《UL 448B-2008 UL Standard for Safety Residential Fire Pumps Intended for One- and Two-Family Dwellings and Manufactured Homes (First Edition Reprint with Revisions Through and Inclu.pdf》由会员分享,可在线阅读,更多相关《UL 448B-2008 UL Standard for Safety Residential Fire Pumps Intended for One- and Two-Family Dwellings and Manufactured Homes (First Edition Reprint with Revisions Through and Inclu.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 448B Residential Fire Pumps Intended for One- and Two-Family Dwellings and Manufactured HomesUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSIO
2、N FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Residential Fire Pumps Intended for One- and Two-Family Dwellings and Manufactured Homes, UL 448B First Edition, Dated December 23, 2008 Summary of Topics Th
3、ese revisions to the First Edition of ANSI/UL 448B include the following changes in requirements: Clarify and Update Requirements Related to Pump Construction and Performance Testing Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical li
4、ne in the margin. Changes in requirements are marked with a vertical line in the margin and are followed by an effective date note indicating the date of publication or the date on which the changed requirement becomes effective. The new requirements are substantially in accordance with Proposal(s)
5、on this subject dated June 7, 2013. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is
6、without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, l
7、oss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless
8、 of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced wh
9、ile purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the aff
10、ected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. AUGUST 28, 2013 UL 448B tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WI
11、THOUT PERMISSION FROM UL AUGUST 28, 2013 UL 448B tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL DECEMBER 23, 2008 (Title Page Reprinted: August 28, 2013) 1 UL 448B Standard for Residential Fire Pumps Intended for One
12、- and Two-Family Dwellings and Manufactured Homes Prior to the rst edition, the requirements for the products covered by this standard were included in the Outline of Investigation for Residential Fire Pumps Intended for One- and Two-Family Dwellings and Manufactured Homes, SU 448B. First Edition De
13、cember 23, 2008 This ANSI/UL Standard for Safety consists of the First Edition including revisions through August 28, 2013. The most recent designation of ANSI/UL 448B as an American National Standard (ANSI) occurred on August 27, 2013. The ANSI approval for this standard does not include the Cover
14、Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs
15、 Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2013 UNDERWRITERS LAB
16、ORATORIES INC. ANSI/UL 448B-2013UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL DECEMBER 23, 2008 UL 448B 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTEN
17、TS INTRODUCTION 1 Scope .4 2 Components 4 3 Units of Measurement 4A 4 Undated References .4A 5 Glossary 4A CONSTRUCTION 6 General 6 7 Pump Casings 9 8 Impellers, Rings, and Other Internal Components .9 9 Ball and Roller Bearings 10 10 Shaft Seals 11 PERFORMANCE 11 Operation Test .12 12 Hydrostatic S
18、trength Test 13 13 Plastic Impellers or Other Internal Primary Pump Components (Except Bushings, Seal Rings, Coatings and Similar Components) .13 13.1 Air oven aging .13 13.2 Water aging .14 14 Maximum Operating Temperature Test 14 MANUFACTURING AND PRODUCTION TESTS 15 General 15 MARKINGS 16 General
19、 15 DECEMBER 23, 2008 UL 448B 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover re pumps intended for use in water-supply systems for one- and two-family dwellings and manufactured homes. 1.1
20、effective December 23, 2010 1.2 The pumps covered by these requirements are intended for installation and use in accordance with the Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes, NFPA 13D. 1.2 effective December 23, 2010 2 Components 2.1
21、Except as indicated in 2.2, a component of a product covered by this standard shall comply with the requirements for that component. 2.1 effective December 23, 2010 2.2 A component is not required to comply with a specic requirement that: a) Involves a feature or characteristic not required in the a
22、pplication of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.2 effective December 23, 2010 2.3 A component shall be used in accordance with its rating established for the intended conditions of use. 2.3 effective December 23, 2010 2.4
23、Specic components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding specied limits, and shall be used only under those specic conditions. 2.4 effective Dece
24、mber 23, 2010 DECEMBER 23, 2008 UL 448B 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 3 Units of Measurement 3.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 3.1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL448B2008ULSTANDARDFORSAFETYRESIDENTIALFIREPUMPSINTENDEDFORONEANDTWOFAMILYDWELLINGSANDMANUFACTUREDHOMESFIRSTEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUPDF

链接地址:http://www.mydoc123.com/p-1068167.html