SAE J 2297-2013 Ultraviolet Leak Detection Stability and Compatibility Criteria of Fluorescent Refrigerant Leak Detection Dyes for Mobile R-134a and R-1234yf (HFO-1234yf) Air-Condi.pdf
《SAE J 2297-2013 Ultraviolet Leak Detection Stability and Compatibility Criteria of Fluorescent Refrigerant Leak Detection Dyes for Mobile R-134a and R-1234yf (HFO-1234yf) Air-Condi.pdf》由会员分享,可在线阅读,更多相关《SAE J 2297-2013 Ultraviolet Leak Detection Stability and Compatibility Criteria of Fluorescent Refrigerant Leak Detection Dyes for Mobile R-134a and R-1234yf (HFO-1234yf) Air-Condi.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2013 SAE International All rights reserved. No part of this p
3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-497
4、0 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/J2297_201301 , AEROSPACE SURFACE VEHICLE STANDARD J2297 JAN2013 Issued 1996-09 Re
5、vised 2013-01 Superseding J2297 FEB2012 Ultraviolet Leak Detection: Stability and Compatibility Criteria of Fluorescent Refrigerant Leak Detection Dyes for Mobile R-134a and R-1234yf (HFO-1234yf) Air-Conditioning Systems RATIONALE This document is being revised to add the requirements for certificat
6、ion according to SAE J2911. 1. SCOPE This SAE Standard applies to dyes intended to be introduced into a mobile air-conditioning system refrigerant circuit for the purpose of allowing the application of ultraviolet leak detection. In order to label any product(s) they shall meet SAE J2297, and the ce
7、rtification process as described in SAE J2911 must be followed and the documentation described in the appendix shall be submitted to SAE. 1.1 Purpose The purpose of this document is to establish testing and acceptance criteria to evaluate fluorescent leak detection dye stability in, and compatibilit
8、y with, mobile air-conditioning systems. 2. REFERENCES 2.1 Applicable Documents The following publications form a part of this specification to the extent specified herein. Unless otherwise indicated, the latest issue of SAE publications shall apply. 2.1.1 SAE Publications Available from SAE Interna
9、tional, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org. SAE J2298 Ultraviolet Leak Detection: Procedure for Use of Refrigerant Leak Detection Dyes for Service of Mobile Air-Conditioning Systems SAE J2299 Ultravi
10、olet Leak Detection: Performance Requirements for Aftermarket Fluorescent Refrigerant Leak Detection Dye Injection Equipment for Service of Mobile Air-Conditioning Systems SAE J2776 Refrigerant Purity and Container Requirements for New HFC-134a 1,1,1,2 - Tetrafluoroethane Refrigerant Used in Mobile
11、Air-Conditioning Systems SAE J2297 Revised JAN2013 Page 2 of 8 SAE J2844 R-1234yf New Refrigerant Purity and Container Requirements Used in Mobile Air-Conditioning Systems SAE J2911 Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Se
12、rvice Technician Training Meet SAE J Standards 2.1.2 ANSI Publications Available from American National Standards Institute, 25 West 43rd Street, New York, NY 10036-8002, Tel: 212-642-4900, www.ansi.org. ANSI-ASHRAE 97-2007 Sealed Glass Tube Method to Test the Chemical Stability of Material for Use
13、Within Refrigerant Systems ANSI-ASTM D 664-09 Test Method of Acid Number of Petroleum Products by Potentiometric Titration ANSI-ASTM D 3233-93 (2009) Method for Measurement of Extreme Pressure Properties of Fluid Lubricants (Falex Method) 3. SPECIFICATION AND GENERAL DESCRIPTION 3.1 The dye shall be
14、 certified that it meets this specification by a qualified, independent laboratory. The laboratory shall maintain documentation of testing to this specification for each change in formulation certified, including all calibration data and equipment calibration dates for a period of 5 years following
15、the end of the production run for a certified dye. 3.2 The dye package shall be labeled “This Dye Certified to Meet SAE J2297 for R-134a and PAG lubricants“ or “This Dye Certified to Meet SAE J2297 for R-1234yf and PAG lubricants,“ as appropriate, on an exterior surface. A dye package meeting all re
16、quirements of this specification and intended for use in both R-134a and R-1234yf systems with PAG lubricants shall be labeled “This Dye Certified to Meet SAE J2297 for use in R-134a/PAG and R-1234yf/PAG systems.“ 4. USE INSTRUCTIONS The dye manufacturer shall provide use instructions, which shall c
17、onform, to the requirements as defined in SAE J2298. 5. ASSOCIATED EQUIPMENT For aftermarket service addition of a dye, the dye shall be usable via direct addition into an unpressurized system or with an injection device as defined in SAE J2299. 6. TESTING OF FLUORESCENT LEAK DETECTION DYES 6.1 Thes
18、e test procedures and requirements shall be used to determine the stability and the compatibility of a leak detection dye within a mobile air-conditioning system. A dye must meet all of the acceptance criteria for each test to be certified to this specification. 6.2 The same refrigerant-PAG lubrican
19、t combination shall be used in all the tests defined in this specification. 6.2.1 For R-134a applications, the PAG lubricant must be one commonly used in the mobile air-conditioning industry in OEM R-134a systems. 6.2.2 For R-1234yf applications, the PAG lubricant must be one recommended for use in
20、the mobile air-conditioning industry in OEM R-1234yf systems. SAE J2297 Revised JAN2013 Page 3 of 8 6.3 Rank order analysis is to be used as the acceptance criteria for the fluorescent leak detection dyes evaluated to the specifications defined by this document. Rank order analysis shall be defined
21、as ordering both the three control groups and the three test samples numeric results. A test failure is defined as a total separation of the numeric results of the sample and the control groups where the samples results negatively affected the desirable properties of the lubricant. A passed test is
22、defined as having overlapping sets of numeric results of the sample and control groups, or a total separation of the numeric results of the sample and the control groups where the samples results positively affected the desirable properties of the lubricant. 7. STABILITY TESTING 7.1 Stability testin
23、g shall be performed by preparing sealed tubes as per ANSI-ASHRAE 97-1993. These sealed tubes are to contain an equal volume (1 cc) of liquid refrigerant and lubricant sample as well as metal catalysts. 7.1.1 For dyes intended for use in R-134a systems, the refrigerant sample is to be composed of 99
24、% R-134a and 1% R-12. The lubricant sample shall be composed of 1/3 PAG (see 6.2), 1/3 polyolester (POE) and 1/3 mineral oil. The POE and mineral oils shall be chosen from those commonly available in the market for use in mobile air-conditioning systems. Common POE lubricants include Lubrizol 2916 a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ22972013ULTRAVIOLETLEAKDETECTIONSTABILITYANDCOMPATIBILITYCRITERIAOFFLUORESCENTREFRIGERANTLEAKDETECTIONDYESFORMOBILER134AANDR1234YFHFO1234YFAIRCONDIPDF

链接地址:http://www.mydoc123.com/p-1026840.html