UL 574 CRD-2013 UL Standard for Safety Electric Oil Heaters - Section Paragraph Reference Sections 9 and 26 Subject Subdivided circuits for heating elements (Edition 8 August 14 2.pdf
《UL 574 CRD-2013 UL Standard for Safety Electric Oil Heaters - Section Paragraph Reference Sections 9 and 26 Subject Subdivided circuits for heating elements (Edition 8 August 14 2.pdf》由会员分享,可在线阅读,更多相关《UL 574 CRD-2013 UL Standard for Safety Electric Oil Heaters - Section Paragraph Reference Sections 9 and 26 Subject Subdivided circuits for heating elements (Edition 8 August 14 2.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): MDSTStandard Number: UL 574Standard Title: Standard for Electric Oil HeatersEdition Date: August 14, 2003Edition Number: 8Section / Paragraph Reference: Sect
3、ions 9 and 26Subject: Subdivided circuits for heating elementsDECISION:(New text is underlined, deleted text is indicated by strikethrough)9 Overload Protection9.1 A fuseholder or circuit breaker provided as a part of a heater shall not be accessible from the outsideof the oil heater without opening
4、 a door or cover, except that the operating handle of a circuit breaker mayproject outside of the enclosure. A plug-fuseholder shall be installed so that uninsulated live parts otherthan the screw shell and center contact will not be exposed to contact by persons removing or replacingfuses.9.2 An oi
5、l heater rated more than 48 amperes and employing resistance heating elements shall have theheating elements on subdivided circuits. Each subdivided load shall not exceed 48 amperes and shall beprotected at no more than 60 amperes.Exception: An oil heater employing a resistance type immersion electr
6、ic heating element contained in avessel marked with an appropriate ASME symbol may be subdivided into circuits not exceeding 120amperes and protected at no more than 150 amperes.9.3 The overcurrent protection devices required in 9.2 shall be provided by the manufacturer as an integralpart of the oil
7、 heater or shall be provided by the manufacturer as a separate assembly for independentmounting for use with the oil heater. When the overcurrent protection devices are provided as a separateassembly, the oil heater and the overcurrent protection assembly shall be marked as required in 26.14and 26.1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL574CRD2013ULSTANDARDFORSAFETYELECTRICOILHEATERSSECTIONPARAGRAPHREFERENCESECTIONS9AND26SUBJECTSUBDIVIDEDCIRCUITSFORHEATINGELEMENTSEDITION8AUGUST142PDF

链接地址:http://www.mydoc123.com/p-1068319.html