SAE J 2384-2012 Air Dryer Test Procedure《空气干燥剂试验规程》.pdf
《SAE J 2384-2012 Air Dryer Test Procedure《空气干燥剂试验规程》.pdf》由会员分享,可在线阅读,更多相关《SAE J 2384-2012 Air Dryer Test Procedure《空气干燥剂试验规程》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions.Copyright 2012 SAE International All rights reserved. No part of this pub
3、lication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970
4、(outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/J2384_201211SURFACEVEHICLERECOMMENDEDPRACTICEJ2384 NOV2012 Issued 1999-08Revised 201
5、2-11 Superseding J2384 JAN2006 Air Dryer Test Procedure RATIONALEMinor changes have been made in this five year review to cover new air dryer products that are now available in the market. 1. SCOPE This SAE Recommended Practice establishes uniform Test Procedures for desiccant Air Dryers used in veh
6、icles with compressed air systems per SAE J2383. Continuous flow desiccant Air Dryers are excluded from the scope of this document.2. REFERENCES 2.1 Applicable Documents The following publications form a part of this specification to the extent specified herein. Unless otherwise indicated, the lates
7、t issue of SAE publications shall apply. 2.1.1 SAE Publication Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org.SAE J2383 Air Dryer Installation Procedure SAE J2721 Recommended Co
8、rrosion Test Methods For Commercial Vehicle Components 2.1.2 ASTM Publication Available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, Tel: 610-832-9585, www.astm.orgASTM B 117 Standard Test Method of Salt Spray (Fog) Testing SAE J2384 Revised NOV201
9、2 Page 2 of 7 3. DEFINITIONS Refer to SAE J2383 4. INSTRUMENTATION AND EQUIPMENT 4.1 Devices to measure temperature, 1.8 C (3 F). 4.2 Devices to measure pressure, 2% of indicated value. 4.3 A device to measure flow rate, 2% of indicated value. 4.4 A device to measure time, 0.5 s. 4.5 A device to mea
10、sure voltage, 2% of indicated value.4.6 A device to measure amperage, 2% of indicated value. 4.7 A device to control ambient temperature, 1.8 C (3 F). 4.8 A device(s) to heat and saturate air. 4.9 A device to measure dew point temperatures, 0.6 C (1 F). 4.10 A device to measure air leakage, 2% of in
11、dicated value. 4.11 A device to record or count cycles. 4.12 A 1/2 inch NPT pipe plug with a 1.5 mm 0.1 mm (0.06 in 0.004 in) orifice or equivalent. 4.13 Pressure reservoirs of 32.8, 49.2, and 65.6 L 2 L (2000, 3000, and 4000 in3 120 in3).4.14 A salt spray test unit capable of ASTM B 117. 4.15 A vib
12、ration test unit capable of controlling frequency sweeps and g loading. 5. AIR DRYER TEST PROCEDURES 5.1 Air Dryer Operation 5.1.1 Test Conditions Unless otherwise stated, test parameters will be as follows: a. Ambient Temp; 19 to 25 C (67 to 77 F) b. Mounting; As in Service c. Ambient Air Flow; non
13、ed. System Pressure; 9.0 to 9.7 bar (130 to 140 psig) e. Flow Rate; 455 to 510 slpm (16 to 18 scfm) SAE J2384 Revised NOV2012 Page 3 of 7 5.1.2 Pressure Relief Operation With the Outlet Port plugged and no pressure at the Control Port, apply increasing pressure to the Inlet Port at 0.7 to 1 bar/s (1
14、0 to 15 psi/s). Record the pressure at which the Inlet Port Pressure is relieved. Decrease the pressure at the Inlet Port at the rate of 0.7 to 1 bar/s (10 to 15 psi/s). Record the Inlet Port pressure at which the relief function closes (ifprovided).5.1.3 Turbo Cut-off Valve Operation With the Outle
15、t Port plugged and System Pressure at the Control Port, increase the pressure at the Inlet Port from 0 to System Pressure in 1 bar (15 psi) increments. Record the pressure at which the Inlet Port air leakage exceeds 100 sccm. 5.1.4 Regeneration Valve Operation (for System Purge Dryers Only) With the
16、 dryer Outlet Port piped to a 65 L 1 L (4000 in3 60 in3) reservoir, increase the pressure at the dryer Inlet Port to System Pressure. Apply System Pressure to the Control Port and record the pressure drop in the reservoir. Repeat with a 50 L 1 L (3000 in3 60 in3) reservoir in place of the 65 L reser
17、voir. 5.1.5 Heater and Thermostat Operation With the manufacturers specified voltage 1 V applied to the heater connection, record the heater wattage draw versus ambient temperature in 10 C (18 F) decreasing increments over the full range of the heater performance. Repeat for increasing temperature i
18、ncrements. 5.2 Dryer Performance 5.2.1 Pressure Drop During Charge With air flowing at 140, 280, and 420 slpm 10 slpm (5, 10, and 15 scfm 0.3 scfm) through the dryer and 8.3 bar 0.1 bar (120 psig 2 psig) maintained at the Outlet Port, record the difference in pressure between the Inlet and Outlet Po
19、rts. 5.2.2 Flow Capacity With 1.4 bar 0.1 bar (20 psig 1 psig) applied at the Inlet Port and the Outlet Port open, record the flow rate of air through the dryer. 5.2.3 Dryer Capacity Supply the dryer with air at 71 C 2 C (160 F 3 F), 340 slpm 10 slpm (12 scfm 0.3 scfm), and 97 to 100% RH. Connect th
20、e dryer Outlet Port to a test system as described in Figure 1 or equivalent. Cycle the air pressure in the test system through a 1.4 bar 0.1 bar (20 psig 1 psig) range at pressures between 6.8 to 8.4 bar (98 to 122 psig). The unload cycle time is to be 2 times greater than the load cycle time 1 s, f
21、or a 33% duty cycle. Cycle until the Dew Point Temperature of the air in the reservoirs has stabilized. Record the test system reservoir volume and the reservoir air DPD22, where DPD22 is the Dew Point Depression assuming the ambient temperature is 22 C (72 F). This assumption ignores the minor erro
22、r that will occur due to the actual ambient which is to be controlled between 19 to 25 C (67 to 77 F). Then increase the reservoir volume and repeat. Continue to increase the reservoir volume and repeat until the reservoir DPD22 is less than 17 C (30 F). Calculate the volume of air treated per cycle
23、 at which the reservoir air is at 17 C (30 F) DPD22. Then, for System Purge Air Dryers, subtract the purge volume. The resulting volume is the Dryer Capacity, expressed as Standard liters (scf). SAE J2384 Revised NOV2012 Page 4 of 7 FIGURE 1 - TEST SYSTEM Note that in the test system of Figure 1, th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ23842012AIRDRYERTESTPROCEDURE 空气 干燥剂 试验 规程 PDF

链接地址:http://www.mydoc123.com/p-1026905.html