SAE J 1409-2011 Air Brake Valves Test Procedure《空气制动阀试验规程》.pdf
《SAE J 1409-2011 Air Brake Valves Test Procedure《空气制动阀试验规程》.pdf》由会员分享,可在线阅读,更多相关《SAE J 1409-2011 Air Brake Valves Test Procedure《空气制动阀试验规程》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2011 SAE International All rights reserved. No part of this publication m
3、ay be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside U
4、SA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedbackon this Technical Report, please visit http:/www.sae.org/technical/standards/J1409_201102SURFACEVEHICLERECOMMENDEDPRACTICEJ1409 FEB2011 Issued 1983-03 Revised 2011-02Supers
5、eding J1409 MAY2004 Air Brake Valves Test Procedure RATIONALE This document has been updated in keeping with the five-year review process. The Supply and Controls Components Committee has approved the addition of vibration testing per Section 11 and a temperature change from 38 C (100 F) to 43.3 C (
6、110 F) in 3.1. 1. SCOPE This SAE Recommended Practice establishes uniform test procedures for air brake systems pneumatic valves with respect to: a. Input-Output Performance b. Leakage Characteristics c. Low Temperature Evaluation d. Elevated Temperature Evaluation e. Corrosion Resistance Evaluation
7、 f. Endurance Testing g. Structural Integrity h. Vibration Testing 1.1 Purpose This document establishes uniform accelerated laboratory test procedures for evaluating comparative performance characteristics of pneumatic valves designed to operate in 931 kPa (135 psi) nominal air brake systems. These
8、 tests are based upon current industry practices. Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SAE J1409 Revised FEB2011 Page 2 of 92. REFERENCES 2.1 Applicable Document The following publications
9、 form a part of this specification to the extent specified herein. Unless otherwise indicated, the latest issue of SAE publications shall apply. 2.1.1 ASTM Publication Available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, Tel: 610-832-9585, www.as
10、tm.org.ASTM B 117 Method of Salt Spray (Fog) Testing 2.2 Related Publications The following publications are provided for information purposes only and are not a required part of this SAE Technical Report.2.2.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA
11、 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org.SAE J1410 Air Brake ValvePerformance Requirements SAE J1859 Test Procedures for Determining Air Brake Valve Input-Output Characteristics 3. GENERAL NOTES 3.1 Temperature Unless otherwise specified, all
12、testing shall be conducted at a temperature of 15.5 to 43.3 C (60 to 110 F), inclusive. 3.2 Mounting All testing shall be conducted with the unit mounted essentially as in service. The actual mounting position for each test shall be recorded. 3.3 Leakage Measurement All leakage rates shall be expres
13、sed in standard cubic centimeters per minute of free (atmospheric) air. Leakage shall be indicative of total valve leakage. Various methods may be utilized, such as pressure drop in a specific volume or by flow meters. 3.4 Pressure Units All pressure units are expressed as gage pressure (that is, ab
14、ove atmospheric pressure), unless otherwise specified. 3.5 Cycle Rate (Endurance Test) All endurance testing shall be done at a rate of 15 to 25 cycles per minute. Faster rates are permitted if no abnormal effects are introduced. Copyright SAE International Provided by IHS under license with SAENot
15、for ResaleNo reproduction or networking permitted without license from IHS-,-,-SAE J1409 Revised FEB2011 Page 3 of 93.6 Supply Air Unless otherwise specified, the supply air shall be clean and dry. 3.7 Testing Sequence Unless otherwise specified, it is not necessary to use the same valve for more th
16、an one test section. 3.8 Multiple Function Valves Valves with multiple functions shall be tested per all applicable subsections of any test section as agreed upon by valve manufacturer and purchaser. 3.9 Delivery Volume (Endurance Test) Delivery volumes for all endurance testing shall be agreed upon
17、 by the valve manufacturer and purchaser. 4. INPUT-OUTPUT PERFORMANCE The test and test procedure for the input-output characteristics shall be determined by the intended design and functions as agreed upon by the valve manufacturer and purchaser. A typical characteristic is the comparison of input
18、pressure, force or actuator position versus output pressure (application and release). 5. LEAKAGE CHARACTERISTICS 5.1 Pilot Operated and Mechanically Actuated Modulating Type Valves 5.1.1 Low Supply Pressure Test (No Delivery Pressure Condition) With the valve in the no delivery pressure position, t
19、he delivery port(s) open to atmosphere, and 103 kPa 34 kPa (15 psi 5 psi) air pressure at the supply port(s), measure and record leakage. NOTE: When necessary, apply control signal to close inlet seat before performing this test, such as in the case of normally open or inverting type valves. 5.1.2 F
20、ull Supply Pressure Test (No Delivery Pressure Condition) Repeat 5.1.1 with 931 kPa 34 kPa (135 psi 5 psi) air pressure at the supply port(s). 5.1.3 Full Supply Pressure Test (Applied Condition) 5.1.3.1 With 931 kPa 34 kPa (135 psi 5 psi) air pressure at the supply port and all unused ports plugged,
21、 actuate the valve to an ascending delivery pressure of 103 kPa 34 kPa (15 psi 5 psi). Measure and record leakage. 5.1.3.2 Repeat 5.1.3.1 with an ascending delivery pressure of 414 kPa 34 kPa (60 psi 5 psi). Measure and record leakage. 5.1.3.3 Repeat 5.1.3.1 with the maximum attainable delivery pres
22、sure. Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SAE J1409 Revised FEB2011 Page 4 of 95.2 Pilot Operated and Mechanically Actuated Non-Modulating Type 5.2.1 Low Supply Pressure Test (No Delivery
23、 Pressure Condition) With the valve in the no delivery pressure position, the delivery port(s) open to atmosphere, and 103 kPa 34 kPa (15 psi 5 psi) air pressure at the supply port(s), measure and record leakage. NOTE: When necessary, apply control signal to close inlet seat before performing this t
24、est such as in the case of normally open or inverting type valves. 5.2.2 Full Supply Pressure Test (No Delivery Pressure Condition) Repeat 5.2.1 with 931 kPa 34 kPa (135 psi 5 psi) air pressure at the supply port(s). 5.2.3 Full Supply Pressure Test (Applied Condition) With 931 kPa 34 kPa (135 psi 5
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ14092011AIRBRAKEVALVESTESTPROCEDURE 空气 制动 试验 规程 PDF

链接地址:http://www.mydoc123.com/p-1026316.html