TIA-526-14-A-1998 OFSTP-14 Optical Power Loss Measurements of Installed Multimode Fiber Cable Plant ANSI APPROVAL WITHDRAWN AUGUST 2003《OFSTP-14 多模光缆安装的光强度损失测量》.pdf
《TIA-526-14-A-1998 OFSTP-14 Optical Power Loss Measurements of Installed Multimode Fiber Cable Plant ANSI APPROVAL WITHDRAWN AUGUST 2003《OFSTP-14 多模光缆安装的光强度损失测量》.pdf》由会员分享,可在线阅读,更多相关《TIA-526-14-A-1998 OFSTP-14 Optical Power Loss Measurements of Installed Multimode Fiber Cable Plant ANSI APPROVAL WITHDRAWN AUGUST 2003《OFSTP-14 多模光缆安装的光强度损失测量》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、 TIA DOCUMENT OFSTP-14 Optical Power Loss Measurements of Installed Multimode Fiber Cable Plant TIA-526-14-A (Revision of EIA/TIA-526-14) ANSI APPROVAL WITHDRAWN AUGUST 2003 AUGUST 1998 TELECOMMUNICATIONS INDUSTRY ASSOCIATION The Telecommunications Industry Association represents the communications
2、sector of Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-NOTICE TIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunders
3、tandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for their particular need. The existence of such Publications shall not in any respect preclude any
4、 member or non-member of TIA from manufacturing or selling products not conforming to such Publications. Neither shall the existence of such Documents preclude their voluntary use by non-TIA members, either domestically or internationally. TIA DOCUMENTS TIA Documents contain information deemed to be
5、 of technical value to the industry, and are published at the request of the originating Committee without necessarily following the rigorous public review and resolution of comments which is a procedural part of the development of a American National Standard (ANS). Further details of the developme
6、nt process are available in the TIA Engineering Manual, located at http:/www.tiaonline.org/standards/sfg/engineering_manual.cfm TIA Documents shall be reviewed on a five year cycle by the formulating Committee and a decision made on whether to reaffirm, revise, withdraw, or proceed to develop an Ame
7、rican National Standard on this subject. Suggestions for revision should be directed to: Standards therefore, the user is responsible for determining whether the equipment temperature stability and optical power linearity is consistent with the accuracy and precision that is desired. NOTE: Non-linea
8、rity between the measured and incident optical power will introduce measurement error. Also, equipment with internal waveguides may exhibit measurement variability with varying modal conditions. 3.3 Test Jumpers The test jumper fibers shall have core diameter and numerical aperture nominally equal t
9、o those of the cable plant being measured. The jumpers shall be 1 to 5 meters (3.3 to 16.4 ft) long, and shall contain fibers with coatings that remove cladding light. Terminations shall be compatible with the light source and cable plant. 3.4 Miscellaneous Equipment To interface test jumpers with t
10、he cable plant, appropriate adapters may be required. Materials to clean the connections (such as reagent grade isopropyl alcohol, cotton swabs, and clean compressed air) may also be required. Equipment to inspect connectors for damage may be helpful. Copyright Telecommunications Industry Associatio
11、n Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-TIA-526-14-A 44. SAMPLING AND SPECIMENS The specifier shall describe, with appropriate documentation, which elements are to be measured. See Annex B. NOTE: Generally, the descript
12、ion will be one of the following cases: all cable segments, or a set of segments configured into point-to-point runs (through jumpers, patch panels, junction boxes, adapters, etc.). 5. PROCEDURE Measure the optical loss of the cable plant according to one of the following methods (For guidance in se
13、lecting a method, See Annex B): Method A - Two jumper reference (see 5.2) Method B - One jumper reference (see 5.3) Method C - Three jumper reference (see 5.4) 5.1 Precautions 5.1.1 To achieve consistent results, clean all connections and adapters at the optical test points prior to measurement. 5.1
14、.2 Unless otherwise specified in the Detail Specification, perform the following procedures at the wavelengths specified in 3.1.1. 5.1.3 Unless otherwise specified in the Detail Specification, perform the measurements bi-directionally. 5.1.4 All optical power measurements shall be recorded to one si
15、gnificant digit in the decimal place (e.g. -14.3 dBm, 10.1mW). 5.1.5 Reestablish the reference as necessary. Situations which might indicate a need to reestablish the reference include optical power changes, temperature fluctuations, a move to a different location, and jumper/adapter replacement due
16、 to degradation. 5.2 METHOD A: Two Jumper Reference 5.2.1 Connect test jumpers 1 and 2 between the light source and the optical power meter, as shown in Figure 1. Record the optical power, P1, which is the reference power measurement. Copyright Telecommunications Industry Association Provided by IHS
17、 under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-TIA-526-14-A 5TEST JUMPER 1LIGHTSOURCEOPTICAL POWEREQUIPMENTMEASUREMENTP1TEST JUMPER 2Figure 1. Reference Power Measurement for Method A 5.2.2 Separate the two jumpers at their point of connection
18、 without disturbing their attachment to the test equipment. Reattach test jumper 1 to one end of the cable plant to be measured, and test jumper 2 to the other end, as shown in Figure 2. TEST JUMPER 1 TEST JUMPER 2 LIGHT SOURCECABLE PLANT OPTICAL POWER EQUIPMENT MEASUREMENT 2 P Figure 2. Cable Plant
19、 Measurement for Methods A, B and C 5.2.3 Record the displayed optical power, P2, which is the test power measurement. 5.3 METHOD B: One Jumper Reference 5.3.1 Connect test jumper 1 between the light source and the optical power meter, as shown in Figure 3. Record the displayed optical power, P1, wh
20、ich is the reference power measurement. Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-TIA-526-14-A 6TEST JUMPER 1LIGHTSOURCEOPTICAL POWEREQUIPMENTMEASUREMENTP1Figure 3. Referenc
21、e Power Measurement for Method B 5.3.2 Disconnect test jumper 1 from the optical power meter without disturbing the connection to the light source, and attach it to the cable plant input. 5.3.3 Attach test jumper 2 to the output (far) end of the cable plant, and to the power meter, as shown in Figur
22、e 2. 5.3.4 Record the displayed optical power, P2, which is the test power measurement. 5.4 METHOD C: Three Jumper Reference 5.4.1 Connect test jumpers 1, 2, and 3 between the light source and the optical power meter, as shown in Figure 4. Record the displayed optical power, P1, which is the referen
23、ce power measurement. P TEST JUMPER 1 TEST JUMPER 2 LIGHT SOURCETESTOPTICAL POWER EQUIPMENT MEASUREMENT 1 JUMPER 3Figure 4. Reference Power Measurement for Method C 5.4.2 Disconnect separate test jumper 3 without removing the adapters from test jumpers 1 and 2 at their point of connection. Do not di
24、sturb the test jumpers at their attachment to the test equipment. 5.4.3 Attach test jumper 1 to the cable plant input and test jumper 2 to the output (far) end of the cable plant as shown in Figure 2. Test jumper 3 is not used in the test power measurement. 5.4.4 Record the displayed optical power,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- TIA52614A1998OFSTP14OPTICALPOWERLOSSMEASUREMENTSOFINSTALLEDMULTIMODEFIBERCABLEPLANTANSIAPPROVALWITHDRAWNAUGUST2003OFSTP14

链接地址:http://www.mydoc123.com/p-1060629.html