SAE AS 6070-2015 Aerospace Cable High Speed Data Copper.pdf
《SAE AS 6070-2015 Aerospace Cable High Speed Data Copper.pdf》由会员分享,可在线阅读,更多相关《SAE AS 6070-2015 Aerospace Cable High Speed Data Copper.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2015 SAE International All rights reserved. No part of this p
3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-497
4、0 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/AS6070 AEROSPACE STANDARD AS6070 Issued 2015-01 Aerospace Cable, High Speed Data,
5、 Copper RATIONALE Establish a standard for Qualification by Certification of aerospace high speed data cables. 1. SCOPE 1.1 Purpose This standard covers jacketed multi-conductor copper data cables for aerospace usage. 2. REFERENCES 2.1 Applicable Documents The following publications form a part of t
6、his document to the extent specified herein. The latest issue of SAE publications shall apply. The applicable issue of other publications shall be the issue in effect on the date of the purchase order. In the event of conflict between the text of this document and references cited herein, the text o
7、f this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 2.1.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and
8、 Canada) or 724-776-4970 (outside USA), www.sae.org. AS4373 Test Methods for Insulated Electric Wire AS5768 Tool, Stripper, Electrical Insulation, General Specification For AS5768/1 Tool, Stripper, Manually Actuated, Electrical Insulation, Round Wire, Size 10 to 30 AS5768/2 Tool, Stripper, Manually
9、Actuated, Small Grip, Electrical Insulation, Round Wire, Size 16 to 30 AS6070/1 Cable, High Speed Data Quad, 24 AWG Copper Alloy, 100 Ohm, 200 C, Ethernet 10/100 Base T AS6070/2 Cable, 4 Pair 24 AWG Copper Alloy, Shielded, 100 Ohm, 200 C, Ethernet 1000 Base T AS6070/3 Cable, High Speed Data Quad, 24
10、 AWG Copper Alloy, 110 Ohm, 200 C SAE INTERNATIONAL AS6070 Page 2 of 17 AS6070/4 Cable, 4 Pair 24 AWG Copper Alloy, Shielded, 100 Ohm, 150 C, Ethernet 1000 Base T AS9100 Quality Management Systems - Requirements for Aviation, Space and Defense Organizations AS29606 Wire, Electrical, Stranded, Uninsu
11、lated Copper, Copper Alloy, or Aluminum, or Thermocouple Extension, General Specification For 2.1.2 U.S. Government Publications Copies of these documents are available online at http:/quicksearch.dla.mil. MIL-STD-104 Limit for Electrical Insulation Color MIL-STD-202 Test Method Standard - Electroni
12、c and Electrical Component Parts SD6 Provisions Governing Qualification 2.1.3 ASTM Publications Available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, Tel: 610-832-9585, www.astm.org. ASTM B298 Standard Specification for Silver Coated Soft or Annea
13、led Copper Wire ASTM D3032 Hookup Wire Insulation, Standard Methods of Testing ASTM D4566 Standard Test Methods for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable 2.1.4 National Conference of Standards Laboratories (NCSL) Publications Available fro
14、m NCSL International, 2995 Wilderness Place, Suite 107, Boulder, CO 80301, Tel: 303-440-3339, www.ncsli.org. NCSL Z540.3 Requirement for the Calibration of Measuring Test Equipment 2.1.5 Electronic Components Industry Association (ECIA) Publications Available from Electronic Components Industry Asso
15、ciation, 2214 Rock Hill Road, Suite 265, Herndon, VA 20170, Tel: 571-323-0294, www.ecianow.org. ECA EIA-364-108 Impedance, Reflection Coefficient, Return Loss, and VSWR measured in the Time and Frequency Domain Test Procedure for Electronic Connector, Sockets, Cable Assemblies or Interconnect System
16、s 2.1.6 Institute of Electrical and Electronic Engineers (IEEE) Publications Available from IEEE Operations Center, 445 and 501 Hoes Lane, Piscataway, NJ 08854-4141, Tel: 732-981-0060, www.ieee.org. IEEE 1394 Standard for a High Speed Serial Bus SAE INTERNATIONAL AS6070 Page 3 of 17 2.2 Definitions
17、ATTENUATION: The degradation of signal amplitude along a cable length due to losses in the cable. Attenuation (dB) = 20 log (V1/V2). ATTENUATION TO CROSSTALK RATIO-FAR END (ACR-F): (Formally known as EQUAL LEVEL FAR END CROSSTALK, ELFEXT): A measure of far end crosstalk which accounts for the effect
18、s of cable attenuation. BANDWIDTH: The range of electrical frequencies that a transmission line can effectively handle. The maximum data rate for a given system. (See Attenuation to Crosstalk Ratio) CAPACITANCE, MUTUAL: The capacitance between two conductors of a pair with all other conductors and s
19、hield grounded. CAPACITANCE, UNBALANCE: A measure of the inequality of capacitance between conductors of two adjacent pairs. CAPACITANCE, UNBALANCE TO GROUND: A measure of the inequality of capacitance between the ground capacitance of two conductors of a single pair. CATEGORY 5: A 4-pair cable with
20、 transmission characteristics specified up to 100 MHz. CATEGORY 5e: A 4-pair cable with transmission characteristics specified up to 100 MHz. Tests in addition to those for Category 5 are added to ensure the capability to handle Gigabit Ethernet. CHARACTERISTIC IMPEDANCE: The measure of a transmissi
21、on lines curve fit of the input impedance throughout its length at a specific frequency, or over a swept frequency spectrum. Additionally, characteristic impedance can be defined in the time domain where the rise time of the TDR pulse is defined. COMMON MODE VOLTAGE: In a differential system, the un
22、wanted voltage between each input connection and ground that is added to the voltage of each original signal. CROSSTALK: The noise induced into a passive pair by an active pair measured in dB. Crosstalk measured from the near end is “NEXT” and from the far end is “FEXT”. DELAY SKEW: The difference i
23、n propagation delay between the slowest and fastest pairs in a cable. DIFFERENTIAL IMPEDANCE: The impedance between the inverting and non-inverting input terminals of a differential amplifier. DIRECT CURRENT RESISTANCE (DCR) UNBALANCE: The percent difference of DCR between the two conductors of any
24、pair compared to the others. FAR END CROSSTALK (FEXT): The noise induced into a passive pair by an active pair and measured at the far end. GIGABIT Ethernet: Ethernet networking that supports a data rate of 1 Gigabit per second. IMPEDANCE: The complex opposition to current flow in a transmission lin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS60702015AEROSPACECABLEHIGHSPEEDDATACOPPERPDF

链接地址:http://www.mydoc123.com/p-1025067.html