SMPTE RP 113-1996 Supervisory Protocol for Digital Control Interface.pdf
《SMPTE RP 113-1996 Supervisory Protocol for Digital Control Interface.pdf》由会员分享,可在线阅读,更多相关《SMPTE RP 113-1996 Supervisory Protocol for Digital Control Interface.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、STD-SMPTE RP LLL3-ENGL 197b 8357403 0002bb7 b73 SMPTE RECOMMENDED PRACTICE Supervisory Protocol for Digital Control Interface RP 11 3-1 996 Revision of RP 1 13-1 992 Page 1 of 9 pages 1 General 1.1 Scope This practice defines the supervisory protocol used within a general purpose communication chann
2、el of an interface system which transports data and digital control signals between equipment utilized in the pro- duction, post-production, and/or transmission of visual and aural information. It is intended that the supervisory protocol described in this practice be part of an overall system, allo
3、wing interconnection of pro- grammable and nonprogrammable equipment as re- quired to configure an operational system with a defined function, and to allow rapid reconfiguration of a system to provide more than one defined function utilizing a given group of equipment. 1.1.1 The primary intent of th
4、is practice is to establish supervisory procedures of the commu- nication channel for the purpose of transmitting control messages to equipment by external means. (The contents of the messages are not defined.) This practice, or sections thereof, may be applied to the interconnection of elements wit
5、hin an item of equipment. 1.2 Definitions (See figure 1 .) For the purposes of this practice, the following definitions apply: 1.2.1 bus controller: Each system contains one bus controller which supervises all tributaries in the system. Supervision is exercised through the use of this supervisory pr
6、otocol. 1.2.2 byte: A byte consists of eight bits of infor- mation. Bits used to effect transmission such as byte start, parity, or end are not part of the byte. 1.2.3 tributary: A tributary transfers messages to and from an operational device via the inter- face system. The tributary is distinct fr
7、om the function of the operational device and exists to transfer control messages between the commu- nication channel and the device. 1.2.4 word: A word consists of a byte and asso- ciated bits used to effect transmission such as start, parity, or end. 2 Message types Two types of messages shall be
8、transmitted on the channel: Supervisory messages to supervice the channel and direct the flow of device messages. Device messages to control operation of equipment functions. This type of message shall be transmitted only within standard message blocks or during device defined communications modes.
9、Details of device messages are specified in RP 138. 3 Tributary addresses Tributary addresses shall consist of two bytes: the most significant byte, which is transmitted first, and the least significant byte. The most significant bit of both bytes shall be set to binary 1. This provides an address r
10、ange starting at 8080h. Each tributary shall be assigned two unique addresses, a SELECT address and a POLL address. 3.1 Select address An address in which the least significant bit of the least significant byte equals binary O is a SELECT address. Copyright Q 1996 by the SOCIETY OF MOTION PICTURE AN
11、D TELEVISION ENGINEERS 595 W. Hartsdale Ave., White Plains, NY 10607 (914) 761-1 100 Approved December 10,1996 RP 113-1996 BUS CONTROLLER r- -1 HIGHER LEVELS I I-l DATA BYTE FLAG t corT t SUPERVISORY PROTOCOL 3.2 Poll address EQUIPMENT TRI BUTA RY HIGHERLEVELS -i L -_I DATA BYTE FLAG P ROTO CO L MEC
12、HANICAL I Figure 1 - System elements An address in which the least significant bit of the least significant byte equals binary 1 is a POLL address. 3.3 Group addresses Address pairs 8080-8081 h and 8082-80831, through 81FE-81FFh are reserved as GROUP SELECT ad- dresses. The addresses in which the le
13、ast significant bit of the least significant byte equals binary 1 (POLL address) shall not be used but are retained in the address numbering scheme for software considera- tions. 3.4 Discrete addresses 3.5 Address allocation table 8080-8081 h 8082-8OFFh 8180-81 FFh 8280-82FFh 64 tributaries 8380-83F
14、Fh 64 tributaries Group select - all call Group select - groups 1-63 Group select - groups 64-127 e FFSO-FFFFh 64 tributaries 4 Tributary operational states A tributary shall be in one of five major operational states: Tributary addresses shall start at 8280-8281 h. Pre- cisely 8064 discrete tributa
15、ry address pairs are avail- able. BREAK. IDLE: The tributary shall not perform any communi- cations. This state shall be exited only in response to Page 2 of 9 pages STDmSNPTE RP LL3-ENGL L77b m 8357403 0002bb9 444 m RP 113-1996 ACTIVE: Prerequisite for transition to other opera- All other superviso
16、ry characters are reserved. The tional states. The tributary shall enter this state when- use of other characters for tributary supervision is ever BREAK is received. noncompliant with this specification. POLL: The tributaryshall transmit asingle status byte to the bus controller. SELECT A single tr
17、ibutary shall enter a communica- tions mode with the bus controller. GROUP SELECT All tributaries or a selected group of tributaries shall enter a communcaton ,ode with the bus controller. 6 Operational sequences (See figure 2) 6.1 Idle Tributaries in the idle state shall not perform any communicati
18、ons sequences. 6.7.7 Idle shall be entered under the following condi- tions: - Tributary power on or reset; - Upon receipt of an (ADDR-SEL) not assigned to the tributary; - Upon receipt of a GROUP (ADDR-SEL) not assigned to the tributary; 5 Supervisory messages Tributaries shall be directed to opera
19、tional states through various communications sequences by supervisory messages as shown in figure 2. Super- visory messages consist of the following elements: BREAK: Shall drive all tributaries to the ACTIVE state. (See ANSVSMPTE 207M for code.) - When a specified time out of six words in duration o
20、ccurs; - On receipt of an undefined byte; - On encountering a transmission error or ambigu- ous condition. (ADDR-POLL): A tributary poll address (ADDR- POLL) shall drive the addressed tributary to the POLL state. (ADDR-SELECT): A tributaryse1ect address (ADDR- 6-1.2 A tributary shall exit the IDLE s
21、tate only on SEL) shall drive the addressed tributary to the SELECT state. receipt of BREAK. 6.2 Active (GROUP ADDR-SEL): A group select address shall Supervisory character: Identify communications sequences and provide status information. Supervisory characters are single bytes within the range OOh
22、-7Fh. Supervisory characters shall consist of: 01h 02 03 04 05 06 07 08 o9 Group assign Start of message Escape Acknowledge Not acknowledge Busy Reset Service request from tributary Transmit enable 6.2.1 All tributaries shall enter the ACTIVE state whenever BREAK is received and on completion of a p
23、oll sequence. 6.2.2 A tributary shall exit the ACTIVE state on receipt of an address which directs it to the POLL, SELECT, or GROUP SELECT states. A time out between the two address bytes shall cause the tributary to enter the IDLE state. 6.3 Poil The POLL state shall be used to determine the pres-
24、ence and status of a tributary. Page 3 of 9 pages RP 113-1996 STD*SMPTE RP LLI-ENGL L77b M 8357403 0002b70 Lbb W 3 O w r c i Page 4 of 9 pages STDBSMPTE RP LL3-ENGL 379b = 8357403 0002b7L UT2 6.3.1 A tributary shall enter the POLL state on receipt of its poll address (ADDR-POLL). The tributary shall
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SMPTERP1131996SUPERVISORYPROTOCOLFORDIGITALCONTROLINTERFACEPDF

链接地址:http://www.mydoc123.com/p-1046354.html