1、SSPC-Paint 23November 1, 1982Editorial Revisions November 1, 200469SSPC: The Society for Protective CoatingsPAINT SPECIFICATION NO. 23Latex Primer for Steel Surfaces1. Scope1.1 This specifi cation covers an air drying, ready-mixed, water-borne primer for blast cleaned steel. It is intended for use a
2、s a primer coat of a water-borne coating system consisting of two coats of this primer and one or two coats of a water-borne topcoat.1.2 This primer is suitable for exposures in Environmental Zones 1A (interior, normally dry) and 1B (exterior, normally dry), and is intended for brush, spray, or roll
3、er application over steel surfaces prepared in accordance with SSPC-SP 6, “Commercial Blast Cleaning.” It is suitable as a shop primer, fi eld primer, maintenance primer, or intermediate coat and is to be applied in accordance with SSPC-PA 1, “Shop, Field, and Maintenance Painting of Steel.” It is n
4、ot recommended to expose steel to the weather with less than two coats of water-borne coating; therefore, intermediate and topcoats should be applied as soon as possible.2. Description2.1 This primer is based on a latex vehicle produced by emulsion polymerization and appropriate pigments. Details of
5、 the composition are given in Table 1.2.2 This primer contains approximately 36% by volume of nonvolatile fi lm-forming solids (pigment and binder). The theoretical spreading rate for a 2.0 mil (51 micrometers) dry fi lm thickness is 290 square feet/U.S. gallon (7.1 square meters/liter). Actual spre
6、ading rates can be signifi cantly lower.3. Referenced Standards3.1 The latest issue, revision, or amendment of the refer-enced standards in effect on the date of invitation to bid shall govern, unless otherwise specifi ed. 3.2 If there is a confl ict between the requirements of any of the cited refe
7、renced standards and this specifi cation, the requirements of this specifi cation shall prevail.3.3 SSPC STANDARDS AND JOINT STANDARDS:SSPC Guide 13 Guide for the Identifi cation and Use of Industrial Coating Material in Computerized Product DatabasesPA 1 Shop, Field, and Maintenance Painting of Ste
8、elPaint 24 Latex Semigloss Exterior Top-coatSP 6/NACE No. 3 Commercial Blast CleaningVIS 2 Guide and Reference Photographs for Evaluating the Degree of Rust-ing on Steel Surfaces3.4 ASTM INTERNATIONAL STANDARDS:B 117 Method of Salt Spray (Fog) TestingD 522 Test Methods for Mandrel Bend Test of Attac
9、hed Organic CoatingsD 523 Test Method for Specular GlossD 562 Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer-type ViscometerD 609 Practice for Preparation of Cold-Rolled Steel Panels for Testing Paint, Varnish,Conversion Coatings, and Related Coating Produc
10、tsD 610 Test Method for Evaluating Degree of Rust-ing on Painted Steel SurfacesD 714 Test Method for Evaluating Degree of Blistering of PaintsD 1210 Test Methods for Fineness of Dispersion of Pigment-Vehicle Systems by Hegman-type GageD 1296 Test Method for Odor of Volatile Solvents and DiluentsD 16
11、40 Test Methods for Drying, Curing, or Film Formation of Organic Coatings at Room TemperatureD 1654 Method for Evaluation of Painted or Coated Specimens Subjected to Corrosive Environ-mentsD 1737 (Canceled) Elongation of Attached Organic Coatings with Cylindrical Mandrel Apparatus (Replaced with AST
12、M D522)D 1849 Test Method for Package Stability of PaintD 2243 Test Method for Freeze-Thaw Resistance of Water-Borne CoatingsD 2247 Practice for Testing Water Resistance of Coatings in 100% Relative HumidityD 2486 Test Method for Scrub Resistance of Wall PaintsD 2574 Test Method for Resistance of Em
13、ulsion Paints in the Container to Attack by Micro-organismsSSPC-Paint 23November 1, 1982Editorial Revisions November 1, 200470D 2801 (Withdrawn) Test Method for Leveling Char-acteristics of Paints by Draw-Down Method (See ASTM D 4400.)D 3273 Test Method for Resistance to Growth of Mold on the Surfac
14、e of Interior Coatings in an Environmental ChamberD 3274 Test Method for Evaluating Degree of Surface Disfi gurement of Paint Films by Microbial (Fungal or Algal) Growth or Soil and Dirt AccumulationD 3891 Standard Practice for Preparation of Glass Panels for Testing Paint, Varnish, Lacquer, and Rel
15、ated ProductsD 3925 Practice for Sampling Liquid Paints and Related Pigmented CoatingsD 4400 Test Method for Sag Resistance of Paints Using a Multinotch Applicator3.5 FEDERAL STANDARDS:TT-E-506 Enamel, Alkyd, Gloss, Tints and White (for Interior Use)FED-STD-141 Paint, Varnish, Lacquer and Related Ma
16、terials: Methods of Inspection, Sampling and Testing Method 2021 (Canceled) Preparation of Glass Panels (Use ASTM D 3891)Method 6141.1 (Canceled) Washability3.6 AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) STANDARD:Z129.1 Hazardous Industrial ChemicalsPrecautionary Labeling4. Composition4.1 The manu
17、facturer is given some latitude in the selec-tion of materials and process of manufacture, provided that the primer meets the requirements of this specifi cation. Materials shall be of the best quality used in good commercial practice and entirely suitable for the purpose intended under normal condi
18、tions of use.4.2 The vehicle shall be a stable dispersion of synthetic resin particles (latex) in water prepared by emulsion polymer-ization, together with the necessary additives such as pigment dispersant, antifoamer, preservatives, and “antifreeze” in order to produce a primer conforming to this
19、specifi cation. A suitable fi lm and package preservative shall be used.4.3 The paint shall conform to the composition (analysis) requirements of Table 1.5. Properties5.1 The paint shall meet the requirements of Table 2 and Sections 5.2 through 5.17.5.2 ODOR: Shall be normal for the materials permit
20、ted (ASTM D 1296). In a freshly opened container, there shall be no offensive, disagreeable, or putrid odor.5.3 COLOR: The color shall be as specifi ed in the procure-ment documents.5.4 RESISTANCE TO MICROORGANISM ATTACK: The paint shall be resistant to attack by microorganisms when tested according
21、 to ASTM D 2574.5.5 APPLICATION PROPERTIES: The paint shall be easily applied to a smooth steel vertical surface at 4 mils (102 micrometers) wet fi lm thickness on 400 square feet/gallon (9.8 square meters/liter) by brush, spray, or roller. Drying shall be done in a well-ventilated room or chamber f
22、ree from drafts and dust in diffused light, not in direct sunlight. The temperature of the air shall be between 21 and 28C. The relative humidity shall be 50% 5%. There shall be no runs, sags, streaks, fl ashes, laps, pinholing, eyeing, or cratering. After four hours of drying, apply a second coat i
23、n the same manner as the fi rst. There shall be no picking-up or rolling-up of the fi rst coat during applications. After 24 hours, the fi lm shall be smooth and uniform.5.6 CONDITION IN CONTAINER: The primer as received shall show no evidence of livering, skinning, or hard settling of the pigment.
24、The inside of the container shall not be corroded. The material shall be easily dispersed in the liquid portion by hand stirring to form a smooth homogeneous paint. The primer shall show a minimum of foaming and be free of grit, seeds, lumps, or livering.5.7 FREEZE-THAW RESISTANCE: The paint shall p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SSPCPAINT231982LATEXPRIMERFORSTEELSURFACES 钢结构 乳胶 底漆 编辑 变更 2004 11 PDF

链接地址:http://www.mydoc123.com/p-1054464.html