SANS 50054-4-1997 Fire detection and fire alarm systems Part 4 Power supply equipment《火灾探测及火警系统 第4部分 电源设备》.pdf
《SANS 50054-4-1997 Fire detection and fire alarm systems Part 4 Power supply equipment《火灾探测及火警系统 第4部分 电源设备》.pdf》由会员分享,可在线阅读,更多相关《SANS 50054-4-1997 Fire detection and fire alarm systems Part 4 Power supply equipment《火灾探测及火警系统 第4部分 电源设备》.pdf(48页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ICS 13.220.20; 13.320 ISBN 0-626-14859-6 SANS 50054-4:1997 Edition 1 and EN corr. 1, EN amdt 1 EN 54-4:1997/AC:1999 Edition 1 and corr. 1, amdt 1 Any ref
4、erence to SABS EN 54-4, is deemed to be a reference to this standard (Government Notice No.1373 of November 2002) SOUTH AFRICAN NATIONAL STANDARD Fire detection and fire alarm systems Part 4: Power supply equipment This national standard is the identical implementation of EN 54-4:1997/AC:1999 includ
5、ing corrigendum 1 and amendment 1, and is adopted with the permission of CEN, rue de Stassart 36, B 1050 Brussels. Published by Standards South Africa 1 dr lategan road groenkloof ! private bag x191 pretoria 0001 tel: 012 428 7911 fax: 012 344 1568 international code + 27 12 www.stansa.co.za Standar
6、ds South Africa 2003 SANS 50054-4:1997 Edition 1 and EN corr.1, EN amdt 1 EN 54-4:1997/AC:1999 Edition 1 and corr.1, amdt1 Table of changes Change No. Date Scope EN corr. 1 1999 To change the reference EN 52-2 to EN 54-2. EN amdt 1 2002 To delete annex A and to add an informative Annex ZA which esta
7、blishes the conditions for the CE marking for fire safety of power supply equipment for fire detection and fire alarm systems for buildings and a bibliography. Abstract Specifies requirements, methods of test and performance criteria for power supply equipment of fire detection and fire alarm system
8、s installed in buildings. Keywords alarm systems, alarm systems in buildings, buildings, fire alarms, power supplier, specifications, testing. National foreword This South African standard was approved by National Committee STANSA TC 68, Security systems, in accordance with procedures of Standards S
9、outh Africa, in compliance with annex 3 of WTO/TBT agreement. EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 54-4:1997/ACFebruary 1999Fvrier 1999Februar 1999English versionVersion FranaiseDeutsche FassungFire detection and fire alarm systems - Part 4: Power supply equipmentSystmes de dtection et
10、dalarme incendie- Partie 4: Equipement dalimentationlectriqueBrandmeldeanlagen - Teil 4:EnergieversorgungseinrichtungenThis corrigendum becomes effective on 25 February 1999 for incorporation in the official Englishversion of the EN.Ce corrigendum prendra effet le 25 fvrier 1999 pour incorporation d
11、ans la version anglaise officiellede lEN.Die Berichtigung tritt am 25.Februar 1999 zur Einarbeitung die offizielle Englische Fassung der EN inKraft.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGCentral Secretariat: rue de Stassart, 36 B-1050 Brusse
12、ls 1999 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members.Tous droits dexploitation sous quelque forme et de quelque manire que ce soit rservs dans le monde entier auxmembres nationaux du CEN.Alle Rechte der Verwertung, gleich in welcher Form und
13、 in welchem Verfahren, sind weltweit den nationalen Mitgliedernvon CEN vorbehalten.Ref. No. EN 54-4:1997/AC:1999 EPage 2EN 54-4:1997/AC:1999ContentsPageForeword 4Introduction 51Scope 62 Normative references 63 Definitions and abbreviations 73.1 Definitions 73.2 Abbreviations 74 General requirements
14、84.1 Compliance 84.2 Power sources 85 Functions 95.1 Power supply from the main power source 95.2 Power supply from the standby power source (battery) 95.3 Charger 105.4 Faults 106 Materials, design and manufacture 116.1 Manufacturers declaration 116.2 Mechanical design 116.3 Electrical design 126.4
15、 Power supply interface 127 Documentation 137.1 Users documentation 137.2 Design documentation 148 Marking 149Test 159.1 General 159.2 Functional tests 159.3 Test of the charger and the standby power source 189.4 Environmental tests 199.5 Cold (operational) 219.6 Damp heat, steady state (operational
16、) 229.7 Impact (operational) 239.8 Vibration, sinusoidal (operational) 249.9 Electrostatic discharges (operational) 259.10 Radiated electromagnetic interference (operational) 27Page 3EN 54-4:1997/AC:19999.11 Voltage transients - fast transient bursts (operational) 289.12 Voltage transients - slow hi
17、gh energy transients (operational) 299.13 Mains voltage dips and interruptions (operational) 329.14 Damp heat, steady state (endurance) 339.15 Vibration, sinusoidal (endurance) 34Annex A (normative) Special national condition 35Page 4EN 54-4:1997/AC:1999ForewordThis European Standard has been prepar
18、ed by Technical Committee CEN/TC 72 “ Fire detectionand fire alarm systems”, the Secretariat of which is held by BSI.This standard has been prepared in co-operation with the CEA (Comit Europ en des Assurances)and with EURALARM (Association of European Manufacturers of Fire and Intruder AlarmSystems)
19、.EN 54 is published in a series of parts. Information on the relationship between this EuropeanStandard and other standards of the EN 54 series is given in annex A of EN 54-1. This European Standard shall be given the status of a national standard, either by publication of anidentical text or by end
20、orsement, at the latest by April 1998, and conflicting national standardsshall be withdrawn at the latest by April 1999. In addition, a further 36 months shall be allowed forcertification purposes for equipment conforming to the national standard.According to the CEN/CENELEC Internal Regulations, th
21、e national standards organizations of thefollowing countries are bound to implement this European Standard: Austria, Belgium, CzechRepublic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg,Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom
22、.Page 5EN 54-4:1997/AC:1999IntroductionThis European Standard is drafted on the basis of functions which are to be provided on all powersupply equipments. The power supply equipment may have its own cabinet, or may be housed withother equipment of the fire detection and fire alarm system, such as th
23、e control and indicatingequipment of EN 54-2. A fire detection and fire alarm system may use more than one powersupply equipment.Page 6EN 54-4:1997/AC:19991 ScopeThis European Standard specifies requirements, methods of test and performance criteria forpower supply equipment (see component L of figu
24、re 1 of EN 54-1) of fire detection and fire alarmsystems installed in buildings.NOTE: Power supply equipment with special characteristics, developed for particularapplications, is not necessarily the subject of this standard and may require further tests.2 Normative referencesThis European Standard
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS5005441997FIREDETECTIONANDFIREALARMSYSTEMSPART4POWERSUPPLYEQUIPMENT 火灾 探测 火警 系统 部分 电源 设备 PDF

链接地址:http://www.mydoc123.com/p-1030586.html