1、 SURFACE VEHICLE STANDARD J2970 MAR2015 Issued 2012-07 Revised 2015-03 Superseding J2970 JUL2012 Minimum Performance Requirements for Non-Refrigerant Tracer Gasses and Electronic Tracer Gas Leak Detectors RATIONALE This standard is being updated to modify the requirements when the tracer gas is sign
2、ificantly lighter than air. The Contaminated Atmosphere test is not required for tracer gases with a molecular weight of 20 or lower. Tracer gases with a molecular weight of 20 or lower will diffuse rapidly into the ambient atmosphere and will therefore not be a contaminant. 1. SCOPE This standard p
3、rovides the testing and functional requirements guidance necessary for a leak detection device that uses any non-A/C refrigerant tracer gas, such as helium or a nitrogen-hydrogen blend, to provide functional performance equivalent to a refrigerant electronic leak detector. It explains how a non- ref
4、rigerant leak detectors calibration can be established to provide levels of detection equal to electronic leak detectors that meet SAE J2791 for R-134a and SAE J2913 for R-1234yf. 2. REFERENCES 2.1 Applicable Documents The following publications form a part of this specification to the extent specif
5、ied herein. Unless otherwise indicated, the latest issue of SAE publications shall apply. 2.1.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org. SAE J2197 Hfc-13
6、4a (R-134a) Service Hose Fittings for Automotive Air-Conditioning Service Equipment SAE J2888 R-1234yf Service Hose, Fittings and Couplers for Mobile Refrigerant Systems Service Equipment SAE J2791 HFC-134a Refrigerant Electronic Leak Detectors, Minimum Performance Criteria SAE J2913 R-1234yf HFO-12
7、34yf Refrigerant Electronic Leak Detectors, Minimum Performance Criteria _ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitabilit
8、y for any particular use, including any patent infringement arising therefrom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions
9、. Copyright 2015 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCU
10、MENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/J2970_20
11、1503 SAE INTERNATIONAL J2970 Revised MAR2015 Page 2 of 15 SAE J2670 Stability and Compatibility Criteria for Additives and Flushing Materials Intended for Aftermarket Use in R-134a (HFC-134a) and R-1234yf (HFO-1234yf) Vehicle Air-Conditioning Systems SAE J2911 Procedure for Certification that Requir
12、ements for Mobile Air Conditioning System Components, Service Equipment and Service Technician Training Meet SAE J Standards 3. GENERAL DESCRIPTION AND OPERATING INSTRUCTIONS 3.1 The tracer gas detector shall be suitable for use in safely detecting the tracer gas following recovery of refrigerant fr
13、om the system with equipment that meets SAE J2788 (R-134a) or SAE J2810 (R-134a), SAE J2843 (R-1234yf), SAE J2851 (contaminated systems) or other recovery equipment meeting SAE standards published after this standard. 3.2 The tracer gas shall be suitable for use at temperatures of 15-49 C. (59 to 12
14、0 F.) and have the following characteristics: 3.2.1 It shall meet the commodity specifications of the Compressed Gas Association. 3.2.2 It shall be non-flammable. 3.2.3 It shall be removable from the mobile air conditioning system with ordinary A/C shop equipment, and/or self-release from the system
15、, leaving no residue, in less than 30 minutes. (Note: the tracer gas should not be recovered into the tank of SAE J2788 or SAE J2843 Recovery/Recycling/Recharging equipment. When releasing, care should be taken so the background level of the tracer gas is not increased which may impact further leak
16、detection.) 3.2.4 The pressure required for proper leak detection shall be less than 1.1 MPa (160 psig). 3.2.5 The safety and chemical compatibility of the tracer gas must cover the possibility of a mixture of up to 20% of the system refrigerant from incomplete recovery. Reference SAE J2670 for exam
17、ple test methods. The method of demonstrating compatibility with R-1234yf and R-134a is left to the discretion of the manufacturer/marketer or the test lab, but shall be described with supporting data, as an addendum to the comments section. 3.3 The tracer gas detector shall be tested to meet the pe
18、rformance specifications of this standard by an independent testing facility as defined in SAE J2911, and in accordance with the procedures set forth in SAE J2911. The independent testing facility shall maintain all documentation related to its testing, including calibration and maintenance data for
19、 its equipment, for a period of five years following the final production test of the specific detector. 3.3.1 The manufacturer may state certification of compliance with this Standard (including use of any labeling) only after meeting the requirements in SAE J2911 “Procedure for Certification That
20、Requirements for Mobile Air Conditioning System Components, Service Equipment and Service Technicians Meet SAE J Standards”. See Appendix B. 3.4 If it complies, the detector shall carry a label that states “Design certified by (name of testing laboratory) to meet SAE J2970 with (type of tracer gas,
21、such as 95% nitrogen/5% hydrogen) at (tracer gas test pressure)“ with lettering in bold face type at least 3 mm high. 3.5 If it fails to comply, the detector may be retested subject to the limits of Section 11. If a detector fails beyond the retest limits of Section 11, it shall be retested only aft
22、er the manufacturer/marketer has documented design or process changes made to correct the failure and provided this data to the testing laboratory. A detector must pass the procedures in Sections 7, 8. A failure in either or both of those sections requires a complete retest. The detector also must m
23、eet the requirements of Section 10, passing the no-false-triggering requirement for transmission oil and engine oil (Nos. 13 and 14) and clearing within 20 s after a permitted false-trigger. 3.6 The tracer gas detector shall be suitable for use in an automotive service garage and operate in ambient
24、temperatures of 15 to 49 C (59 to 120 F). SAE INTERNATIONAL J2970 Revised MAR2015 Page 3 of 15 3.7 The tracer gas detector shall be capable of identifying leak rates equivalent to 4 g/year (0.15 oz/year) and 7 g/year (0.25 oz/year) of refrigerant R-134a or R-1234yf when tested using calibrated leak
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ29702015MINIMUMPERFORMANCEREQUIREMENTSFORNONREFRIGERANTTRACERGASSESANDELECTRONICTRACERGASLEAKDETECTORSPDF

链接地址:http://www.mydoc123.com/p-1027735.html