SAE J 1346-1981 Guide to Manifold Absolute Pressure Transducer Representative Test Method Information Report《歧管绝对压力传感器代表性的测试方法指南的信息报告 1981年6月》.pdf
《SAE J 1346-1981 Guide to Manifold Absolute Pressure Transducer Representative Test Method Information Report《歧管绝对压力传感器代表性的测试方法指南的信息报告 1981年6月》.pdf》由会员分享,可在线阅读,更多相关《SAE J 1346-1981 Guide to Manifold Absolute Pressure Transducer Representative Test Method Information Report《歧管绝对压力传感器代表性的测试方法指南的信息报告 1981年6月》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirelyvoluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefro
2、m, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions.QUESTIONS REGARDING THIS DOCUMENT: (724) 772-8512 FAX: (724) 776-0243TO PLACE A DOCUMENT
3、 ORDER; (724) 776-4970 FAX: (724) 776-0790SAE WEB ADDRESS http:/www.sae.orgCopyright 1981 Society of Automotive Engineers, Inc.All rights reserved. Printed in U.S.A.SURFACEVEHICLE400 Commonwealth Drive, Warrendale, PA 15096-0001INFORMATIONREPORTSubmitted for recognition as an American National Stand
4、ardJ1346ISSUEDJUN81Issued 1981-06GUIDE TO MANIFOLD ABSOLUTE PRESSURE TRANSDUCER REPRESENTATIVE TEST METHODForewordThis Document has not changed other than to put it into the new SAE Technical Standards BoardFormat.This document is intended as a guide for technical personnel of both using and supplie
5、r firms whose duties includespecifying, calibrating, testing, developing, or demonstrating the performance characteristics of Manifold AbsolutePressure (MAP) transducers. By basing users specifications as well as supplier technical advertising andreference literature on this document, or by referenc
6、ing portions thereof, as applicable, a clear understanding ofthe methods used for evaluating or proving performance will be provided. Adhering to the exemplary test methodoutline, terminology, and procedures shown will result in simple, complete test method documents; it will reducedesign time, proc
7、urement lead time, labor, and materials costs. Of major importance will be the reduction ofqualification test lead time and duration resulting from the use of commonly accepted test procedures.The guide may also serve a useful purpose as a general example for test procedures on other types oftransdu
8、cers.The MAP Transducer Representative Test Method has a companion dependent document, SAE J1347, Guide toManifold Absolute Pressure Transducer Representative Specification, which is referenced to it.1. ScopeThis guide is intended to cover test procedures applicable to MAP transducers; it is also ap
9、plicable totransducers such as Barometric (Ambient) Absolute Pressure transducers, Manifold Vacuum transducers, andsimilar pressure transducers used in automotive systems. Although oriented towards active devices (thoseusing internal signal conditioning), it can be applied to passive devices with mi
10、nor modifications.1.1 ValuesThe guide is intended to be general in nature. Specific values for test data are not included in orderto maintain generality. Exemplary values are contained in the Appendix in an attempt to clarify the text. TheSAE does not imply any recommendation regarding these values.
11、2. References2.1 Applicable PublicationsThe following publications form a part of the specification to the extent specifiedherein. Unless otherwise indicated the latest revision of SAE publications shall apply.2.1.1 SAE PUBLICATIONAvailable from SAE, 400 Commonwealth Drive, Warrendale, PA 15006-0001
12、.SAE Recommended Practice J1113a, “Electromagnetic Susceptibility Procedures for VehicleComponents (Except Aircraft)“, 1975SAE J1346 Issued JUN81-2-2.1.2 ANSI PUBLICATIONSAvailable from ANSI, 11 West 42nd Street, New York, NY 10036-8002.ANSI MC 6.11975 (ISA S37.1), Standard, “Electrical Transducer N
13、omenclature and Terminology“,October 1975ANSI MC 6.21975 (ISA S37.3), Standard, “Specifications and Tests for Strain Gage PressureTransducers“, January 1976ANSI MC 6.51976 (ISA S37.6), Standard, “Specifications and Tests of Potentiometric PressureTransducers“, July 1976ANSI B88.11972, Standard, “A G
14、uide for the Dynamic Calibration of Pressure Transducers“, August 19722.1.3 OTHER PUBLICATIONP. S. Lederer, “Methods for Performance-Testing of Electromechanical Pressure Transducers“, NBSTechnical Note 411 (February 1967)3. Test MethodManifold Absolute Pressure Transducer3.1 Qualification Tests3.1.
15、1 INSPECTIONThe transducer shall be inspected visually for mechanical defects, poor finish, and improperidentification markings. The electrical connector shall also be inspected.3.1.2 STANDARD TEST CONDITIONSUnless otherwise specified, all performance test procedures shall beconducted under the foll
16、owing standard test conditions:a. Laboratory Ambient Temperature: a bC1b. Relative Humidity: c d%c. Excitation Voltage: e fV DC (Source impedance g h)d. Output Load: As specified in J1347, paragraph 2.63.1.3 CALIBRATION EQUIPMENTA variable pressure/vacuum source with a minimum range of ppqq kPa (rrs
17、storr), absolute, and a vacuum-pressure gage with an accuracy of tt% of the reading within this range,comprise the static pressure system. The transducer readout equipment shall have an accuracy of uu% ofthe reading. The traceability of these components must be known. A quick-opening-valve-type of d
18、ynamicstep pressure calibrator is also required, with a rise time (1090%) of kk ms or less and a range of at least80% of the transducer range.3.1.3.1 When two instruments ar required to make measurements, the systematic individual instrument tolerancesshall be considered additive. (That is, if resis
19、tance is measured by measuring current and voltage, a 1%measurement requires 0.5% systematic accuracy in each instrument.) If instrument tolerances arestatistically independent, a root-mean-square overall value may be computed as the square root of the sumof the squares of the individual values.3.1.
20、3.2 A variable pressure/vacuum source shall be used that has a range extending above and below the range ofthe transducer to be measured, and not less than 110% of that range.3.1.4 INSTALLATION CHECKSThe transducer shall be connected to the pressure source (manifold) and securedwith the recommended
21、force or torque. The excitation source, signal conditioner, and read-out instrumentshall also be connected to the transducer and turned on.A warm-up time of 1/2 h shall be allowed for the test equipment, prior to energizing the transducer under test.1. The letters referenced in place of numeric valu
22、es are keyed to the Appendix.SAE J1346 Issued JUN81-3-The pressure source, connecting tubing, and transducer system shall pass a leak test: the transducersystem shall be pressurized to i j kPa (absolute) after which the system shall be sealed off from thepressure source. During the next 30 min, the
23、system pressure shall not change by more than k kPa.Alternative leak tests may be specified.3.1.5 INITIAL STATIC CALIBRATIONSThe transducer shall be energized for vv min, after which the initial calibrationshall be performed.The transducer output shall be recorded at standard test conditions and ele
24、ven input pressures representing20% increments of the range of the transducer in ascending and descending directions (or as otherwisespecified) approaching each pressure slowly in a monotonic manner to avoid overshoot. In the case ofovershoot, the pressure shall be backed up by approximately a 10% i
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ13461981GUIDETOMANIFOLDABSOLUTEPRESSURETRANSDUCERREPRESENTATIVETESTMETHODINFORMATIONREPORT 歧管 绝对

链接地址:http://www.mydoc123.com/p-1026282.html