1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-18815-3 SANS 61378-3:2007Edition 1IEC 61378-3:2006Edition 1SOUTH AFRICAN NATIONAL STANDARD Converter transformers Part 3: Application guid
4、e This national standard is the identical implementation of IEC 61378-3:2006 and is adopted with the permission of the International Electrotechnical Commission. Published by Standards South Africa 1 dr lategan road groenkloof private bag x191 pretoria 0001 tel: 012 428 7911 fax: 012 344 1568 intern
5、ational code + 27 12 www.stansa.co.za Standards South Africa SANS 61378-3:2007 Edition 1 IEC 61378-3:2006 Edition 1 Table of changes Change No. Date Scope National foreword This South African standard was approved by National Committee StanSA TC 69, Power electronics and alternative energy conversio
6、n, in accordance with procedures of Standards South Africa, in compliance with annex 3 of the WTO/TBT agreement. This part of SANS 61378 was published in February 2007 . NORME INTERNATIONALECEIIECINTERNATIONAL STANDARD 61378-3Premire ditionFirst edition2006-04Transformateurs de conversion Partie 3:
7、Guide dapplication Converter transformers Part 3: Application guide Pour prix, voir catalogue en vigueur For price, see current catalogue IEC 2006 Droits de reproduction rservs Copyright - all rights reserved Aucune partie de cette publication ne peut tre reproduite ni utilise sous quelque forme que
8、 ce soit et par aucun procd, lectronique ou mcanique, y compris la photocopie et les microfilms, sans laccord crit de lditeur. No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in
9、writing from the publisher. International Electrotechnical Commission, 3, rue de Varemb, PO Box 131, CH-1211 Geneva 20, SwitzerlandTelephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmailiec.ch Web: www.iec.ch CODE PRIX PRICE CODE XC Commission Electrotechnique InternationaleInternationa
10、l Electrotechnical Commission SANS 61378-3:2007This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS .61378-3 IEC:2006 3 CONTENTS FOREWORD.7 INTRODUCTION.11 1 Scope.17 2 Normative references .17 3 Terms and definitions .19 4 Symbols and abbreviation
11、s.19 5 Rating data.21 6 Winding configurations .21 6.1 General .21 6.2 Industrial applications25 6.3 HVDC applications 33 7 Tappings and impedances HVDC applications.39 7.1 Value of impedance.39 7.2 Variability of impedance 39 8 Insulation aspects and dielectric tests 41 8.1 Hybrid insulation system
12、s41 8.2 Dielectric tests 45 9 Losses53 9.1 General .53 9.2 Thermal tests 75 10 Core and sound aspects.77 10.1 Core77 10.2 Sound .79 11 Transformer specification .83 11.1 General .83 11.2 Technical specification versus functional specifications.85 11.3 HVDC transformer specifications.85 11.4 Notes an
13、d comments on specification items to be provided individually by purchaser and supplier87 11.5 Information to be provided by the supplier .87 11.6 Quality assurance and test programme .95 11.7 Availability and measures to minimize service downtime .95 11.8 Information to be provided by the purchaser
14、 or by the system designer.95 12 Short circuit considerations 113 13 Components .121 13.1 On-load tap-changers121 13.2 Valve-side bushings 123 14 Maintenance.131 14.1 General .131 14.2 Oil .133 14.3 Insulation quality .135 14.4 Tap-changers 145 14.5 Accessories and fittings.147 SANS 61378-3:2007This
15、 s tandard may only be used and printed by approved subscription and freemailing clients of the SABS .61378-3 IEC:2006 5 15 Monitoring 149 15.1 General .149 15.2 Transformer condition assessment in service 149 15.3 Types of monitor .151 15.4 Summary.159 Bibliography161 Figure 1 Bridge connection for
16、 six-pulse arrangement23 Figure 2 Bridge connection for twelve-pulse arrangement 23 Figure 3 Transformer connections star-delta and star-star or alternatively, delta-delta and delta-star to give a 30 electrical degree separation between the valve-side voltages23 Figure 4 15 phase shifting is prefera
17、bly realized by extended delta or zigzag connection. .25 Figure 5 Connection of self-saturated reactors.27 Figure 6 Autotransformer concept for open phases 29 Figure 7 Conventional autotransformer concept for closed phases with coarse and fine regulation for small regulating steps.29 Figure 8 Booste
18、r arrangement for autotransformer concept for closed phases with coarse and fine regulation for small regulating steps.31 Figure 9 Delta connection with tapped windings.31 Figure 10 Two winding design with tapped winding 33 Figure 11 Two basic arrangements of the individual windings of a two-winding
19、 transformer .35 Figure 12 Mutual impedance39 Figure 13 Typical impedance pattern .41 Figure 14 Components of a typical industrial converter transformer insulating system43 Figure 15 Insulation system, equivalent R-C circuit47 Figure 16 Voltage distribution before and immediately after polarity reve
20、rsal .49 Figure 17 AC/DC conversion Simplified sketch51 Figure 18 Leakage fields for a three-winding transformer with closely coupled valve windings .63 Figure 19 Leakage fields for a three-winding transformer with decoupled valve windings .65 Figure 20 Leakage fields for a three winding transformer
21、 with loosely coupled double concentric valve windings .67 Figure 21 Leakage fields for a three winding transformer with loosely coupled double-tier valve windings.69 Figure 22 Short-circuit fault conditions .115 Figure 23 Arrangement of valve bushings 127 Figure 24 Examples of a.c., d.c. and combin
22、ed electric field dispositions adjacent to HVDC bushings and associated electric insulation systems 129 Table 1 Arrangements of two windings.35 SANS 61378-3:2007This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS .61378-3 IEC:2006 7 INTERNATIONAL
23、ELECTROTECHNICAL COMMISSION _ CONVERTER TRANSFORMERS Part 3: Application guide FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promot
24、e international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (h
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS6137832007CONVERTERTRANSFORMERSPART3APPLICATIONGUIDE 换流 变压器 部分 应用 指南 PDF

链接地址:http://www.mydoc123.com/p-1031597.html