SANS 60839-2-5-2010 Alarm systems Part 2 Requirements for intruder alarm systems Section 5 Microwave Doppler detectors for use in buildings《警报系统 第2部分 闯入者报警系统的要求 第5节 建筑物内使用的微波多普勒探测器.pdf
《SANS 60839-2-5-2010 Alarm systems Part 2 Requirements for intruder alarm systems Section 5 Microwave Doppler detectors for use in buildings《警报系统 第2部分 闯入者报警系统的要求 第5节 建筑物内使用的微波多普勒探测器.pdf》由会员分享,可在线阅读,更多相关《SANS 60839-2-5-2010 Alarm systems Part 2 Requirements for intruder alarm systems Section 5 Microwave Doppler detectors for use in buildings《警报系统 第2部分 闯入者报警系统的要求 第5节 建筑物内使用的微波多普勒探测器.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-24132-2 SANS 60839-2-5:2010Edition 1IEC 60839-2-5:1990Edition 1SOUTH AFRICAN NATIONAL STANDARD Alarm systems Part 2: Requirements for intr
4、uder alarm systems Section 5 Microwave Doppler detectors for use in buildings This national standard is the identical implementation of IEC 60839-2-5:1990 and is adopted with the permission of the International Electrotechnical Commission. WARNING Can only be used in conjunction with SANS 60839-1-1
5、and SANS 60839-2-2. Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001Tel: +27 12 428 7911 Fax: +27 12 344 1568 www.sabs.co.za SABS SANS 60839-2-5:2010 Edition 1 IEC 60839-2-5:1990 Edition 1 Table of changes Change No. Date Scope National foreword This S
6、outh African standard was approved by National Committee SABS TC 68, Electrical and electronic security systems, in accordance with procedures of the SABS Standards Division, in compliance with annex 3 of the WTO/TBT agreement. This SANS document was published in March 2010. NORMEINTERNATIONALEINTER
7、NATIONALSTANDARDSystemes dalarmeCEIIEC60839-2-5Premiere editionFirst edition1990-07Partie 2:Prescriptions pour les systemes dalarmeanti-intrusionSection 5 - Detecteurs hyperfrequence aeffetDoppler-Fizeau utilises dans les batimentsAlarm systemsPart 2:Requirements for intruder alarm systemsSection 5
8、- Microwave Doppler detectorsfor use in buildings IEC 1990 Oroits de reproduction reserves - Copyright - all rights reservedAucune partie de celte pUblication ne peut etre reproduite niutilisee sous quelque forme que ce soit et par aucunprocede, electronique ou mecanique, y compris la photo copie et
9、 les microfilms, sans Iaccord ecrit de Iediteur.No part of this publication may be reproduced or utilized inany form or by any means, electronic or mechanical,including photocopying and microfilm, without permission inwriting from the publisher.International Electrotechnical Commission 3, rue de Var
10、embe Geneva, SwitzerlandTelefax: +41 229190300 e-mail: inmailiec.ch IEC web site http: Ilwww.iec.chPour prix, voir catalogue en vigueurFor price, see current catalogueIICommission Electrotechnique InternationaleInternational Electrotechnical Commission:M:e:K:IJ.Y:H:a:po:IJ.:H:a:A:3:ne:K:TP:o:T:ex:H:
11、I-I.:e:c:Ka:A:K:o:M:I-I:C:CI-I;CODE PRIXPRICE CODEKSANS 60839-2-5:2010This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS .839-2-5 IEC - 3 -CONTENTSPageFOREWORD. 5PREFACE. 5Clause1.2.3.4.5.6.ScopeNormative references .DefinitionsGeneral considerat
12、ions .Requirements .Test p rocedures .77991115SANS 60839-2-5:2010This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS .839-2-5 IEC - 5 -INTERNATIONAL ELECTROTECHNICAL COMMISSIONALARM SYSTEMSPart 2: Requirements for intruder alarm systemsSection 5 -
13、 Microwave Doppler detectors foruse in buildingsFOREWORD1) The formal decisions or agreements of the IEC on technical matters,prepared by Technical Committees on which all the National Committeeshaving a special interest therein are represented, express, as nearlyas possible, an international consen
14、sus of opinion on the subjectsdealt with.2) They have the form of recommendations for international use and theyare accepted by the National Committees in that sense.3) In order to promote international unification, the IEC expresses thewish that all National Committees should adopt the text of the
15、IECrecommendation for their national rules in so far as national condi tions will permit. Any divergence between the IEC recommendation andthe corresponding national rules should, as far as possible, be clearlyindicated in the latter.PREFACEThis standard has been prepared by IEC Technical Committee
16、No. 79:Alarm systems.The text of this standard is based upon the following documents:Six Months Rule Report on Voting79(CO)26 79(CO)36Full information on the voting for the approval of this standard can befound in the Voting Report indicated in the above table.SANS 60839-2-5:2010This s tandard may o
17、nly be used and printed by approved subscription and freemailing clients of the SABS .839-2-5 IEC - 7 -ALARM SYSTEMSPart 2: Requirements for intruder alarm systemsSection 5 - Microwave Doppler detectors foruse in buildings1. ScopeThis International Standard gives the specific requi rements and testp
18、rocedures for microwave Doppler detectors for use in intruder alarmsystems installed in buildings.This standard is an addition to the general requirements for detec tors for use in intruder alarm systems as specified in IEC Publi cation 839-2-2, and it shall also be used in conjunction with thestand
19、ard for general requirements for alarm systems, IEC Publica tion 839-1-1.The object of this standard is to specify those requirements formicrowave Doppler detectors which will ensure that they will performsatisfactorily and minimize false alarms.2. Normative referencesThe following standards contain
20、 provIsions which, th rough referencein this text, constitute provisions of this Internatinal Standard. At thetime of publication, the editions indicated were valid. All standards aresubject to revision, and parties to agreements based on this Inter national Standard are encouraged to investigate th
21、e possibility ofapplying the most recent editions of the standards indicated below.Members of IEC and ISO maintain registers of currently valid Inter national Standards.IEC Publications:68-1 (1988): Environmental testing, Part 1: General and guidance.839-1-1 (1988): Alarm systems, Part 1: General re
22、quirements. SectionOne - General.839-1-3 (1988): Section Three - Environmental testing.839-2-2 (1987): Part 2: Requirements for intruder alarm systems.Section Two - Requi rements for detectors - General.SANS 60839-2-5:2010This s tandard may only be used and printed by approved subscription and freem
23、ailing clients of the SABS .839-2-5 IEC3. Definitions- 9 -For the pu rpose of this standard the following definitions apply inaddition to those given in the general requi rements.3. 1 Microwave Doppler detectorA detector which generates an alarm condition in response to thefrequency shift of the ref
24、lection of microwave radiation from a movingperson.3.2 SensorThe transmitting and receiving elements of the detector.3.3 Microwave radiationElectromagnetic radiation with a frequency above 1 GHz.3.4 Reference targetA person weighing between 50 kg and 70 kg and between 165 cm and180 cm in height, wea
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS60839252010ALARMSYSTEMSPART2REQUIREMENTSFORINTRUDERALARMSYSTEMSSECTION5MICROWAVEDOPPLERDETECTORSFORUSEINBUILDINGS

链接地址:http://www.mydoc123.com/p-1031434.html