provides a single listing of the National Differences included in the UL adoption
4、ofthe corresponding IEC standard.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwisewithout prior permission of UL.UL provides this standards document as
5、 is without warranty of any kind, either expressed or implied,including but not limited to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be liable for any special, incidental, consequential, indirect or similar damages,including loss of profits, lost savin
6、gs, loss of data, or any other damages arising out of the use of or theinability to use this standards document, even if UL or an authorized UL representative has been advisedof the possibility of such damage. In no event shall ULs liability for any damage ever exceed the pricepaid for this standard
7、s document, regardless of the form of the claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonableattorneys fees) resulting from any error or devi
8、ation introduced while purchaser is storing an electronicStandard on the purchasers computer system.Copyright 2017 Underwriters Laboratories Inc.JANUARY 27, 2017NATIONAL DIFFERENCES FOR2UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceTh
9、is document provides a single listing of the technical National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standards, UL uses the notations indicated below to identify national difference type, andthese types are additionally noted in this document. The
10、 standard may not use all types of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirements, elimination ofwhich would compromise safety for U.S. consumers and users of products.D2 - These are deviations based on safety practices. These are deviations for
11、 IEC requirements that maybe acceptable, but adopting the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - These are deviations based on the component standards and will not be deleted until a particularcomponent standard is harmonized with the IEC comp
12、onent standard.DE - These are deviations based on editorial comments or corrections.DR - These are deviations based on the national regulatory requirements.Each national difference contains a description of what the national difference entails. Typically one of thefollowing words is used to explain
13、how the text of the national difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause, table, figure,or annex. Addition is not meant to include adding select words to the base IEC text.Deletion / Delete - A deletion entails
14、 complete deletion of an entire numbered clause, subclause, table,figure, or annex without any replacement text.Modification / Modify - A modification is an altering of the existing base IEC text such as the addition,replacement or deletion of certain words or the replacement of an entire clause, su
15、bclause, table, figure,or annex of the base IEC text.JANUARY 27, 2017 NATIONAL DIFFERENCES FOR 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences1.1DV.1 D2 Modification of Clause 1.1:Replace “0,2 mm2and 120 mm2(AWG 24 and 25
16、0 kcmil)” with “0,1 mm2and 120 mm2(AWG 30 and 250 kcmil)”.1.1DV.2 D2 Modification by adding the following:This standard applies to insulation displacement terminals.1.1DV.3 DR Modification by adding the following:Terminal blocks with PEN function are not permitted.1.1DV.4 D2 Modification by adding t
17、he following:This standard also applies to terminal blocks that have insulation piercing or displacementclamping units.1.1DV.5 D2 Modification by adding the following:This standard specifies requirements for protective conductor terminal blocks with PEfunction up to 120 mm2(250 kcmil) and for protec
18、tive conductor terminal blocks with PENfunction equal to and above 10 mm2(AWG 8) with screw-type or screwless-type clampingunits, primarily intended for industrial applications, in accordance with Annex DVB of item1 in Annex DVA, National Electrical Code, NFPA 70 (for use in the USA), CSA C22.1-15Ca
19、nadian Electrical Code, Part I (for use in Canada), or NOM-001-SEDE, ElectricalInstallations (Utility) for use in Mexico.1.2DV D1 Modification by adding the followingSee Annex DVA for Canada, Mexico, and USA Standard References.2.2DV D2 Modification by adding the following:It is mechanically and ele
20、ctrically attached to its support, path 2-2 in Figure 5. In somecases it will have path 1-1, and in other cases it will not.2.3DV DR Delete Clause 2.3:This definition does not apply.3DV.1 D2 Modification by adding the following dashed item to the list:application: commercial and industrial, or servi
21、ceJANUARY 27, 2017NATIONAL DIFFERENCES FOR4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3DV.2 DR Modification by replacing the seventh dashed item in the list with thefollowing: PE functions.3DV.3 D3 Modification by adding the following:In
22、Canada, the general requirements applicable to this Standard are provided inCAN/CSA-C22.2 No. 0.4.3.2DV D2 Modification by adding the following:A protective conductor terminal block, classified for use as an unprotected circuit, shall besubjected to the Short-time withstand current test for Service
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL6094772ND2017NATIONALDIFFERENCESFORLOWVOLTAGESWITCHGEARANDCONTROLGEARCPART72ANCILLARYEQUIPMENTCPROTECTIVECONDUCTORTERMINALBLOCKSFORCOPPERCONDUCTORSPDF

链接地址:http://www.mydoc123.com/p-1068607.html