《UL 444 CRD-2012 UL Standard for Safety Communications Cables - Section Paragraph Reference Pars 5 1 1 5 1 3 7 17 Tables 1 2 3 and 5 Subject Coaxial Cables - Copper Tube Center Con.pdf》由会员分享,可在线阅读,更多相关《UL 444 CRD-2012 UL Standard for Safety Communications Cables - Section Paragraph Reference Pars 5 1 1 5 1 3 7 17 Tables 1 2 3 and 5 Subject Coaxial Cables - Copper Tube Center Con.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): DUZXStandard Number: UL 444Edition Date: July 11, 2008Edition Number: 4Section / Paragraph Reference: Pars. 5.1.1, 5.1.3, 7.17 Tables 1, 2, 3, and 5Subject:
3、Coaxial Cables - Copper Tube Center ConductorDECISION:5.1.1 The conductors shall be solid or stranded, annealed, bare or metal-coated copper. The centreconductor of coaxial cables is also permitted to be a smooth or corrugated copper tube. The centreconductor of CMP, CMR, CMG, CM, CMH and CMX coaxia
4、l cables made of copper-clad steel shall have21 percent or higher conductivity in accordance with ASTM Standard B 869.5.1.3 If the insulation adjacent to the copper conductor is of a material that corrodes unprotected copperin the test described in Clause 7.1, the conductor shall be covered with a c
5、oating of tin complying withASTM Standard B 33, of lead or lead-alloy complying with ASTM Standard B 189, of nickel complying withASTM Standard B 355, of silver complying with ASTM Standard B 298, or of another metal or alloy.Evaluation of the effectiveness of these coatings shall be required. Metal
6、-coating a conductor on whichthe coating is not required for corrosion protection shall be permitted. When this is done, the 100 per centcoverage requirement of the relevant ASTM Standard shall be waived.The maximum temperature rating of cables relative to the diameter and coating of solid copper co
7、nductorsor copper conductor strands or the thickness and coating of tubular copper conductors shall not be higherthan those shown in Table 1.7.17 Conductor diameter or cross-sectional areaMeasurements of the diameter of a solid conductor or of a wire (strand) from a stranded conductor, thecross-sect
8、ional area of a stranded conductor, or the cross-sectional area of a tubular conductor shall bemade in accordance with the procedure outlined in the test, Conductor Diameter, Cross-sectional Area byMass (Weight) Method, or Cross-sectional Area by Diameter Method, in CSA C22.2 No. 2556 or UL 2556.UL
9、COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULTable 1Maximum temperature rating of cables relative to diameter and coating of the solid copperconductor or of each copper conductor strand or thickness and coating of the tubular copperconductor(S
10、ee Clause 5.1.3.)Diameter of each strand or of the solid conductor or thickness of thetubular conductorMetal coating Smaller than 0.38 mm (0.015 in) At least 0.38 mm (0.015 in)Uncoated, tin or tin/lead alloy coating 150C 200CSilver coating 200C 200CNickel coating over 200C over 200CTable 2Maximum di
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL444CRD2012ULSTANDARDFORSAFETYCOMMUNICATIONSCABLESSECTIONPARAGRAPHREFERENCEPARS511513717TABLES123AND5SUBJECTCOAXIALCABLESCOPPERTUBECENTERCONPDF

链接地址:http://www.mydoc123.com/p-1068159.html